Teledyne Analytical Instruments supplier in Romania
For Teledyne Analytical Instruments we quote the 3000TA and 3020T trace oxygen analyzers, the 3000MB and 3010MA paramagnetic analyzers, the 3300 series and the 3110 portable analyzer, based on the balance gas and the measuring range.
Headquarters: City of Industry, California, USA
Who is Teledyne Analytical Instruments and what does it make?
Teledyne Analytical Instruments is an American manufacturer based in City of Industry, California, that makes gas and liquid analyzers, sensors and integrated analysis systems, including solutions for areas with an explosion hazard, in ATEX versions according to the manufacturer's documentation. The offer includes oxygen analyzers, from ppm (parts per million) traces to percent oxygen, used for process control with industrial gases.
The range is divided by sensor principle. The Micro-fuel Cell electrochemical cell, sealed and with no electrolyte to replace, equips the 3000TA trace analyzer, the explosion-proof 3020T (NEMA 4/7 enclosure, ranges from 0–10 ppm up to 0–250,000 ppm), the intrinsically safe 3010TC and 3010PC series and the 3110 portable analyzer. The paramagnetic sensor is in the percent analyzers 3000MB (three ranges, from 0–5% up to 0–100%) and 3010MA (narrow ranges between 95 and 100%, with barometric compensation and a heated compartment). The 3300 series can be ordered with an electrochemical cell, with zirconium oxide or with a paramagnetic sensor, and the 3190 and 3290 are compact versions for ppm and percent ranges respectively.
Such analyzers are used in air separation plants, in gas pipelines and stations, in petrochemicals, where they protect hydrocarbon streams with an inert atmosphere, in semiconductor production and in soldering or heat treatment furnaces. The choice depends on the balance gas, the oxygen range, the installation zone and the required outputs, which is why the quotation starts from the existing model or from the application sheet.
What do we supply from the Teledyne Analytical Instruments range?
| Product | Description |
|---|---|
| 3000TA and 3020T | Trace oxygen analyzers with a Micro-fuel Cell, three configurable ranges (minimum 0–10 ppm) and 0–1 V and 4–20 mA outputs; the 3020T is the explosion-proof version, in a NEMA 4/7 enclosure, with ranges up to 0–250,000 ppm. |
| 3000MB and 3010MA | Paramagnetic percent oxygen analyzers: 3000MB for ranges from 0–5% to 0–100% in air separation and petrochemicals, 3010MA for purity analysis, with ranges between 95 and 100%, 19-inch rack mounting. |
| 3300 series and models 3190 and 3290 | Compact process analyzers for trace and percent oxygen, with an electrochemical, zirconium oxide or paramagnetic sensor, automatic range selection, alarms and rack or wall enclosure mounting; 3190 in ppm, 3290 in percent. |
| 3010TC, 3010PC and 3110 | Intrinsically safe analyzers: the 3010TC and 3010PC have a control unit separate from the probe in the hazardous area, and the 3110 is portable, with batteries for at least 100 hours of continuous operation and versions for areas with an explosion risk, according to the manufacturer's documentation. |
Why Teledyne Analytical Instruments?
- Sealed electrochemical sensor — the Insta Trace Micro-fuel Cell in the 3000TA needs no electrolyte replacement and works in streams of up to 100% hydrocarbons
- Calibration on ambient air — the linear cell from 0 ppm to 100% oxygen allows calibration on air, without span gas, on the 3000TA analyzer
- Versions for hazardous areas — 3020T in an explosion-proof NEMA 4/7 enclosure, 3010TC and 3010PC intrinsically safe with a remote analysis unit, portable 3110
- Three sensor technologies in the 3300 series — electrochemical, zirconium oxide and paramagnetic, in rack or wall mounting
- Paramagnetism with barometric compensation — the 3010MA keeps the sensor in a heated compartment with PID control for oxygen purity analysis
Which Teledyne Analytical Instruments codes and series are requested most often?
| Code | Description |
|---|---|
| 3000TA | Trace oxygen analyzer, Micro-fuel Cell |
| 3020T | Trace oxygen analyzer, NEMA 4/7 explosion-proof enclosure |
| 3000MB | Paramagnetic percent oxygen analyzer |
| 3010MA | Paramagnetic analyzer for oxygen purity |
| 3010TC | Trace oxygen analyzer, intrinsically safe |
| 3010PC | Percent oxygen analyzer, intrinsically safe |
| 3110 | Portable oxygen analyzer, trace and percent |
| 3190 | Compact trace oxygen analyzer, 0–10 and 0–1000 ppm |
| 3290 | Compact percent oxygen analyzer, 1–25% |
| 3300T | 3300 series, electrochemical cell, trace |
| 3300Z | 3300 series, zirconium oxide sensor |
| 3300M | 3300 series, paramagnetic sensor |
Where is Teledyne Analytical Instruments equipment used?
- Industrial gases — air separation and liquefaction, gas purity certification
- Petrochemicals — inert atmosphere for hydrocarbon streams and monomer monitoring
- Natural gas — oxygen in pipelines and in treatment and transmission stations
- Semiconductors and electronics — soldering furnaces and controlled atmospheres
- Heat treatment and welding — protective atmospheres and inert gases
How do we supply Teledyne Analytical Instruments in Romania?
We can quote Teledyne Analytical Instruments oxygen analyzers for traces and for percent, in panel, wall, explosion-proof, intrinsically safe or portable versions. We supply them to order, usually in 1–4 weeks; depending on the specification, the lead time can be longer for systems with sampling. For a quotation send us the model from the nameplate, the balance gas and any hydrocarbons or acid gases in the sample, the oxygen range, the installation zone (with or without explosion hazard), the required outputs and whether you need a sampling system. The exact lead time is confirmed in the quotation.
The right sensor depends on the balance gas and the oxygen range, and the presence of acid gases in the sample must be declared before the quotation.
Frequently asked questions about Teledyne Analytical Instruments
What does Teledyne Analytical Instruments make?
The company, based in City of Industry (California), makes gas and liquid analyzers, sensors and custom analysis systems, including for hazardous areas. The oxygen analyzers are offered, for traces and for percent, with electrochemical, paramagnetic or zirconium oxide sensors.
How do I choose between an electrochemical, paramagnetic and zirconium oxide sensor?
The Micro-fuel Cell electrochemical cell suits traces and hydrocarbons, the paramagnetic sensor suits percent levels in clean gases, including in corrosive applications or at high temperature, and zirconium oxide suits clean, non-corrosive streams. Send us the balance gas, the sample temperature and the oxygen range, and we recommend the model.
Do you supply Teledyne oxygen analyzers in Romania and how fast?
Yes; Teledyne Analytical Instruments items are supplied to order. Depending on the specification, the lead time can be longer, for example for explosion-proof models or those with a sampling system. The exact lead time is confirmed in the quotation.
What do you check if I want to replace an older 3000TA analyzer?
We check the model and serial number from the nameplate, the measuring ranges, the outputs used (0–1 V or 4–20 mA), the panel mounting type and the sampling system. The equivalence is confirmed after we compare these data; a photo of the installation helps.
What data do I send for a quotation on a 3110 portable analyzer?
Send the gas measured (for example natural gas or nitrogen), the oxygen range in ppm or percent, the approval required for the work area (ATEX or FM) and whether you need an external sampling system. The 3110 runs on batteries for at least 100 hours.
How do I request a Teledyne Analytical Instruments quotation?
Send the Teledyne Analytical Instruments code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Teledyne Analytical Instruments (manufacturer documentation)