For Hiden Analytical we quote quadrupole mass spectrometers from the QGA 2.0, HPR-20, RGA series, HAL 101X RC and EQP families; for a quotation we need the gases to be analysed, the sampling pressure and the required mass range.
Headquarters: Warrington, United Kingdom
Who is Hiden Analytical and what does it make?
Hiden Analytical is a British manufacturer of quadrupole mass spectrometers, based in Warrington. A quadrupole mass spectrometer ionises the gases or vapours in a sample and separates the ions by their mass-to-charge ratio; the result is the composition of the mixture, in real time, with detection limits down to parts per billion. The company offers them in several configurations, with mass ranges from 50 to 5000 amu (atomic mass units), and completes the range with secondary ion analysers (SIMS) for surface analysis.
The gas range is divided into three directions. For continuous analysis of gases and vapours there is QGA 2.0, a bench-top instrument under 30 kg, with a range from 0.1 ppm to 100 %, a response time under 300 ms and the possibility of sampling at pressures up to 30 bar, and the HPR-20 family, where the sample evolves from thermal equipment through a heated quartz capillary. For process vacuum there is the RGA series, with mass ranges of 50, 100, 200, 300 and 510 amu, and special versions, for example HAL 101X RC, with the electronics up to 140 m from the sensor, for radiation environments. For plasma, the EQP series measures ions by both mass and energy, up to 1000 eV.
Industrial applications include green hydrogen, biogas, carbon capture, monitoring of fermentation gases, gas purity analysis, glove box control and vacuum diagnostics in thin-film deposition lines. MASsoft Professional software controls the instrument over USB 2.0, RS232 or Ethernet, and QGAsoft calculates concentrations for up to 32 species.
What do we supply from the Hiden Analytical range?
| Product | Description |
|---|---|
| QGA 2.0 | Bench-top mass spectrometer for quantitative analysis of gases and vapours in real time. Dynamic range from 0.1 ppm to 100 %, up to 1000 measurements per second, repeatability under ±2 % relative, a vacuum system compatible with hydrogen and inlets for sampling up to 30 bar. |
| HPR-20 R&D | System for gases and vapours evolving from samples in thermal equipment, with mass ranges of 200, 300, 500 or 1000 amu, a heated quartz capillary and a detection limit of 5 ppb. It is used in thermal analysis, catalysts, fuel cells and biogas. |
| RGA series and HAL 101X RC | Residual gas analysers for vacuum chambers, with mass ranges of 50, 100, 200, 300 and 510 amu, used for leak checking, outgassing, bake-out cycles and process contaminants. HAL 101X RC, with the 100 amu range, has the control unit up to 140 m from the sensor. |
| EQP plasma series | Mass and energy spectrometers for plasma ions: EQP-6, EQP-9 and EQP-20, with a 45° energy analyser up to 1000 eV. They are used for plasma characterisation in HiPIMS deposition, etching and diamond-like carbon layers. |
Why Hiden Analytical?
- QGA 2.0 for gases and vapours — a range from 0.1 ppm to 100 %, response time under 300 ms, so a rapidly changing process can be followed
- Sampling from ambient pressure up to 30 bar — inlet accessories for pipes and reactors, not only for vacuum
- Mass range from 50 to 510 amu in the RGA series — the same family covers a routine vacuum check and a trace analysis
- HAL 101X RC with the electronics up to 140 m away — gas monitoring in radiation environments, without shielding the electronics
- Unified MASsoft Professional software — control over USB 2.0, RS232 or Ethernet and integration with automation through OPC drivers
Which Hiden Analytical codes and series are requested most often?
| Code | Description |
|---|---|
| QGA 2.0 | Bench-top gas analyser, 0.1 ppm–100 % |
| HPR-20 R&D | System for gases evolved from samples, 200–1000 amu |
| HPR-20 EGA | HPR-20 version for analysis of gases evolved from samples |
| HPR-20 OEMS | HPR-20 version for online electrochemical mass spectrometry |
| HPR-40 MIMS | System for dissolved gases and fermentation |
| HPR-40 DEMS | System for electrochemical mass spectrometry |
| pQA | Portable quadrupole analyser |
| RGA Series | Residual gas analysers, 50–510 amu |
| HAL 101X RC | Remote residual gas analyser, 100 amu |
| HALO 201 MBE | Residual gas analyser for molecular beam epitaxy |
| EQP-6 | Plasma mass and energy spectrometer, 300 or 510 amu |
| EQP-9 | Plasma mass and energy spectrometer, up to 5000 amu |
| EQP-20 | Spectrometer for hydrogen plasma, 20 or 200 amu |
| LAS | Automatic leak testing system with mass spectrometer |
| MASsoft Professional | Control software for Hiden instruments |
Where is Hiden Analytical equipment used?
- Energy and hydrogen — gas analysis in green hydrogen production and carbon capture
- Chemicals and catalysts — gases evolved in thermal analysis and catalyst testing
- Biogas and fermentation — monitoring of process gases from bioreactors and digesters
- Thin films and semiconductors — vacuum and plasma control on deposition lines
- Vacuum and nuclear research — residual gas analysis in chambers with radiation, including fusion facilities
How do we supply Hiden Analytical in Romania?
We can quote Hiden mass spectrometers from the QGA, HPR, RGA, EQP and LAS families, as well as MASsoft Professional software. We supply Hiden Analytical to order, usually in 1–4 weeks; for special configurations, depending on the specification, the lead time can be longer, and the exact date is confirmed in the quotation. For a correct request, send the gases or vapours to be analysed, the concentration range, the pressure at the sampling point, the required mass range and whether the instrument is integrated into a vacuum system or into thermal equipment.
Whether a mixture whose components have very close masses can be separated on a given model is established from the list of components and their concentrations.
Frequently asked questions about Hiden Analytical
What does Hiden Analytical make?
Hiden makes quadrupole mass spectrometers for gases, vapours and plasma in the United Kingdom, residual gas analysers for vacuum, leak testing systems and SIMS surface analysers. The instruments measure the composition of mixtures in real time, from percentages down to parts per billion.
How do I choose between QGA 2.0 and an HPR-20 system?
QGA 2.0 is chosen for a gas or vapour flowing continuously through a sampling point, from ambient pressure up to 30 bar. HPR-20 is chosen when the gas evolves from a sample in thermal equipment. Send us the process type, the gases to be monitored and the concentration range.
Do you supply Hiden instruments in Romania and how fast?
Yes, we supply Hiden Analytical to order, usually in 1–4 weeks. Depending on the specification, the lead time can be longer; we confirm the exact date in the quotation, after we establish the mass range, the sampling inlet and the software.
What mass range should I choose for an RGA analyser?
The range is chosen according to the mass of the species to be monitored, and the RGA series has options of 50, 100, 200, 300 and 510 amu. For an ordinary vacuum check, start from the usual gases, water, nitrogen, oxygen or hydrogen. Tell us which gases or vapours you are monitoring and the pressure in the chamber, so that we can propose the configuration.
What data do I need to send for a quotation on an HPR-20 or QGA system?
Send the list of gases to be measured and the estimated concentrations, the pressure and temperature at the sampling point, the available flow, the required interface (USB, RS232, Ethernet or OPC) and whether the instrument connects to existing thermal equipment, with its model.
How do I request a Hiden Analytical quotation?
Send the Hiden Analytical code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Hiden Analytical (manufacturer documentation)