TESTA GmbH supplier in Romania
For TESTA we quote iFiD Mobile, Rack, Wall, NMHC and SHED FID analysers, iFiD Line heated sample lines and iFiD Filter pre-filters; for a quotation we need the gas measured, the concentration range and the installation site.
Who is TESTA GmbH and what does it make?
TESTA GmbH is a German maker of flame ionisation detector (FID) analysers for measuring total hydrocarbons in gases, manufactured in Munich. The company has made FID analysers since 1976, and the instruments are assembled by hand, in small series, by qualified staff. An FID analyser burns the sample in a hydrogen flame and measures the ion current generated by organic carbon, from which the total hydrocarbon concentration results; it is the usual instrument for VOC measurements at the stack, at landfills and in emission test chambers.
The iFiD series has several mounting versions. iFiD Mobile is portable, with a 7-inch touchscreen, with the analytical part heated to 190 °C and a pyrolysis function for cleaning the measuring cell. iFiD Rack is a 19-inch, 3U module for cabinets, with a gas path that can be heated to 300 °C and an injector version for continuous operation. iFiD Wall, for outdoor mounting, has a stainless steel IP65 housing with purging. iFiD NMHC measures total hydrocarbons (THC), methane (CH4) and non-methane hydrocarbons (NMHC) in parallel and complies with EN 12619 and EN 13526, while iFiD SHED is recommended for SHED chambers for measuring evaporative emissions, according to VDA 276.
The range is completed by heated sample lines (iFiD Line, with NiCrNi or PT100 sensor), heated iFiD Filter pre-filters, Filter XL and Backwash M1/M2, valves and inlet protection filters. For Romania, the relevant users are emission laboratories, operators of landfills and gas engines, industrial paint shops and combustion installations.
What do we supply from the TESTA GmbH range?
| Product | Description |
|---|---|
| iFiD Mobile | Portable FID analyser for measuring total hydrocarbons in the field and in the laboratory. The analytical part is heated to 190 °C, with a single measuring range, a TCP/IP interface and an internal list of response factors for real-time correction. |
| iFiD Rack and iFiD Wall | Stationary FID analysers. Rack is a 19-inch, 3U module, with a gas path that can be heated to 300 °C and an injector version for continuous operation; Wall has a stainless steel IP65 housing for outdoor mounting. |
| iFiD NMHC | Stationary FID analyser that measures methane and the sum of hydrocarbons at the same time, calculating NMHC; calibrated in ppmC3 for THC and in CH4 for the methane channel, according to EN 12619 and EN 13526, with EN 24150 in preparation. |
| iFiD SHED, iFiD Line and iFiD Filter | iFiD SHED is a 19-inch rack for SHED chambers, with a bypass and an extractive version, recommended for VDA 276. iFiD Line is the heated sample line, and the iFiD Filter series includes heated pre-filters of 15 and 30 litres. |
Why TESTA GmbH?
- iFiD Mobile for the field — 7-inch touchscreen, analytical part heated to 190 °C and a pyrolysis function for cleaning the measuring cell
- iFiD Rack for continuous operation — 19-inch module with a gas path that can be heated to 300 °C and an injector version for non-stop operation
- iFiD Wall in a stainless steel IP65 housing — outdoor installation all year round, with housing purging
- iFiD NMHC measures THC, CH4 and NMHC simultaneously — useful at landfills, gas engines, biofilters and burner test stands
- Heated pre-filters with backwash (Backwash M1/M2) — fewer stops for cleaning the sample line
Which TESTA GmbH codes and series are requested most often?
| Code | Description |
|---|---|
| iFiD Mobile | Portable FID, analytical part heated to 190 °C |
| iFiD Rack | Stationary 19-inch, 3U FID, gas path heated up to 300 °C |
| iFiD Wall | Stationary FID in a stainless steel IP65 housing |
| iFiD NMHC Rack | FID for THC, CH4 and NMHC in parallel |
| iFiD NMHC Mobile | Portable version of the NMHC analyser |
| iFiD SHED | 19-inch FID for SHED chambers, VDA 276 |
| iFiD Line | Heated sample line, NiCrNi or PT100 sensor |
| iFiD Filter | Heated pre-filter, 15 litres |
| iFiD Filter XL | Heated pre-filter, 30 litres |
| iFiD Filter Backwash M1 | Heated pre-filter with backwash |
| iFiD Filter Backwash M2 | Heated pre-filter with backwash, second version |
| Magnetic valve 1012 | Heated solenoid valve with two channels for two sample lines |
Where is TESTA GmbH equipment used?
- Emission measurement laboratories — total hydrocarbons in waste gases
- Landfills and gas engines — THC, CH4 and NMHC
- Automotive industry — SHED chambers and burner test stands
- Fuel cells and optimisation of combustion processes
- Biofilters and installations for treating air loaded with VOC
How do we supply TESTA GmbH in Romania?
We can quote the FID analysers of the iFiD series (Mobile, Rack, Wall, NMHC, SHED), the heated sample lines and the pre-filters in the range. They are supplied to order, usually in 1–4 weeks; where the instrument is configured for the application, the lead time may be longer, and we set the date in the quotation. For an accurate request, useful to us are the gas measured and the concentration range, the sample temperature, the installation conditions (field, cabinet, outdoors), the length of the sample line and the standard the measurement must meet.
Whether a model meets a standard or an approval required by the environmental authority is checked on the basis of the application described.
Frequently asked questions about TESTA GmbH
What does TESTA GmbH make?
TESTA makes FID analysers (with a flame ionisation detector) for total hydrocarbons in Munich, in portable, rack, outdoor-mounted, NMHC and SHED chamber versions, plus heated sample lines, pre-filters, valves and protection filters.
How do I choose between iFiD Mobile, Rack and Wall?
Mobile is for field measurements, with frequent changes of location; Rack is mounted in a cabinet, for continuous analysis in a laboratory or cabin; Wall is for outdoor installation, in a stainless steel IP65 housing. Tell us the installation site and the operating regime.
Do you supply TESTA analysers in Romania and within what lead time?
Yes, TESTA analysers are supplied to order. For instruments configured for the application, the lead time may be longer, and the exact date is confirmed in the quotation, together with the list of accessories.
Can I replace a heated pre-filter or a sample line?
Yes, iFiD Filter, Filter XL and Backwash M1/M2 are replaced as separate modules, and iFiD Line is ordered to the length required. Send us the analyser type, the line length, the working temperature and the sensor wanted (NiCrNi or PT100).
What data should I send for a quotation on an FID?
State the gas measured and the concentration range, whether the sample contains dust or condensable vapours, the sample temperature, the applicable standard and the installation site. For NMHC, state whether you need methane and THC in the same instrument.
How do I request a TESTA GmbH quotation?
Send the TESTA GmbH code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: TESTA GmbH (manufacturer documentation)