ORing Industrial Networking supplier in Romania
IEC 61850-3 switches with HSR/PRP, EN 50155, secure routers
Founded in 2005
Who is ORing Industrial Networking and what does it make?
ORing Industrial Networking is a Taiwanese manufacturer of industrial networking and OT security, founded in 2005. The range includes unmanaged and managed Layer 2/3 Ethernet switches, PoE equipment, railway solutions, IEC 61850-3 switches, secure and cellular routers, media converters, serial device servers and wireless access points.
For electrical substations, the IEC 61850-3 range is designed for the electromagnetic and thermal conditions in a digital substation, according to IEC 61850-3 and IEEE 1613. The IEC 61850-3 series are IES-P3073GC, IGS-P9164, IGS-P9812GP, RES-P9242GCL, RGS-P9160GCM1 and the modular RGS-P9000/PR9000 platform. HSR and PRP redundancy according to IEC 62439-3, with zero recovery time, is obtained through the SWM-20GT-HSR module fitted in the RGS-P9000 or RGS-PR9000. An example is RGS-PR92484DGP+, a Layer 3 substation switch with 20 GE ports, 4 combo, 8 1G SFP and 4 1G/2.5G/10G SFP ports, with dual AC/DC power.
Such a switch is mounted in substation communication cabinets and in rolling stock. The series have long names, with suffixes that differentiate the variants; for a quotation or replacement request the whole code is always used, not only the prefix.
What do we supply from the ORing Industrial Networking range?
| Product | Description |
|---|---|
| IEC 61850-3 switches | IES-P3073GC, IGS-P9164, IGS-P9812GP, RES-P9242GCL and RGS-P9160GCM1 series, designed for the electromagnetic and thermal conditions in digital substations, conforming to IEC 61850-3 and IEEE 1613; the series are distinguished by the number and type of ports. |
| RGS-P9000 / RGS-PR9000 modular platform | Modular substation switches; the SWM-20GT-HSR module adds HSR and PRP redundancy with recovery without packet loss. RGS-PR92484DGP+ is a Layer 3 switch with dual AC/DC power. |
| Railway solutions | Industrial Ethernet switches for railway applications, intended for vehicles and on-board equipment. The series are chosen by the number of ports and the power supply. |
| Routers and OT security | Secure routers, VPN cellular routers and wireless access points for industrial networks, with an emphasis on OT cybersecurity, complemented by media converters and serial device servers, for the access nodes. |
Why ORing Industrial Networking?
- A manufacturer specialising in industrial networking and OT security, active since 2005
- Switches for digital substations, conforming to IEC 61850-3 and IEEE 1613 — designed for the electromagnetic and thermal conditions in substations
- HSR and PRP according to IEC 62439-3 through the SWM-20GT-HSR module — redundancy without packet loss on the RGS-P9000 platform
- RGS-PR92484DGP+ with 20 GE, 8 1G SFP and 4 1G/2.5G/10G ports — a substation node with many uplinks
- Switches, secure routers, cellular routers and access points — a single management family
Which ORing Industrial Networking codes and series are requested most often?
| Code | Description |
|---|---|
| IES-P3073GC | IEC 61850-3 switch, series |
| IGS-P9164 | IEC 61850-3 switch, series |
| IGS-P9812GP | IEC 61850-3 switch, series |
| RES-P9242GCL | IEC 61850-3 switch, series |
| RGS-P9160GCM1 | IEC 61850-3 switch, series |
| RGS-P9000 | Modular substation platform |
| RGS-PR9000 | Modular substation platform with redundancy |
| RGS-PR92484DGP+ | Layer 3 substation switch, 20 GE + 8 SFP 1G + 4 SFP 1G/2.5G/10G |
| SWM-20GT-HSR | HSR/PRP module for RGS-P9000 and RGS-PR9000 |
Where is ORing Industrial Networking equipment used?
- Digital transformer substations — IEC 61850-3 switches with HSR/PRP
- Rolling stock — railway switches
- Power installations — redundant communication networks
- Industrial automation — Layer 2/3 switches and secure routers
How do we supply ORing Industrial Networking in Romania?
For ORing we can quote switches, routers and redundancy modules on the basis of the full series code (for example IGS-P9164 or RGS-P9000 with SWM-20GT-HSR). They are supplied to order, usually in 1–4 weeks; configured modular platforms can need a longer lead time. For an accurate quotation we need the series, the number of copper and SFP ports, the need for HSR/PRP, the AC/DC power supply, the temperature and the standard required: IEC 61850-3 or EN 50155. For a model withdrawn from production, we compare the data before quoting a variant.
HSR/PRP performance in an existing network depends on the topology and on the equipment in it.
Frequently asked questions about ORing Industrial Networking
What does ORing Industrial Networking make?
ORing, a Taiwanese company founded in 2005, makes unmanaged, managed Layer 2/3 and PoE industrial switches, IEC 61850-3 and railway switches, secure and cellular routers, media converters, serial servers and wireless access points.
How do I choose an ORing switch for a substation with HSR/PRP?
For HSR and PRP the SWM-20GT-HSR module is used in the RGS-P9000 or RGS-PR9000 modular platform. The number of ports, the uplink type and the power supply matter. Send us the substation topology and the number of intelligent electronic devices (IED).
How fast do you supply ORing equipment in Romania?
ORing series are supplied to order, usually in 1–4 weeks. Modular platforms with configured redundancy modules can have a longer lead time, set in the quotation.
Can I replace an older ORing switch with one from the current series?
Only after comparing the ports, the power supply, the form factor and the redundancy functions. Equivalents are confirmed after checking. Send the label of the old model, with all suffixes, and a photo of the cabinet in which it is mounted. We then check the data against the current series.
What data do I send for a quotation on an IEC 61850-3 switch?
The series you want or the parameters (number of copper ports, 1G and 10G SFP), the need for HSR/PRP, the AC/DC power supply, the mounting type and the temperature range; for a replacement a photo of the label also helps. With these we identify the suitable series.
How do I request a ORing Industrial Networking quotation?
Send the ORing Industrial Networking code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: ORing Industrial Networking Corp. (manufacturer documentation)