Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Particle Measuring Systems supplier in Romania

Airborne and liquid particle counters for cleanrooms

Headquarters: Niwot, Colorado, USA

Request a quote

Who is Particle Measuring Systems and what does it make?

Particle Measuring Systems, PMS for short, is an American manufacturer with its corporate headquarters in Niwot, Colorado, with more than 50 years in contamination monitoring for cleanrooms. The range covers airborne and liquid particle counters, microbial contamination monitors, compressed gas monitoring, facility monitoring systems and software. PMS instruments are used to demonstrate cleanroom class under ISO 14644 and EU GMP Annex 1, in pharmaceutical or electronics factories.

The airborne particle counters include the Lasair Pro, a portable or remote monitoring counter, the Lasair III 110, with true 0.1 µm detection for ISO class 1 and 2 cleanrooms, with Smart Flow technology, the IsoAir Pro, compact, for isolators, and the Airnet II, for integration into a monitoring system. The Handilaz Mini II is the handheld counter, down to 200 nm, and the NanoAir 10 is the 10 nm condensation counter, for continuous operation. For liquids there are the Ultra DI for deionised water, the HSLIS for in-situ monitoring of water and corrosive liquids and batch sampling systems. For microbiology, the BioCapt is the air impactor, and the FacilityPro and FacilityNet collect and report monitoring data.

For a quotation, the application (air, liquid, microbiological), the minimum particle size and the standards followed matter.

What do we supply from the Particle Measuring Systems range?

ProductDescription
Lasair Pro and Lasair III 110Airborne particle counters for cleanrooms. The Lasair Pro offers real-time data, local and remote control and connection through Ethernet, WiFi, Modbus; the Lasair III 110 detects 0.1 µm and comes in two models.
IsoAir Pro, Airnet II and Handilaz Mini IIThe IsoAir Pro is the compact counter for isolators, the Airnet II is the remote counter compliant with Annex 1, and the Handilaz Mini II is the handheld counter down to 200 nm, for troubleshooting.
NanoAir 10A 10 nm condensation counter, built for continuous monitoring, 24 hours out of 24, in a compact format that can be mounted inside semiconductor process equipment.
Ultra DI, HSLIS and BioCaptCounters for liquids (deionised and ultrapure water, corrosive liquids), plus the BioCapt, a microbial air impactor compliant with Annex 1 and ISO 14698, with a design that reduces false positive results.

Why Particle Measuring Systems?

  • Lasair III 110 with true detection at 0.1 µm — certification of ISO class 1 and 2 cleanrooms, with Smart Flow against undercounting in the manifold
  • Lasair Pro and Airnet II — compliant with EU GMP Annex 1 and ISO 21501-4, for mobile or remote monitoring
  • NanoAir 10 at 10 nm — continuous 24/7 operation, with 12 months without maintenance, in process equipment
  • Counters for liquids, from deionised water to corrosive chemicals — Ultra DI and HSLIS
  • FacilityPro and FacilityNet systems — the facility's monitoring data collected and reported in a single system

Which Particle Measuring Systems codes and series are requested most often?

CodeDescription
Lasair ProAirborne particle counter, mobile or remote
Lasair III 110Airborne particle counter, 0.1 µm detection
IsoAir ProRemote particle counter for isolators
Airnet IIAirborne particle counter for remote monitoring
Handilaz Mini IIHandheld particle counter, down to 200 nm
NanoAir 1010 nm condensation counter
Ultra DIParticle counter for deionised water
HSLISIn-situ particle counter for liquids
BioCaptMicrobial air impactor
FacilityProFacility monitoring system
DataAnalystSoftware for particle counters
AirSentry IIAirborne molecular contamination monitoring

Where is Particle Measuring Systems equipment used?

  • Pharmaceutical industry — cleanrooms, isolators, Annex 1
  • Semiconductors and microelectronics — contamination with 10–20 nm particles
  • Batteries — contamination control in production
  • Aerospace and optics — cleanrooms and monitoring
  • Ultrapure water — continuous monitoring of particles in liquids

How do we supply Particle Measuring Systems in Romania?

We can quote PMS particle counters, probes, filters, accessories and parts, supplied to order. Accessories arrive to order, usually in 1–4 weeks; configured instruments and monitoring systems may have a longer lead time, confirmed in the quotation. For a correct quotation, send us the application (air, liquid, microbiological), the minimum particle size, the sampling flow rate, the standards followed (ISO 14644, Annex 1) and the mode of use: portable, fixed or integrated. For parts, add the model and serial number of the counter.

The compliance of an installation with a given standard is established on the basis of the monitoring design and the validation of the system.

Frequently asked questions about Particle Measuring Systems

What products does Particle Measuring Systems make?

PMS makes airborne particle counters (Lasair Pro, Lasair III 110, IsoAir Pro, Airnet II, NanoAir 10), counters for liquids (Ultra DI, HSLIS), BioCapt microbial monitors, FacilityPro systems and software for cleanrooms.

How do I choose the counter by particle size and application?

For ISO cleanroom certification the Lasair III 110 is used at 0.1 µm, for continuous monitoring in isolators the IsoAir Pro, and for semiconductor equipment the NanoAir 10 at 10 nm. Send us the cleanroom class and the standard followed.

Do you supply PMS counters in Romania, in what lead time?

Yes, we supply to order. Accessories and parts come to order, usually in 1–4 weeks, and configured instruments and systems have a lead time confirmed in the quotation.

Can a Lasair Pro replace an older counter in an existing system?

It depends on the interface of the monitoring system and on the protocols; compatibility is confirmed after checking. Send the old model and the type of system, and we check before the quotation.

What data do you need for a quotation on a PMS particle counter?

The application, the minimum particle size, the flow rate, the standard (ISO 14644, Annex 1), whether it is portable, fixed or integrated into an isolator and, for parts, the model and serial number.

How do I request a Particle Measuring Systems quotation?

Send the Particle Measuring Systems code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 23 November 2026 · Sources: Particle Measuring Systems, Inc. (manufacturer documentation)