Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

AP2E supplier in Romania

ProCeas multi-gas laser analysers and LaserCEM emissions systems

Founded in 2006 · Headquarters: Aix-en-Provence, France

Request a quote

Who is AP2E and what does it make?

AP2E is a French company based in Aix-en-Provence, founded in 2006 to bring into industry laser spectroscopy techniques developed in research. It makes gas analysers based on OFCEAS (optical feedback cavity enhanced absorption spectroscopy), combined with low-pressure sampling (LPS). Through this combination, the instruments measure very low gas concentrations without interference between components and with a short response time. The main families are ProCeas, for processes and pure gas analysis, LaserCEM, a continuous emissions monitoring system, and ProCeas NAV, a compact version for air in enclosed spaces.

ProCeas is supplied in versions specialised by the gas measured: H2S in natural gas or in liquefied natural gas, NH3, O2, CO, H2 in chlorine, NOx, SO2, HCl, HF, HCN, N2O, CH4 and H2O, as a biogas or hydrogen analyser. LaserCEM is a ready-calibrated CEMS, with approvals according to the manufacturer's documentation. The measuring ranges include, for example, NO between 0 and 78 mg/Nm³, HF between 0 and 1.5 mg/Nm³ and CO between 0 and 30 mg/Nm³. Several gases can be measured at once: HF, HCl, NH3, SO2, CO, CO2, NO, NO2, O2, H2S, H2O.

Such analysers are considered for incinerators and industrial stacks with strict emission limits, for biogas plants, for chemical units and refineries, for hydrogen processes and for installations with DeNOx. The choice is made according to the gases to be measured, the range and detection limit wanted, the gas matrix and the certification requirements imposed by the environmental permit.

What do we supply from the AP2E range?

ProductDescription
ProCeasMulti-gas laser analyser for processes and pure gas, in dedicated versions: biogas, H2S in natural gas, NH3, O2, CO, H2 in chlorine, NOx, SO2, HCl, HF, H2O, hydrogen. Multi-laser configurations made to order for a process also exist.
LaserCEMTurnkey continuous emissions monitoring system, pre-calibrated and with approvals stated in the manufacturer's technical documentation, with simultaneous analysis of several parameters (HF, HCl, NH3, CH4, SO2, CO, CO2, NO, NO2, O2, N2O, H2S, CH2O, H2O) at stacks.
ProCeas H2SLaser analyser for traces of H2S in natural gas, syngas and biogas. Versions dedicated to liquefied natural gas also exist, where H2S and moisture are measured.
ProCeas BiogasVersion for complete monitoring of the methanisation process, with multi-gas measurement in a single instrument, for biogas plants that track the quality of the gas produced.

Why AP2E?

  • OFCEAS laser spectroscopy with low-pressure sampling: measurement without interference, at very low concentrations
  • LaserCEM with approvals according to the manufacturer's documentation: usable for regulated emissions monitoring
  • Fine certified ranges, such as NO 0–78 mg/Nm³ and HF 0–1.5 mg/Nm³: suitable for strict emission limits
  • ProCeas range by gas measured: H2S, NH3, O2, CO, H2, NOx, SO2, HCl, HF, HCN, N2O, CH4, H2O
  • Configurable multi-laser version: ProCeas to order, for gas combinations needed by a specific process

Which AP2E codes and series are requested most often?

CodeDescription
ProCeasMulti-gas laser analyser, OFCEAS with low-pressure sampling
ProCeas BiogasAnalyser for complete monitoring of methanisation
ProCeas H2SH2S in natural gas, syngas and biogas
ProCeas H2S LNGH2S in liquefied natural gas
ProCeas H2O LNGMoisture in liquefied natural gas
ProCeas NH3NH3 in pure gas
ProCeas NH3 DeNOxNH3 in DeNOx processes
ProCeas COLow-level CO, for safety
ProCeas O2Low-level O2, for combustion processes
ProCeas H2 TraceH2 in a chlorine or other gas matrix
ProCeas H2 purityCH4, H2S, CO and CO2 in H2 streams
ProCeas NOx TraceNO + NO2 in combustion processes
ProCeas SO2 TraceLow-level SO2 in wet stack gases
ProCeas CustomMulti-laser configuration to order
LaserCEMMulti-gas CEMS with measurement approvals stated in the manufacturer's documentation
ProCeas NAVCompact analyser for air in enclosed spaces

Where is AP2E equipment used?

  • Incinerators and co-incineration: continuous monitoring of HCl, HF, NH3, CO and NOx at the stack
  • Biogas: tracking methanisation and the gas produced (CH4, H2S, NH3)
  • Chemicals and hydrogen: H2 in chlorine, H2 purity, traces of H2O
  • Refineries and gases: H2S and H2O in natural gas and in liquefied natural gas
  • Installations with DeNOx: residual NH3 and NOx at the system outlet

How do we supply AP2E in Romania?

We can prepare quotations for AP2E ProCeas and LaserCEM analysers. Equipment is supplied to order; the systems are configured per application, so the lead time can be longer than for standard instruments, and usually starts from 1–4 weeks. For a correct quotation we need the gases to be measured, the range and detection limit wanted, the temperature, pressure and humidity of the gas, the type of application (process or regulated emissions) and whether QAL 1 certification is needed. We confirm the configuration and exact lead time in the quotation, after we analyse the data received.

Maintenance and recalibration of AP2E analysers follow the manufacturer's documentation; the conditions are clarified with each order.

Frequently asked questions about AP2E

What product range does AP2E have?

AP2E, from Aix-en-Provence, makes laser gas analysers based on OFCEAS spectroscopy and low-pressure sampling: the ProCeas family for processes and pure gas, the LaserCEM system for continuous emissions monitoring and ProCeas NAV for air in enclosed spaces.

How do I choose between a process ProCeas and a LaserCEM for a stack?

ProCeas is chosen for process or gas quality measurements (biogas, H2S in natural gas, hydrogen). LaserCEM is the system for regulated emissions, with measurement approvals stated in the manufacturer's documentation. Send us the gases and the limits from the permit for a recommendation.

Do you supply AP2E analysers in Romania, and how quickly?

Yes, to order. As these are systems configured per application, the lead time to order is usually 1–4 weeks and can be longer, depending on the gases measured and the certifications required; it is confirmed in the quotation.

Can I replace an existing stack analyser with a LaserCEM?

Possibly, but replacing a CEMS requires compatibility with the probe, the sampling line, the acquisition system and the requirements of the environmental permit. We confirm equivalence after checking; send us the make and model of the current analyser, the list of parameters and the measuring ranges from the nameplate.

What information do you need for an AP2E analyser quotation?

State the gases to be measured and the ranges, the emission limits or the process specification, the temperature, pressure, humidity and dust in the gas, the place of installation and whether QAL 1 certification is required. For biogas, also give the type of plant and the probable gas composition.

How do I request a AP2E quotation?

Send the AP2E code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: AP2E (manufacturer documentation)