COSA Xentaur supplier in Romania
Online Wobbe/BTU calorimeters and HTF dew point transmitters
Who is COSA Xentaur and what does it make?
COSA Xentaur makes, in Houston, Texas, two families of instruments for industrial gases: online calorimeters for fuel gas and humidity instruments with an aluminium oxide sensor, based on its in-house Hyper-Thin-Film (HTF) technology. The calorimeters continuously measure the Wobbe index, calorific value (BTU) and the combustion air requirement index (CARI), exactly the parameters a burner, turbine or furnace depends on when the gas composition changes.
Model 9610 CXc uses the residual oxygen principle: the sample is mixed with dry air in a constant ratio, burned catalytically at 800 °C, and a zirconia cell measures the remaining oxygen; the T90 response time is under 5 seconds for the Wobbe index in the basic configuration. Model 9800 CXi uses injection into a flameless combustion furnace at 1000 °C, and returns most of the sample to the process, which reduces hydrocarbon emissions when analysing flare gas.
The other family, the HDT and LPDT dew point transmitters and the XPDM portable instrument, covers the range from −100 °C to +20 °C. These instruments are used in gas combustion in refineries and petrochemicals, at gas compression and drying stations, on gas turbines and in compressed air installations with drying requirements.
What do we supply from the COSA Xentaur range?
| Product | Description |
|---|---|
| 9610 CXc | Online calorimeter for Wobbe, calorific value, heating value and CARI in fuel gas, refinery gas, flare gas, biogas and hydrogen mixtures. It measures the oxygen remaining after catalytic combustion of the sample, with an option of hydrogen integrated in the analyser. |
| 9800 CXi | Calorimeter with injection and a flameless combustion furnace at 1000 °C for flare, refinery gas, natural gas, LNG and hydrogen mixtures. It covers the whole calorific value range without a separate relative density meter. |
| HDT | Dew point transmitter with an HTF aluminium oxide sensor, loop-powered, for −100 °C to +20 °C, used in compressed air, natural gas, hydrogen and industrial gases; it has approvals for explosive atmospheres. |
| XPDM | Portable instrument powered by a 9 V battery, for checking dew point in the field, with a dry storage system that protects the sensor between measurements; accuracy of up to ±3 °C. |
Why COSA Xentaur?
- 9610 CXc calorimeter with a T90 response under 5 seconds for the Wobbe index — useful for adjusting combustion when the fuel gas changes composition
- 9800 CXi with a flameless furnace at 1000 °C — returns most of the sample to the process and limits hydrocarbon emissions in flare gas
- Versions for classified zones for the 9610 CXc, according to the manufacturer's documentation, with IP66 protection
- HTF aluminium oxide sensor — high sensitivity, low drift and insensitivity to temperature variations, for the range −100 °C to +20 °C
- Compact 2-wire loop transmitters (LPDT) and a portable instrument with a dry storage system (XPDM) — fixed monitoring and field checks from the same technology
Which COSA Xentaur codes and series are requested most often?
| Code | Description |
|---|---|
| 9610 CXc | Online Wobbe, BTU and CARI calorimeter with residual oxygen |
| 9800 CXi | Calorimeter with injection, flameless furnace at 1000 °C |
| HDT | Dew point transmitter with HTF sensor, loop-powered |
| HDT-LQ | Transmitter for dissolved water in liquid hydrocarbons |
| LPDT | Compact dew point transmitter, 2-wire loop |
| XDT | Dew point transmitter with alarms and analogue and digital outputs |
| XPDM | Portable dew point instrument, battery-powered |
| ESS | Extractive sampling system for humidity instruments |
| ESS-SCVP | Process humidity analyser with a dedicated sampling system |
Where is COSA Xentaur equipment used?
- Refineries and petrochemicals — calorific value and Wobbe in fuel and flare gas
- Burners, boilers and gas turbines — combustion adjustment by Wobbe index
- Natural gas stations — humidity and dew point to prevent hydrates
- Industrial compressed air — monitoring of dryers, according to the ISO 8573 humidity class
- Liquid hydrocarbons — dissolved water, measured with the HDT-LQ version
How do we supply COSA Xentaur in Romania?
We can quote COSA Xentaur calorimeters, dew point transmitters and portable instruments, plus parts for installed units. The equipment is supplied to order; the lead time is usually 1–4 weeks, and configurations with a sample system, cabinet or classified zone may need more. For a calorimeter we need the gas composition or type (fuel, flare, LNG, hydrogen in a mixture), the calorific value range, the sample pressure and temperature and the zone classification. For humidity: the dew point range, the process gas and the connection. Some items can ship in 24–72 h when the item is in stock, locally or at the supplier, and the precise lead time is set in the quotation.
The interchangeability of a new calorimeter with an old one of another series is confirmed from the mounting data and a compatibility check.
Frequently asked questions about COSA Xentaur
What products does COSA Xentaur make?
Online calorimeters that measure the Wobbe index, calorific value and CARI for fuel and flare gas, plus dew point transmitters, probes and portable instruments with an HTF aluminium oxide sensor. Manufacturing is in Houston, Texas.
How do I choose between the 9610 CXc and the 9800 CXi?
The 9610 CXc measures the oxygen remaining after catalytic combustion at 800 °C and is suited to fuel and flare gas with a fast response. The 9800 CXi burns the sample in injections, without a flame, and returns most of the gas to the process, so it suits cases where hydrocarbon emissions are critical. The gas composition and the emissions requirement help us.
Can you supply COSA Xentaur instruments in Romania, and within what lead time?
Yes, to order; a calorimeter or a dew point transmitter usually arrives in 1–4 weeks. Transmitters and parts can ship in 24–72 h when the item is in stock, locally or at the supplier, but systems with a cabinet for classified zones need a separate lead time.
Can I replace an old dew point transmitter with an HDT or LPDT?
Equivalents are confirmed after checking. Send the old model, the measuring range, the output type, the connection thread and the zone classification, and we check the fit before the quotation.
What data should I send for a calorimeter quotation?
The type of gas and the calorific value range, the sample pressure and temperature, whether there is hydrogen in the mixture, the place of installation (indoor or outdoor), the zone classification and the signals required by the control system or the burner.
How do I request a COSA Xentaur quotation?
Send the COSA Xentaur code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Process Insights (manufacturer documentation)