Perma Pure supplier in Romania
For Perma Pure we quote MD, MD-700, PD and BE dryers, GASS 2040 and Mini GASS 1228 systems, Baldwin coolers and AS scrubbers; we need the sample flow, the dew point wanted, the gas composition and the analyser used.
Who is Perma Pure and what does it make?
Perma Pure makes gas dryers with Nafion tubes and sample conditioning systems for gas analysers. The problem it solves is water vapour in the sample: on the way between the stack or pipe and the analyser it condenses, dissolves the components to be measured and gives wrong readings. A Nafion dryer transfers water vapour selectively through the tube wall into a dry purge gas, in counter-current, while the components analysed stay in the sample.
Dryers are chosen by flow and dew point. The MD series has a single Nafion tube, with outside diameters of 0.050, 0.070 and 0.110 inches, reaches a dew point of -40 °C and suits flows of up to 4 l/min. The MD-700 uses a 17 mm tube, in lengths of 6 to 48 inches, for samples with particles, without heating the sample. The PD series groups several tubes in parallel for high flows and goes down to -45 °C. The BE braided exchangers balance the humidity of the sample with the ambient air, without purge and without a power supply. For complete installations there are the GASS 2040 systems, for flows of up to 25 l/min and humidity above 50 %, and the Mini GASS 1228, for flows of up to 5 l/min, plus the Hybrid and Baldwin coolers and the AS series ammonia scrubbers.
Typical applications are continuous emission monitoring systems (CEMS), process analysers on stacks and pipes, and research instruments. The quotation starts from the dryer code, for replacements, or from the flow, the dew point wanted, the sample composition and the temperature, for new installations.
What do we supply from the Perma Pure range?
| Product | Description |
|---|---|
| Monotube (MD) and MD-700 dryers | The MD-Series has a single Nafion tube and dries the sample to a dew point of -40 °C at flows of up to 4 l/min. The MD-700 has a 17 mm tube in lengths of 6–48 inches, in grounded stainless steel, for samples with particles, and can be used with reflux purge. |
| Polytube (PD) dryers and BE exchangers | The PD-Series combines several Nafion tubes in one housing, for high flows in emission monitoring and in small processes. The BE-Series Braided Exchanger dries or humidifies a gas by equilibration with the surrounding atmosphere, without purge, without power and without losing components. |
| GASS 2040 and Mini GASS 1228 systems | The GASS 2040 conditions samples with a high flow and humidity above 50 %, with a 0.1 µm coalescing filter, an ammonia scrubber and a Nafion dryer, in a NEMA 4X enclosure. The Mini GASS 1228 is the compact version, for flows of up to 5 l/min, with a heated filter probe. |
| Hybrid and Baldwin coolers, AS scrubbers | The Hybrid Sample Gas Cooler has an IP65 enclosure and works at 4–55 °C. The Baldwin is a digital thermoelectric cooler, with a PID controller, on one or two streams. The AS-200-08 ammonia scrubbers come in PS, PSH, SS and SSH versions, with or without a heating jacket. |
Why Perma Pure?
- Selective drying — Nafion tubes remove water vapour without removing the components analysed from the sample
- Several dryer families — MD for low flows, MD-700 for samples with particles, PD for high flows, BE without purge and without power
- Complete stack systems — the GASS 2040 has three temperature-controlled zones, a coalescing filter and a NEMA 4X enclosure, with possible mounting on the stack flange
- Thermoelectric coolers — Baldwin with a Peltier element, a PID controller and water leak sensors to protect the analyser
- Ammonia scrubbers — the AS series, in a polysulfone or 316 stainless steel enclosure, with heated versions, for samples with ammonia
Which Perma Pure codes and series are requested most often?
| Code | Description |
|---|---|
| MD-050 | Dryer with a single 0.050 inch Nafion tube |
| MD-070 | Dryer with a single 0.070 inch Nafion tube |
| MD-110 | Dryer with a single 0.110 inch Nafion tube |
| MD-700 | Dryer with a 17 mm Nafion tube, for samples with particles |
| PD-Series | Multi-tube dryer, for high flows, dew point down to -45 °C |
| BE-Series | Braided exchanger, no purge |
| BE-HP | High-pressure braided exchanger |
| GASS 2040 | Sample conditioning system, up to 25 l/min |
| Mini GASS 1228 | Compact conditioning system, up to 5 l/min |
| Hybrid Sample Gas Cooler | Sample cooler, IP65 enclosure |
| Baldwin Digital Cooler | Thermoelectric cooler with PID controller |
| AS-200-08-PS | Ammonia scrubber, polysulfone enclosure |
| AS-200-08-SS | 316 stainless steel ammonia scrubber |
| AS-200-08-PSH / SSH | Ammonia scrubbers with heating jacket |
Where is Perma Pure equipment used?
- Emission monitoring — sample conditioning for CEMS systems on stacks
- Process gas analysis — dryers upstream of the analysers, without losing components
- Power plants and combustion installations — hot, wet samples, with acid or ammonia
- Research and environmental laboratories — humidity dosing and drying of gas samples
How do we supply Perma Pure in Romania?
We can quote Perma Pure dryers from the MD, MD-700, PD and BE series, GASS 2040 and Mini GASS 1228 conditioning systems, coolers and AS ammonia scrubbers. Supplied to order, usually in 1–4 weeks; for complete systems, depending on the specification, the lead time can be longer. For a correct quotation, send us the sample flow, the dew point wanted, the composition and temperature of the gas, the presence of acid or ammonia, the analyser used and the place of installation. For an existing dryer, add the code from the label.
The right dryer or GASS system is established from the flow, the temperature and the composition of the sample, including the acid or ammonia content.
Frequently asked questions about Perma Pure
What does Perma Pure make?
Perma Pure makes gas dryers with Nafion tubes, braided exchangers, sample coolers, ammonia scrubbers and complete sample conditioning systems for emission and process analysers. The principle is the selective transfer of water vapour, without losing the components analysed.
How do I choose between an MD, PD or MD-700 dryer?
The MD suits low flows, up to 4 l/min, the PD high flows, and the MD-700 samples with particles, where heating the sample is not wanted. The dew point required and the purge gas available also matter. Send us the flow, the temperature and the composition of the sample, and we propose the series.
Can you supply Perma Pure products in Romania, and how fast?
Yes, supplied to order, usually in 1–4 weeks; items can ship in 24–72 h when the item is in stock, locally or at the supplier. Complete GASS systems may take longer, depending on the specification; we confirm the exact lead time in the quotation.
Can an old Perma Pure dryer be replaced with a current series?
It depends on the series, the length, the connections and the purge gas. Equivalence is checked on the data, not by name; send the code from the label, a photo and the working flow, and we compare the data with the current series and show what can be kept in the same installation.
What information do you need to quote a sample conditioning system?
Send the sample flow, the temperature and pressure of the gas, the moisture content, the presence of acid, ammonia or particles, the dew point required by the analyser, the analyser used, the power supply available and the place of installation, for example directly on the stack flange.
How do I request a Perma Pure quotation?
Send the Perma Pure code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Perma Pure (manufacturer documentation)