LECO supplier in Romania
For LECO we offer the CS744 and CS844 carbon and sulphur analysers, the oxygen, nitrogen and hydrogen analysers from the 736 and 836 series, the AC500 and AC600 calorimeters, the TGA801 analyser and the GDS900 and GDS950 spectrometers, based on the elements to be determined and the sample type.
Founded in 1936 · Headquarters: St. Joseph, Michigan, USA
Who is LECO and what does it make?
LECO is an American manufacturer of laboratory analytical instruments, headquartered in St. Joseph, Michigan, active since 1936. The programme for industry has three lines: elemental analysis by combustion or inert gas fusion (carbon, sulphur, oxygen, nitrogen, hydrogen), thermal analysis (calorimeters and thermogravimetric analysers) and glow discharge optical emission spectrometers (GDS). Metallurgy, energy and the construction materials industry use them to control the composition and quality of batches.
The CS744 and CS844 carbon and sulphur analysers burn the sample in a high-frequency induction furnace and measure by infrared; CS844 has dual detectors, for wider concentration ranges. The 736 and 836 series determine oxygen and nitrogen in metals by inert gas fusion, and the 836 series adds hydrogen in the same cycle. The AC500 and AC600 isoperibol calorimeters measure the gross calorific value of solid and liquid fuels, and TGA801 determines moisture, ash, volatile matter and loss on ignition on up to 19 samples in a batch. The GDS900 (direct current discharge) and GDS950 (direct current and radio frequency, hence also non-conductive materials) spectrometers analyse both the bulk composition and the depth profile of coatings.
These instruments are found in the laboratories of steelworks and foundries, at galvanizing lines, at installations that analyse coal or biomass, at cement and construction materials plants and in materials research laboratories. The choice depends on the element sought, the concentration range, the sample type and the number of samples per shift, which is why the offer starts from the elements to be determined and the standard method required.
What do we supply from the LECO range?
| Product | Description |
|---|---|
| CS744 and CS844 | Carbon and sulphur analysers for inorganic materials, with a high-frequency induction furnace and integrated oxygen lance, infrared detection and automatic cleaning options; CS844 has dual detectors for wider ranges. |
| 736 and 836 series | Inert gas fusion analysers for oxygen and nitrogen in metals and alloys, with infrared and thermal conductivity detectors, cycles of about 3 minutes and a 20-position loader; the 836 series adds hydrogen. |
| GDS900 and GDS950 | Glow discharge optical emission spectrometers for bulk analysis and depth composition profile: GDS900 with a direct current source for routine control, GDS950 with a dual source for conductive and non-conductive materials. |
| AC500, AC600 and TGA801 | The AC500 and AC600 isoperibol calorimeters determine the gross calorific value of solid and liquid fuels; the TGA801 thermogravimetric analyser measures moisture, ash and volatile matter on up to 19 samples, with a 0.0001 g balance. |
Why LECO?
- Induction combustion and infrared detection — CS744 and CS844 determine carbon and sulphur in metals and inorganic materials, and CS844 has dual detectors for wide ranges
- Oxygen, nitrogen and hydrogen in a single cycle — the 836 series adds hydrogen to the determination of oxygen and nitrogen, with an automatic 20-position loader
- Bulk composition and depth profile — GDS900 and GDS950 evaluate the coating and the substrate in a single analysis, using ISO methods for GD-OES
- Direct current and radio frequency sources on GDS950 — extend the analysis to glass, ceramics and non-conductive coatings
- Thermal analysis for fuels — AC500 and AC600 for gross calorific value, TGA801 for moisture, ash and volatile matter on batches of up to 19 samples
Which LECO codes and series are requested most often?
| Code | Description |
|---|---|
| CS744 | Induction carbon and sulphur analyser, one IR detector |
| CS844 | Carbon and sulphur analyser with dual detectors |
| 736 Series | Oxygen and nitrogen analyser by inert gas fusion |
| 836 Series | Simultaneous oxygen, nitrogen and hydrogen analyser |
| CM812 | Total carbon and moisture determination |
| 832 Series | Carbon and sulphur in fuels and organic materials |
| 828 Series | Carbon, hydrogen, nitrogen and sulphur analyser, 30 samples |
| 928 Series | Version 828 with horizontal furnace and macro samples up to 3 g |
| AC500 | Isoperibol calorimeter with classic calculation modes |
| AC600 | Isoperibol calorimeter with thermodynamic modelling |
| TGA801 | Thermogravimetric analyser for moisture, ash, volatile matter |
| GDS900 | Glow discharge spectrometer, direct current |
| GDS950 | Glow discharge spectrometer, direct current and RF |
Where is LECO equipment used?
- Steelworks and foundries — carbon, sulphur, oxygen, nitrogen and hydrogen in metals and alloys
- Galvanizing and coatings — depth composition profile for zinc layers and other treatments
- Energy and solid fuels — calorific value, moisture and ash in coal and biomass
- Cement and construction materials — moisture, volatile matter and loss on ignition
- Battery materials and research laboratories — elemental analysis of new materials
How do we supply LECO in Romania?
We can offer LECO elemental analysers, calorimeters, thermogravimetric analysers and GDS spectrometers, supplied to order. The lead time is usually 1–4 weeks to order, and depending on the specification it may be longer, especially for spectrometers and automation accessories. For a quotation, send us the elements to be determined (C, S, O, N, H or bulk composition), the concentration range, the sample type, the number of samples per day, the standard method required and the model of the old instrument, if you are replacing one. The exact lead time is confirmed in the quotation.
The suitable model follows from the list of elements, the concentration range and the standard method required.
Frequently asked questions about LECO
What does LECO make?
LECO, headquartered in St. Joseph (Michigan), makes elemental analysers for carbon, sulphur, oxygen, nitrogen and hydrogen, calorimeters and thermogravimetric analysers, glow discharge spectrometers and metallography equipment. The instruments are used to control the composition of metals, fuels and construction materials.
How do I choose between GDS900 and GDS950?
GDS900 has a direct current source and covers the routine analysis of metals and conductive coatings. GDS950 has a dual source, direct current and radio frequency, so it can also analyse glass, ceramics or non-conductive layers. Tell us the sample materials and whether you need a depth profile.
How soon can you bring a LECO analyser to Romania?
The analysers are brought in to order, usually in 1–4 weeks; depending on the specification, the lead time may be longer, for example for spectrometers or automatic loaders. We confirm it in the quotation, once we receive the configuration you want.
What do you check when I replace an older carbon and sulphur analyser?
We check the instrument model and series, the concentration range, the sample type and the accessories used, such as crucibles and the loader. CS744 and CS844 have the same type of furnace, but CS844 has dual detectors; equivalence is established only after comparing these data.
What should I send for a quotation on an oxygen, nitrogen and hydrogen analyser?
Send the sample material (steel or another alloy), the expected range for each element, the number of samples per day and whether you need hydrogen, that is the 836 series. It also matters whether you work with a 20-position automatic loader or manually.
How do I request a LECO quotation?
Send the LECO code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: LECO Corporation (manufacturer documentation)