Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Boreal Laser supplier in Romania

TDL laser gas detectors, GasFinder3, with open path and measuring heads

Founded in 1990 · Headquarters: Edmonton, Canada

Request a quote

Who is Boreal Laser and what does it make?

Boreal Laser is a Canadian manufacturer from Edmonton, founded in April 1990, specialised in gas detection and measurement by tunable diode laser absorption spectroscopy (TDLAS). The GasFinder3 series uses an in-house measurement element, and the measuring head is chosen according to the application: open path head (OPX), remote point probe (RPX), stack or gas duct probe (SDX), extractive cell (EMX), insertable probe (IPX) or in-line probe (ILX). The equipment is installed in more than 47 countries.

What it solves is detection "outside the pipe": a laser beam crosses 5–200 m to a reflector and senses the gas along the path, without depending on a point sensor placed exactly in the way of the gas cloud. The same analyser, with a different measuring head, can measure in a stack, in a pipe or on an extracted sample. The available gases include hydrogen fluoride, CO2, ammonia, methane, CO, hydrochloric acid, hydrogen sulphide, hydrogen cyanide, oxygen, ethylene and acetylene.

Such systems suit refineries and petrochemicals, ammonia and fertiliser plants, gas handling stations and chemical plants with a risk of toxic or flammable gas leaks. The exact model of an existing analyser is identified from the GasFinder3 nameplate.

What do we supply from the Boreal Laser range?

ProductDescription
GasFinder3-MCField-mounted multichannel TDL analyser, configurable with two or four channels, hazardous-area or general-purpose enclosure, analogue output and relay modules.
GasFinder3-MCrRack-mounted multichannel TDL analyser with two, four or eight channels, for control rooms; it connects to GasFinder3 measuring heads via CAT6/5e cable.
GasFinder3-OPPortable open path detector, with a retro-array reflector for paths of 5–500 m, powered at 12–24 V DC or from the mains.
GasFinder Line of Sight (LoS)All-in-one open path laser detector for detecting gas leaks in hazardous industrial applications.

Why Boreal Laser?

  • Open path detection between 5 and 200 m (GasFinder3-OP up to 500 m) — covers a perimeter with one beam, instead of several point sensors
  • GasFinder3-MC and MCr multichannel analyser — two, four or eight channels, with analogue and relay modules configurable for DCS integration
  • Measuring head chosen according to the application — OPX, RPX, SDX, EMX, IPX or ILX, with cables of 5 to 300 m between the head and the analyser
  • Shur-Shot for hydrofluoric acid — dedicated HF detector, with Class I Division 1 certification
  • Wide range of gases — HF, H2S, NH3, CH4, CO, CO2, HCl, HCN, O2, ethylene and acetylene on the same type of platform

Which Boreal Laser codes and series are requested most often?

CodeDescription
GasFinder3-MCField multichannel TDL analyser, 2 or 4 channels
GasFinder3-MCrRack multichannel TDL analyser, 2, 4 or 8 channels
GasFinder3-OPPortable open path detector
GasFinder LoSAll-in-one open path laser detector
OPXOpen path measuring head (Open Path)
RPXRemote point probe (Remote Point)
SDXStack or gas duct probe (Stack/Duct)
EMXCell for extractive measurement
IPXInsertable probe
ILXIn-line probe
Shur-ShotHydrofluoric acid detector with 4–20 mA output
GasCartTransportable measurement system

Where is Boreal Laser equipment used?

  • Refineries and petrochemicals — H2S, HF and hydrocarbon leaks on platforms and at flanges
  • Fertilisers and basic chemicals — ammonia, CO2, HCl on the perimeter of the plants
  • Natural gas and upstream oil — methane along pipeline routes and in stations
  • Metallurgy and chemicals — process gases and emissions
  • Carbon capture and storage — CO2 monitoring on the perimeter

How do we supply Boreal Laser in Romania?

We quote GasFinder3 analysers, measuring heads and Shur-Shot detectors, as well as parts for installed systems. They are supplied to order, usually within 1–4 weeks; analysers configured with several channels, special heads and cable lengths may need more time. The request should contain the gases to be measured and their ranges, the type of application (perimeter, stack, pipe, extracted sample), the length of the path and of the cables, the zone classification, the power supply and the number of analogue outputs or relays. An item can ship in 24–72 h when the item is in stock, locally or at the supplier; the final lead time appears in the quotation.

The suitability of open path detection for a given site is established after analysing the path and the background gases.

Frequently asked questions about Boreal Laser

What does Boreal Laser make?

TDLAS-based laser gas analysers and detectors: the GasFinder3 series with interchangeable measuring heads, the Shur-Shot HF detector and transportable systems. The company was founded in 1990 in Edmonton, Canada.

How do I choose the measuring head for GasFinder3?

It depends on where you need to measure the gas. OPX for leaks along a free path, RPX for a point measurement with fast response, SDX for a stack, EMX for an extracted sample, IPX and ILX for a pipe. The mounting location and the nature of the gas decide.

Can you supply Boreal Laser equipment in Romania, and how long does it take?

Yes. A GasFinder3 or a measuring head is supplied to order, usually within 1–4 weeks. Cables and accessories can ship in 24–72 h when the item is in stock, locally or at the supplier. Analysers configured with several channels and long cable lengths are confirmed separately.

Can I replace a GasFinder2 with a GasFinder3 version?

Compatibility is confirmed after checking. The GasFinder3-MCr rack accepts both GasFinder3 heads, via CAT6/5e, and GasFinder2 heads, via coaxial cable, but the head model, the gas and the cable length have to be confirmed.

What data is needed for a quotation for a laser gas detector?

The gas and the range of interest, the type of measurement (perimeter, stack, pipe), the path length, the zone classification, the available power supply, the number of channels, and the analogue outputs and relays required.

How do I request a Boreal Laser quotation?

Send the Boreal Laser code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote