Who is Nanyang Explosion Protection and what does it make?

Nanyang Explosion Protection is a Chinese manufacturer of explosion-proof motors founded in 1970, based in Nanyang, Henan province. The portfolio includes explosion-proof motors, motors for safe areas, generators, explosion-proof fans and electrical apparatus for explosive atmospheres, used in oil, mining, chemicals, metallurgy and power.

The series presented in detail is WEX3, a three-phase asynchronous motor with a flameproof enclosure and IE3 efficiency, developed by European and Asian technical teams. The standard range has frame sizes between 80 and 355, powers from 0.37 to 375 kW, 2, 4, 6 or 8 poles (optionally 10–16 poles), rated voltage of 400 V at 50 Hz and S1 duty (S2–S10 optional). The markings are Ex db eb IIB/IIC T4 Gb, Ex db IIB/IIC T4 Gb, Ex tb IIIC T130 °C Db and Ex tc IIIB T130 °C Dc. The motor is prepared for frequency converter operation up to 500 V in the standard version (according to IEC 60034-25), while at 690 V reinforced insulation is required, the terminal box rotates in 90° steps and the foot can be universal or fixed.

The approvals for explosion-risk zones are those indicated in the manufacturer's documentation. For Romania, the range is of interest to refineries, fuel depots, gas facilities and the chemical industry, for replacing motors for pumps, fans and compressors in areas with explosive atmospheres.

What do we supply from the Nanyang Explosion Protection range?

ProductDescription
WEX3 — IE3 flameproof motorsThree-phase asynchronous motors, frames 80–355, 0.37–375 kW, 2–8 poles standard, 400 V at 50 Hz, with Ex db and Ex db eb markings for gas, and Ex tb or Ex tc for dust.
Motors for safe areasIndustrial motors without explosion protection, made in the same factory, for installations where there is no explosive atmosphere.
Explosion-proof generators and fansElectric generators and fans of explosion-proof construction, for mining, petrochemicals and processes with flammable gases.
Explosion-proof electrical apparatusElectrical instruments intended for explosive atmospheres, complementing the motor range for complete installations.

Why Nanyang Explosion Protection?

  • IE3 efficiency in flameproof motors — the WEX3 series covers frames from 80 to 355 and powers from 0.37 to 375 kW
  • Markings for gas and dust — Ex db, Ex db eb, Ex tb and Ex tc, in the same motor family
  • Converter-ready — variable frequency operation up to 500 V in the standard version and up to 690 V with reinforced insulation
  • Design variants — universal or fixed foot, terminal box rotating in 90° steps, heater and auxiliary boxes
  • Approvals for explosion-risk zones, according to the manufacturer's documentation

Which Nanyang Explosion Protection codes and series are requested most often?

CodeDescription
WEX3 80IE3 flameproof motor, frame 80
WEX3 160M1-2IE3 flameproof motor, frame 160, 2 poles
WEX3 355IE3 flameproof motor, frame 355
Ex db IIB/IIC T4 GbFlameproof marking, gas
Ex db eb IIB/IIC T4 GbFlameproof, increased safety terminal box
Ex tb IIIC T130 °C DbMarking for conductive dust, zone 21
Ex tc IIIB T130 °C DcMarking for non-conductive dust, zone 22
IECEx CNEX 19.0007XApprovals for the WEX3 series according to the data sheet
CNEX 19ATEX 0006XVariants for explosion-risk zones, WEX3 series

Where is Nanyang Explosion Protection equipment used?

  • Oil and gas — pumps, compressors and fans in areas with explosive atmosphere
  • Chemical industry — drives for mixers and pumps
  • Mining and coal — fans and conveyors
  • Metallurgy and power — process pumps and fans
  • Ports and fuel depots — drives for transfer of flammable products

How do we supply Nanyang Explosion Protection in Romania?

We can quote Nanyang explosion-proof motors from the WEX3 series based on the nameplate of the existing motor: size, power, number of poles and Ex marking. Items can ship in 24–72 h when the item is in stock, locally or at the supplier; otherwise they are supplied to order, usually in 1–4 weeks, and motors with special requirements (other voltage, frequency, additional poles) can have a longer lead time. For a correct quotation, send the full code (for example WEX3 160M1-2), the Ex marking required, the voltage, the mounting form and the area of use. The exact lead time is confirmed in the quotation.

Acceptance of a motor for a given classified zone or installation is established on the basis of the manufacturer's complete documentation and the end user's assessment.

Frequently asked questions about Nanyang Explosion Protection

What products does Nanyang Explosion Protection make?

The company makes explosion-proof motors, motors for safe areas, generators, explosion-proof fans and explosion-proof electrical apparatus. The series detailed is WEX3, an IE3 flameproof motor with frames between 80 and 355.

How do I choose the Ex marking of a WEX3 motor?

The marking depends on the classified zone: Ex db or Ex db eb for gases of group IIB/IIC with temperature class T4, Ex tb for conductive dust (zone 21) and Ex tc for non-conductive dust (zone 22). Send us the zone classification and the data of the current motor.

Can you supply Nanyang motors in Romania and in what lead time?

Yes. Items can ship in 24–72 h when the item is in stock, locally or at the supplier; supplied to order, usually 1–4 weeks. Motors with additional poles, another voltage or another frequency can have a longer lead time, stated in the quotation.

Can I replace an existing explosion-proof motor with a WEX3?

Equivalences are confirmed on the basis of the nameplate. We need the nameplate of the current motor: size, power, poles, Ex marking, mounting form and shaft dimensions. Replacement in a classified zone must be validated by the end user, on the basis of the manufacturer's documentation.

What information do you need for a quotation on a flameproof motor?

Send the power, the number of poles, the voltage and frequency, the mounting form (foot or flange), the Ex marking required, whether the drive is with a converter and the environmental conditions. For dust zones, state the zone (21 or 22).

How do I request a Nanyang Explosion Protection quotation?

Send the Nanyang Explosion Protection code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 23 November 2026 · Sources: Wolong Electric Nanyang Explosion Protection Group Co., Ltd., Wolong Holding Group Co., Ltd. (manufacturer documentation)