ENVEA supplier in Romania
MIR 9000 and MIR FT emission analysers, SM-5 mercury, dust and dioxins
Headquarters: Poissy, France
Who is ENVEA and what does it make?
ENVEA is a French company based in Poissy, established over 45 years ago, in the wake of the acid rain crisis, to build pollution measuring instruments. Today the range is very wide, from particle counters for research to air quality sensors, but for a maintenance or environmental engineer in industry the lines for stack emission monitoring matter first: multi-gas analysers, mercury, dust, dioxins, flow and sample conditioning systems.
The MIR 9000 analyser uses NDIR with a correlation filter and measures up to ten gases simultaneously, including NO, NO2, SO2, CO, HCl and HF, in a dry sample. It has measurement approvals stated in the manufacturer's documentation, and a complete CEMS is usually built around it, with an SEC dryer and the Graphite 52M FID detector for organic compounds. MIR FT is the FTIR version with a hot, wet sample, at 180 °C, for HCl, HF, NH3, NO, N2O, SO2, CO, CH4 and TOC. SM-5 is a mercury analyser with a certification range between 0 and 5 µg/m³, STACK 990 a dust monitor for bag filters, and AMESA-D a continuous sampler for dioxins and furans over periods from four hours to six weeks.
These lines are used at incinerators, cement kilns, thermal power plants, steelworks and chemical plants, where the environmental permit requires continuous monitoring. Selection is made by the gases to be measured, the emission limits, the humidity and temperature of the sample and the certification required, usually QAL 1.
What do we supply from the ENVEA range?
| Product | Description |
|---|---|
| MIR 9000 | NDIR-GFC multi-gas analyser for CEMS, with measurement approvals as per the manufacturer's documentation. It measures up to ten gases in a dry sample, with a paramagnetic cell for O2, in a 19-inch rack version or in a wall-mount housing. |
| MIR FT | FTIR multi-gas analyser, with the approvals mentioned, in a complete cabinet with an industrial PC and eSAM software. It measures hot, wet gases: HCl, HF, NH3, NO, NO2, N2O, SO2, CO, CH4, TOC, H2O, CO2 and O2, with a line heated to 180 °C. |
| SM-5 | Continuous total mercury analyser for stack emissions, with certification ranges from 0–5 to 0–1000 µg/m³, high-temperature conversion with no reagents and no calibrator, with dynamic range switching for emission peaks. |
| STACK 990 and AMESA-D | STACK 990 is an electrodynamic dust monitor, with the approvals mentioned, for low concentrations after bag filters. AMESA-D samples dioxins and furans isokinetically on an XAD-II cartridge, with the approvals mentioned, for incinerators, cement and power plants. |
Why ENVEA?
- MIR 9000 with up to ten gases simultaneously — NO, NO2, SO2, CO, HCl, HF, with automatic interference correction
- Measurement approvals indicated in the manufacturer's technical documentation — for regulated emission monitoring
- MIR FT with a hot, wet sample at 180 °C — measures soluble gases such as HCl, HF and NH3 without sample losses
- SM-5 with 0–5 µg/m³ certification for mercury — a fine range for strict emission limits
- AMESA-D for dioxins — continuous sampling from four hours to six weeks, to EN 1948-1
Which ENVEA codes and series are requested most often?
| Code | Description |
|---|---|
| MIR 9000 | NDIR-GFC multi-gas analyser, with approvals as per the datasheet |
| MIR FT | FTIR multi-gas analyser, hot and wet sample |
| Graphite 52M | FID detector for organic compounds, EN 12619 |
| SM-5 | Total mercury analyser for CEMS |
| UT-3000 | Trace mercury analyser, EN 15852 |
| STACK 990 | Electrodynamic dust monitor, with approvals indicated in the manufacturer's technical documentation |
| AMESA-D | Permanent sampler for dioxins and furans |
| SEC box | Permeation sample dryer for MIR 9000 |
| StackFlow 200 | Flue gas velocity monitor |
| AF22e | SO2 analyser from the e series |
| AC32e | NOx analyser from the e series |
Where is ENVEA equipment used?
- Incinerators and waste-to-energy — MIR 9000, AMESA-D and SM-5 at the stack
- Cement and minerals industry — monitoring of gases and dust in processes
- Thermal power plants — SO2, NOx, CO and dust for emission reporting
- Steelworks and metallurgy — dust after bag filters, with STACK 990
- Chemicals and pharmaceuticals — HCl, HF, NH3 and organic compounds in wet streams
How do we supply ENVEA in Romania?
We can prepare quotations for ENVEA emission analysers: MIR 9000, MIR FT, SM-5, STACK 990 and AMESA-D, as well as for accessories of sampling systems. Equipment is supplied to order; CEMS systems are configured to the installation, so the lead time is usually 1–4 weeks and may be longer. For a correct quotation we need the gases and ranges to be measured, the limits in the permit, the temperature, humidity and dust in the gas, the mounting location and the certification required. For replacements, send the make and model of the current analyser; the configuration is confirmed in the quotation.
The fit of an ENVEA analyser with a sampling line already installed is assessed from its sketch, so compatibility is checked before ordering.
Frequently asked questions about ENVEA
What does ENVEA make?
ENVEA, based in Poissy, makes analysers for industrial emission and air quality monitoring: MIR 9000 and MIR FT for stack gases, SM-5 for mercury, STACK 990 for dust, AMESA-D for dioxins, plus ambient air sensors and research instruments.
How do I choose between the MIR 9000 and the MIR FT for a CEMS?
The MIR 9000 works on a dry sample, with NDIR, for up to ten gases, including HCl and HF. The MIR FT uses FTIR on a hot, wet sample, useful above all for NH3, HCl and other soluble gases. Send us the list of gases, the humidity of the sample and the limits in the permit.
Do you supply ENVEA analysers in Romania, and how quickly?
Yes, analysers are supplied to order. The lead time is usually 1–4 weeks, and complete CEMS systems, with probe and heated line, may need more. The exact lead time is confirmed in the quotation.
Can I replace an existing emission analyser with an ENVEA model?
Replacement depends on the sampling line, the interfaces with the data acquisition system and the certification required. Equivalence is assessed from the data: we need the make and model of the current analyser, the gases and ranges measured and, if there is one, the diagram of the sampling system.
What data do I need to send for a quotation on an SM-5 mercury analyser?
State the expected mercury concentration and the limit in the permit, the temperature and humidity of the gas, the SO2 and HCl content, the duct diameter and whether QAL 1 certification is required. From these data we identify the measuring range and the probe configuration.
How do I request a ENVEA quotation?
Send the ENVEA code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.