Teledyne Monitor Labs supplier in Romania

ML660, ML661, ML670 and ML675 CEMS systems for stack emissions

Request a quote

Who is Teledyne Monitor Labs and what does it make?

Teledyne Monitor Labs, TML for short, is a company that designs complete continuous emission monitoring systems (CEMS). The difference from a stand-alone analyser is that the product is a pre-engineered system: heated probe, heated sample line, single-compartment cabinet, analysers, controller and sample conditioning package, all connected through a single point for power, instrument air and calibration gases. This way the utilities no longer need to be duplicated at the stack, and commissioning is done on an assembly that has already been tested.

The ML family has four models according to the sample matrix. ML660 is conventional extractive, dry basis, for SO2, NOx, NH3, CO, CO2 and O2, and can be configured for EPA 40 CFR Part 60 and 75 or for international directives. ML675 works by dilution, so it measures on a wet basis, without removing the water from the sample. ML661 is the system for total hydrocarbons and VOC, with a sensor-e type THC analyser and a zirconium oxide sensor for O2, and ML670 is the system for total reduced sulphur (TRS), with SO2 and O2. The controller runs the sampling, daily calibration and back-purge cycles by itself, and a RegPerfect acquisition system can add reporting.

Systems of this type are of interest to thermal power plants, refineries and installations with emissions of VOC or sulphur compounds. The choice depends on the gases to be measured, the humidity of the gas, the reporting standard and the certifications required by the environmental permit.

What do we supply from the Teledyne Monitor Labs range?

ProductDescription
ML660Conventional extractive CEMS, dry basis, for SO2, NOx, NH3, CO, CO2 and O2. Sample extracted through a filtered, heated probe and conditioned in the cabinet; configurable for EPA 40 CFR Part 60 and 75 or for international directives, with an Open Architecture version.
ML675CEMS on the dilution principle, which measures SO2, NOx, CO, CO2 and O2 on a wet basis. Pressurised dilution air creates the suction, and a precise mass flow meter sets the dilution ratio in real time; PLC controller for all cycles.
ML661Extractive CEMS for total hydrocarbons and VOC, with a sensor-e THC analyser and a zirconium oxide O2 sensor, which extracts and conditions the hot, wet gas for dry-basis measurement, for 40 CFR 60/63 compliance and for process control.
ML670Dilution CEMS for total reduced sulphur (TRS), together with SO2 and O2 on a dry basis, with the option of also measuring NOx, CO and CO2. The sample is filtered, dried and diluted with air, then split between two analysis streams.

Why Teledyne Monitor Labs?

  • Pre-engineered system, not a stand-alone analyser — probe, heated line, cabinet, analysers and controller in one assembly
  • A single connection point for utilities — power, instrument air and calibration gases, with no duplication at the stack
  • ML675 with dilution — wet basis measurement, without removing the water from the sample
  • ML670 for total reduced sulphur — TRS with SO2 and O2, for processes with sulphur compounds
  • Automatic daily calibration and back-purge cycles — the probe filter works for months without intervention

Which Teledyne Monitor Labs codes and series are requested most often?

CodeDescription
ML660Conventional extractive CEMS, dry basis
ML660 OAOpen Architecture version of the ML660
ML661Extractive CEMS for THC and VOC
ML670Dilution CEMS for total reduced sulphur
ML670 OAOpen Architecture version of the ML670
ML675Dilution CEMS, wet basis
ML675 OAOpen Architecture version of the ML675
sensor-e THCTHC analyser used in the ML661
RegPerfect DASData acquisition and reporting system

Where is Teledyne Monitor Labs equipment used?

  • Thermal power plants — CEMS for SO2, NOx, CO, CO2 and O2 at the stack
  • Processes with sulphur compounds — total reduced sulphur with ML670
  • Refineries and petrochemicals — VOC and total hydrocarbons with ML661
  • Industry with wet gases — wet basis measurement with ML675, by dilution

How do we supply Teledyne Monitor Labs in Romania?

We can prepare quotations for the CEMS systems of the Teledyne Monitor Labs ML family: ML660, ML661, ML670 and ML675, together with the associated probes and components. We supply the systems to order; as they are assemblies configured for the application, the lead time can be longer than for standard instruments and is confirmed in the quotation, while for components it is, to order, usually 1–4 weeks. For an accurate quotation we need the gases and ranges to be measured, the humidity, temperature and dust in the gas, the reporting standard and the certifications required, the mounting location and the stack–cabinet distance, plus the utilities available (instrument air, calibration gases).

European type certifications for a specific configuration are clarified before any quotation.

Frequently asked questions about Teledyne Monitor Labs

What products does Teledyne Monitor Labs make?

Teledyne Monitor Labs makes pre-engineered CEMS systems for continuous emission monitoring: ML660 (extractive, dry basis), ML675 (dilution, wet basis), ML661 (THC and VOC) and ML670 (total reduced sulphur), with heated probe, heated line, cabinet and controller.

How do I choose between an extractive ML660 CEMS and a dilution ML675?

ML660 extracts and conditions the sample, measuring on a dry basis; ML675 dilutes the sample with air and measures on a wet basis, without removing the water. The choice depends on the humidity and temperature of the gas and on the reporting standard; send us the gases, ranges and humidity.

Can you supply Teledyne Monitor Labs systems in Romania, and within what time?

Yes, to order. CEMS systems are assemblies configured for the application, so the lead time can be longer; for components it is, to order, usually 1–4 weeks. The exact lead time is confirmed in the quotation, once we have clarified the configuration.

Can an ML660 replace an existing CEMS at the stack?

It depends on the existing analysers, the probe position, the utilities available and the permit requirements. Equivalence is confirmed after checking; send us the make and model of the current system, the list of gases measured and the diagram of the sampling point.

What data do you need for a CEMS quotation?

State the gases and ranges to be measured, the temperature, humidity and dust in the gas, the stack diameter, the distance between the probe and the cabinet, the reporting standard, the certifications required and the utilities available at the mounting location. If you need TRS or VOC, say so from the start.

How do I request a Teledyne Monitor Labs quotation?

Send the Teledyne Monitor Labs code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.