Teledyne Advanced Pollution Instrumentation supplier in Romania

For Teledyne API we quote T100, T200, T300, T400 and T500U analysers and T700 calibrators; we need the gas to be measured, the range, the sample conditions and the model of the instruments in the existing station.

Request a quote

Who is Teledyne Advanced Pollution Instrumentation and what does it make?

Teledyne Advanced Pollution Instrumentation, also known as Teledyne API or TAPI, makes gas analysers for monitoring ambient air and emissions, plus dynamic calibrators for these analysers. For an environmental laboratory or for the operator of a combustion plant, the challenge is continuous measurement, at very low concentrations, of regulated gases, with an instrument that does not drift between two calibrations. The T series has a colour touchscreen display, flexible inputs and outputs, data logging and communication over RS232, Ethernet or USB, with NumaView software for remote connection.

Each model uses its own measurement principle. T100 measures sulphur dioxide by ultraviolet fluorescence, with an optical shutter to compensate for photomultiplier tube drift and an element that removes hydrocarbon interference. T200 measures NO, NO₂ and NOx by chemiluminescence, with an AutoZero function and adaptive filtering, for ambient air or for dilution CEMS systems (continuous emission monitoring). T300 measures carbon monoxide in the infrared with gas filter correlation, on a folded optical path of 14 m, and T400 measures ozone by absorption at 254 nm. T500U measures nitrogen dioxide directly with the CAPS technique (cavity attenuated phase shift), without catalytic conversion. T700 is a calibrator with mass flow controllers and up to four gas sources, with an ozone generator and a gas phase titration chamber as options.

There are also T201 for ammonia, T360 for carbon dioxide, T640 for suspended particulate mass, instruments for ozone dissolved in water, up to 150 mg/l, and for methane and total hydrocarbons. The offer starts from the analyser model, where an existing station is being completed, or from the gas to be measured, the range and the mounting conditions, for a new station.

What do we supply from the Teledyne Advanced Pollution Instrumentation range?

ProductDescription
T100 (SO₂) and T200 (NO/NO₂/NOx)T100 uses ultraviolet fluorescence, with an optical shutter and a reference for the UV lamp. T200 uses chemiluminescence, with a permeation inlet dryer for the ozone generator, AutoZero and adaptive filtering, for ambient air or dilution CEMS.
T300 (CO) and T400 (O₃)T300 measures carbon monoxide in low ranges, by gas filter correlation and a folded optical path of 14 m. T400 measures ozone in air by absorption at 254 nm, periodically alternating the sample with a sample from which the ozone has been removed.
T500U (direct NO₂)Analyser that measures nitrogen dioxide directly with the CAPS technique, without catalytic conversion and without reagents. It reduces maintenance parts and does not need high-temperature scrubbers; the expected maintenance interval is one year in usual ambient monitoring.
T700 (dynamic calibrator) and additional instrumentsT700 uses precise mass flow controllers and reference gas sources for zero and multipoint calibrations, with up to four sources and an optional ozone generator. T703 is an ozone calibrator, and the programme also includes T201 for ammonia, T360 for CO₂ and T640 for suspended particulate matter.

Why Teledyne Advanced Pollution Instrumentation?

  • Dedicated measurement principles — UV fluorescence for SO₂, chemiluminescence for NOx, correlation infrared for CO and UV absorption for ozone
  • Zero correction — T200 has AutoZero and adaptive filtering, so zero drift is corrected continuously between calibrations
  • Direct NO₂ — T500U measures nitrogen dioxide with the CAPS technique, without a catalytic converter and without reagents
  • Calibration in the same family — T700 has mass flow controllers, up to four gas sources and, optionally, an ozone generator and photometer
  • Remote control and access — colour touchscreen, RS232, Ethernet, USB and NumaView software for data download

Which Teledyne Advanced Pollution Instrumentation codes and series are requested most often?

CodeDescription
T100SO₂ analyser by ultraviolet fluorescence
T200NO/NO₂/NOx analyser by chemiluminescence
T300CO analyser by gas filter correlation
T400Ozone analyser by UV absorption
T500UDirect NO₂ analyser, CAPS technique
T700Dynamic calibrator with mass flow controllers
T200UNO/NO₂/NOx analyser for very low concentrations
T201Ammonia analyser with external thermal converter
T300UCO analyser for very low concentrations
T360CO₂ analyser by gas filter correlation
T640PM particulate mass monitor by scattered light spectrometry
T703Ozone calibrator, 50 ppb to 5 ppm

Where is Teledyne Advanced Pollution Instrumentation equipment used?

  • Air quality monitoring — ambient air stations with NOx, SO₂, CO and ozone
  • Emission monitoring — analysers for dilution CEMS systems
  • Environmental laboratories — calibration with gas standards and gas phase titration
  • Combustion plants — flue gas samples conditioned ahead of the analyser
  • Water treatment — measurement of ozone dissolved in water

How do we supply Teledyne Advanced Pollution Instrumentation in Romania?

We can quote Teledyne API analysers in the T series, from T100, T200, T300 and T400 to T500U, T201, T360 and T640, as well as T700 and T703 calibrators, with accessories for them. They are supplied to order, usually 1–4 weeks; depending on the specification, the lead time can be longer for complete stations with several analysers. For an accurate quotation, send us the gas to be measured, the range, the sample conditions (ambient air or flue gas), the number of analysers, the outputs required and, when completing a station, the model and serial number of the existing instruments.

The model for a flue gas sample is chosen on the basis of composition, temperature and moisture content.

Frequently asked questions about Teledyne Advanced Pollution Instrumentation

What does Teledyne API make?

Teledyne API makes T series gas analysers for ambient air and emissions, with dedicated principles for SO₂, NOx, CO, ozone and NO₂, plus T700 dynamic calibrators. The series has a colour touchscreen, data logging and RS232, Ethernet or USB communication.

How do I choose the model for nitrogen oxides?

T200 measures NO, NO₂ and NOx by chemiluminescence, while T500U measures NO₂ directly with the CAPS technique, without catalytic conversion. The choice depends on the gases required by the programme and the maintenance interval desired. Send us the gases, the range and the sample conditions.

Can Teledyne API analysers be supplied in Romania and how fast?

Analysers are supplied to order, usually in 1–4 weeks. An accessory can ship in 24–72 h when the item is in stock, locally or at the supplier, and stations with several analysers, depending on the specification, can take longer; the exact lead time appears in the quotation.

Can an older T analyser be replaced with a current model?

It can be checked on the basis of the model and serial number, and interchangeability is checked on the data, not by the name. Range, outputs, software and pneumatic connections all matter; send us the data from the plate and a photo of the installation in the station.

What data do I need to send for a quotation on a gas analyser?

Send the gas or gases to be measured, the range, the sample type (ambient air, diluted gas or flue gas), its temperature and humidity, the outputs required, the number of analysers and whether you need a calibrator. For an existing station, add the models installed.

How do I request a Teledyne Advanced Pollution Instrumentation quotation?

Send the Teledyne Advanced Pollution Instrumentation code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote