Tecnar supplier in Romania
For Tecnar we quote Galvalibs 2.0 LIBS analysers for zinc baths and Alulibs for molten aluminium, with positioning devices and a control unit; for a quotation we need the bath type, the elements to be monitored and the installation space.
Headquarters: Saint-Bruno, Québec, Canada
Who is Tecnar and what does it make?
Tecnar is a Canadian manufacturer based in Saint-Bruno, in Québec, which builds LIBS (laser-induced breakdown spectroscopy) analysers for molten metal, mounted directly on the production line. The principle is simple: a laser pulse, sent through a ceramic lance immersed in the bath, heats a small volume of metal to the plasma state, and the emitted light is analysed by a spectrometer; the spectral lines of each element give the concentration. Because the liquid metal is measured, the concentrations of the dissolved elements are read directly, without a temperature-based calculation model.
The range has two lines. Galvalibs 2.0 is the analyser for zinc baths on hot-dip galvanising lines: it monitors effective aluminium, dissolved iron, magnesium, silicon and antimony and can monitor the bath level and the dross level. It can switch, at the push of a button, between processes such as galvanised (GI), galvanneal (GA), Galvalume (GL), Galfan (GF), aluminised (AlSi) and Zn-Al-Mg (ZAM). Alulibs is the variant for molten aluminium, with predefined calibration curves for the specified element ranges and with a web interface, accessible from any computer.
The equipment consists of a probe with DuraBeam sealed optics, a ceramic lance inert to molten zinc and aluminium, a motorised or manual positioning device (positioning accuracy under 1 mm, with safety interlocks), a control unit with a PLC, in an IP 54 enclosure, which can stand up to 40 m from the bath, and a high-purity gas system. The equipment is of interest to sheet galvanising and aluminising lines and to foundries that want to replace part of the manual sampling with continuous measurement.
What do we supply from the Tecnar range?
| Product | Description |
|---|---|
| Galvalibs 2.0 | LIBS analyser for zinc baths on hot-dip galvanising lines, which measures effective aluminium, dissolved iron, magnesium, silicon and antimony and monitors the bath level and the dross level. It is installed in a probe with sealed optics, introduced into the bath through a ceramic lance. |
| Alulibs | LIBS analyser for molten aluminium, used for long-term monitoring of the alloy composition and for transitions between alloys. It comes with predefined calibration curves, so full adjustment is done with a single check sample, and with a web interface. |
| Probe positioning devices | A motorised variant, with an automatic sequence for introduction into the bath (drying the lance, removing dross from the surface), or a manual variant. Both have three positions (in the bath, at rest above the bath, for maintenance), interlocks and accuracy under 1 mm. |
| Control unit and gas system | Control unit with a PLC, passive cooling and an IP 54 enclosure, installable up to 40 m from the analyser, plus a high-purity gas line with a two-stage regulator, a flexible stainless steel hose and dual inlets for changing cylinders without interruption. |
Why Tecnar?
- Direct measurement in molten metal — the concentrations of the dissolved elements are read without temperature corrections or phase models, so data that can be used directly for composition correction
- Galvalibs 2.0 compatible with GI, GA, GL, GF, AlSi, ZAM and 55 % AlZn — a single analyser covers lines with frequent product changes
- Combined monitoring for zinc — composition, bath level and dross level, from the same instrument
- Inert ceramic lance and DuraBeam sealed optics — no single-use probes and a reusable lance
- IP 54 control unit, installable up to 40 m from the bath, with PLC automation — mounting away from the hot area
Which Tecnar codes and series are requested most often?
| Code | Description |
|---|---|
| Galvalibs 2.0 | LIBS analyser for molten zinc in galvanising |
| Alulibs | LIBS analyser for molten aluminium |
| DuraBeam probe | Measuring head with sealed optics and air cooling |
| Ceramic lance | Ceramic cylinder inert to molten zinc and aluminium |
| Motorised positioning device | Motorised positioning, three positions, accuracy under 1 mm |
| Manual positioning device | Manual positioning, three positions, interlocks |
| IP 54 control unit | PLC control, up to 40 m from the analyser |
| Gas system | Two-stage regulator, stainless steel hose, dual inlets |
| Exit window | Replaceable sacrificial part of the probe |
| Bath level monitoring | Galvalibs 2.0 function for the zinc bath level |
| Dross monitoring | Galvalibs 2.0 function for the dross level |
Where is Tecnar equipment used?
- Hot-dip galvanising — control of the composition of zinc, Zn-Al-Mg and aluminising baths
- Aluminium production — monitoring of the alloy composition in the foundry, before casting
- Sheet rolling and coating — reducing manual sampling on lines with continuous production
- Non-ferrous metal foundries — continuous checking of the alloying elements
- Process laboratories — comparison between online measurements and laboratory samples
How do we supply Tecnar in Romania?
We can quote Tecnar Galvalibs 2.0 analysers for zinc baths and Alulibs for molten aluminium, with the positioning devices, the control unit and the gas system. Tecnar is supplied to order; usually 1–4 weeks, and depending on the specification, the lead time may be longer, which is confirmed in the quotation. For a correct request we need the bath type (zinc, Zn-Al-Mg, aluminium), the elements to be monitored, the bath temperature, the installation space above it and the distance to the control room.
Whether an unusual alloy or element can be measured on an existing installation is established after an analysis of the bath and of the concentration range, not remotely.
Frequently asked questions about Tecnar
What does Tecnar make?
Tecnar makes in Canada LIBS analysers for molten metal, mounted on the line: Galvalibs 2.0 for zinc baths in galvanising and Alulibs for molten aluminium. The equipment includes the probe with sealed optics, the ceramic lance, the positioning device and the control unit.
What elements does Galvalibs 2.0 measure in a zinc bath?
Galvalibs 2.0 monitors effective aluminium, dissolved iron, magnesium, silicon and antimony and can also monitor the bath level or the dross level. It can switch between GI, GA, GL, GF, AlSi, ZAM and 55 % AlZn. Send us the product types you make.
Can you bring Tecnar analysers to Romania and how long does it take?
Yes, Tecnar is supplied to order, usually in 1–4 weeks. Since these are configured systems, depending on the specification, the lead time may be longer; the date is confirmed in the quotation, after the positioning and the control unit are determined.
What lance and what positioning device are used?
The lance is a hollow ceramic cylinder, inert to molten zinc and aluminium, with a twist-lock attachment for quick replacement. Positioning can be motorised, with an automatic introduction sequence, or manual. Tell us how much space you have above the bath and what strokes are needed.
What data do I need to send for a quotation on Alulibs?
Send the alloys cast (for example the 6000 series), the elements to be monitored and their concentration ranges, the type of furnace or launder, the metal temperature and the distance between the measuring point and the control room, so that we can determine the configuration.
How do I request a Tecnar quotation?
Send the Tecnar code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Tecnar (manufacturer documentation)