ATOM Instrument supplier in Romania
Total sulphur and total nitrogen analysers, process and laboratory
Founded in 1962 · Headquarters: Houston, USA
Who is ATOM Instrument and what does it make?
ATOM Instrument is an American line of elemental analysers for total sulphur and total nitrogen, in liquids, solids and gases, made in Houston, Texas. The brand has existed since 1962. All the analysers use excimer ultraviolet fluorescence (EUVF), a patented technology that limits nitrogen interference when sulphur is measured at low concentrations.
Sulphur in fuels and process gas poisons catalysts, corrodes equipment and, on burning, reaches the atmosphere as SO2. For this reason refineries, gas treatment plants and petrochemical installations measure it along the whole chain: feedstock, intermediate products and finished product. The 1000 series is intended for online monitoring: Trace-1000 S/N for traces of sulphur or nitrogen, SGA-1000 for total sulphur in gases on several streams, SLA-1000 for liquids. The XT-2000 is the laboratory version, with a wide dynamic range and ASTM methods D5453, D6667 and D4629.
The interest is practical: refinery laboratories, installations that must prove low sulphur content in gas or fuel and operators of natural gas and liquefied petroleum gas. An online analyser can be mounted outdoors, without a shelter, with bottled compressed air as the main utility. The ASTM methods mentioned cover total sulphur in light hydrocarbons and fuels (D5453), volatile sulphur in gases and LPG (D6667) and trace nitrogen in liquid hydrocarbons (D4629).
What do we supply from the ATOM Instrument range?
| Product | Description |
|---|---|
| Trace-1000 S/N | Online analyser for traces of sulphur (S-1000) or nitrogen (N-1000) in refinery gases, with detection limits below 1 ppm, a single calibration, designed for outdoors without an analyser shelter. |
| SGA-1000 | Multi-stream analyser for total sulphur or total nitrogen in gases. It has a short analysis time, user-defined averaging over several cycles and works with bottled air. |
| SLA-1000 | Online analyser for total sulphur in liquids, suited to the 0–10 ppm range and even below 1 ppm. It needs only bottled air, no other gases, and needs no shelter. |
| XT-2000 | Laboratory analyser for total sulphur and total nitrogen, compact, with a wide dynamic range. It works with air or oxygen-argon mixtures for combustion and complies with ASTM D5453, D6667 and D4629. |
Why ATOM Instrument?
- Patented EUVF technology — high sulphur sensitivity with minimal nitrogen interference, so stable results at levels below 1 ppm
- Trace-1000 S/N responds to 99% of the process change in up to 180 seconds — used where the operator adjusts the plant according to the measurement
- SGA-1000 and SLA-1000 work with bottled air — they need no additional carrier or combustion gases and no shelter
- Compliance with ASTM methods D5453, D7183, D7551, D4629 and D6667 — covering fuels, aromatics, gases and LPG
- Laboratory and process from the same family — XT-2000 for laboratory samples, 1000 series for the line, with the same detection technology
Which ATOM Instrument codes and series are requested most often?
| Code | Description |
|---|---|
| Trace-1000 S/N | Online analyser for traces of sulphur or nitrogen in gases |
| S-1000 | Version for traces of sulphur |
| N-1000 | Version for traces of nitrogen |
| SGA-1000 | Multi-stream analyser for total sulphur or nitrogen in gases |
| SLA-1000 | Analyser for total sulphur or nitrogen in liquids |
| XT-2000 | Laboratory analyser for total sulphur and total nitrogen |
Where is ATOM Instrument equipment used?
- Refineries — sulphur in feedstocks, intermediate and finished products
- Natural gas and LPG — total volatile sulphur in gases and liquefied petroleum gases
- Petrochemicals — sulphur and nitrogen in aromatic hydrocarbons and process streams
- Flaring — total sulphur in flare gas for emissions compliance
- Quality control laboratories — sulphur and nitrogen analysis in fuels
How do we supply ATOM Instrument in Romania?
Request a quotation for ATOM Instrument process or laboratory analysers, or for consumables and parts of an instrument already installed. Items are supplied to order, usually in 1–4 weeks; for complex systems, with a conditioned sample, the lead time can increase. For an online analyser we need the sample matrix (gas, liquid or flare stream), the sulphur or nitrogen range expected, the pressure and temperature at sampling, the ASTM method the result must comply with and the classified area. Parts can ship in 24–72 h when the item is in stock, locally or at the supplier, and the precise lead time comes with the quotation.
The detection limit wanted on a particular sample is established from the matrix data and a validation on the sample.
Frequently asked questions about ATOM Instrument
What products does ATOM Instrument make?
Laboratory and process analysers for total sulphur and total nitrogen in liquids, solids and gases, based on excimer UV fluorescence. They are made in Houston and used in refineries, in petrochemicals and in gas transport.
How do I choose between Trace-1000 S/N and SGA-1000?
The Trace-1000 S/N is designed for traces, below 1 ppm, of sulphur or nitrogen in refinery gases. The SGA-1000 is a multi-stream analyser for total sulphur or total nitrogen in gases, with a short analysis time. The difference lies in the concentration range and the number of sampling points.
How long does delivery to Romania take for ATOM Instrument analysers?
We can supply ATOM Instrument analysers to order, usually in 1–4 weeks. Tapes, combustion tubes and other consumables can ship in 24–72 h when the item is in stock, locally or at the supplier. Multi-stream systems with a conditioned sample need extra time.
Can I use a process analyser instead of a laboratory one?
It depends on the method required. The XT-2000 complies with laboratory ASTM methods (D5453, D6667, D4629), while the 1000 series is designed for online, in-line measurement. Results are compared only after checking; tell us the standard you follow and we confirm it.
What information is needed for a quotation for a sulphur analyser?
The type of sample (gas, liquid, flare), the sulphur or nitrogen range, the number of streams, the pressure and temperature of the sample, the utilities available (compressed air), the ATEX zone and the ASTM method followed.
How do I request a ATOM Instrument quotation?
Send the ATOM Instrument code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: Process Insights (manufacturer documentation)