PR electronics supplier in Romania
For PR electronics we quote 5437 and 6437 temperature transmitters, 3100 6.1 mm converters, 9106 and 9116 barriers and 4511 interfaces; we need the full code from the module and the input and output type.
Who is PR electronics and what does it make?
PR electronics is a Danish manufacturer of signal conditioning modules for process and factory automation: temperature transmitters, intrinsically safe barriers, isolators and signal converters, communication interfaces and displays. The modules take the signal from resistance thermometers, thermocouples or other transducers and pass it on, galvanically isolated, to the PLC or to the distributed control system (DCS). For a quotation, send us the four-digit code and the letter from the module (for example 5437D or 9113B), the input and output type and any Ex certification required.
The temperature transmitters are mounted in the sensor head, on a rail or in the field. 6437 and 5437 are two-wire transmitters with HART 7 (compatible with HART 5), with an input for a resistance thermometer, thermocouple, resistance or bipolar mV voltage and with one or two real sensor inputs; 5437B has approval only for explosion-risk areas, according to the manufacturer's documentation. The 5450 series works on PROFIBUS PA profile 4.0, and 7501 is a field-mounted HART transmitter, programmed with optical buttons and usable in areas with explosive gases and dust. The 3101 (thermocouple) and 3102 (Pt100) converters have a narrow 6.1 mm housing and an accuracy better than 0.1% of the range, and the 3111, 3112 and 3113 variants are isolated, the last one with HART.
The intrinsically safe barriers of the 9000 series – the 9106 HART repeater, the 9107 HART driver, the 9113 temperature converter, the 9116 universal converter, the 9202 pulse isolator and the 9203 driver for solenoid valves and alarms – separate the loops in the Ex area from the control room. The 4000 series adds universal transmitters (4104, 4114, 4116), trip amplifiers (4131, 4179B) and current-to-frequency converters (4222, 4225), configured from the 4510 front panel or through the 4511 interface with Modbus and the 4512 Bluetooth variant. PR electronics gives a 5-year warranty on its products.
What do we supply from the PR electronics range?
| Product | Description |
|---|---|
| 6437 and 5437 HART transmitters | Two-wire temperature transmitters, with HART 7 and HART 5, an input for a resistance thermometer, thermocouple, resistance or bipolar mV and one or two real sensor inputs. They are mounted in the sensor head; 5437B has approval only for explosion-risk areas, according to the datasheet. |
| 7501 field transmitter | HART temperature transmitter mounted in the field, programmed with optical buttons, without opening the housing. It is intended for areas with explosive gases and dust and communicates through HART 7 and HART 5. |
| 3100 series of 6.1 mm | Narrow rail converters: 3101 for thermocouples and 3102 for Pt100, with an accuracy better than 0.1% of the range, plus the isolated variants 3111, 3112 and 3113 with HART. Suitable for panels with many channels. |
| 9000 series intrinsically safe barriers | The 9106 HART repeater, the 9107 HART driver, the 9113 temperature converter, the 9116 universal converter, the 9202 pulse isolator and the 9203 solenoid valve driver, mounted in the control room for the loops in the Ex area. |
Why PR electronics?
- Transmitters with two real sensor inputs (6437, 5437) — redundancy on the same temperature measuring point
- 6.1 mm converters (3100 series) — many channels in a panel with limited space
- Intrinsically safe barriers for HART, temperature, pulses and solenoid valves — the loop in the Ex area stays separate from the control room
- Configuration from the 4510 front or through 4511 with Modbus — the module is reprogrammed without a computer in the field
- 5450 series on PROFIBUS PA profile 4.0 — the temperature is sent directly on the field bus
Which PR electronics codes and series are requested most often?
| Code | Description |
|---|---|
| 6437A / 6437D | Two-wire temperature transmitter, HART 7, single or dual input |
| 5437A / 5437D | Two-wire temperature transmitter, HART 7 |
| 5437B | HART 7 temperature transmitter, explosion-risk area variant only |
| 5450A / 5450D | PROFIBUS PA profile 4.0 temperature transmitter |
| 7501 | Field HART transmitter, programming with optical buttons |
| 3101 | Converter for thermocouples, 6.1 mm housing |
| 3102 | Converter for Pt100, 6.1 mm housing |
| 3113 | Isolated temperature converter, with HART 7 |
| 9106B | Transparent intrinsically safe HART repeater |
| 9113B | Intrinsically safe temperature / mA converter |
| 9116B | Intrinsically safe universal converter |
| 9203B | Intrinsically safe driver for solenoid valves and alarms |
| 4116 | Universal transmitter from the 4000 series |
| 4511 | Modbus communication interface for the 4000 series |
Where is PR electronics equipment used?
- Petrochemicals and chemicals — intrinsically safe barriers between the Ex area and the control room
- Power plants and heating networks — HART transmitters on pipes and boilers
- Water treatment — isolation and conversion of 4–20 mA signals
- Factory automation — narrow converters in panels with many channels
- Food industry — temperature transmitters in the sensor head
How do we supply PR electronics in Romania?
We can quote PR electronics modules: temperature transmitters, intrinsically safe barriers, isolators, converters and the 4510 and 4511 configuration accessories. For a correct order, send us the four-digit code and the variant letter from the module, the sensor type and the temperature range, the output signal (4–20 mA, HART, PROFIBUS PA) and the Ex certification requirement. Modules can ship in 24–72 h when the item is in stock, locally or at the supplier, and the others arrive to order, usually in 1–4 weeks. The exact lead time is confirmed in the quotation.
The Ex approvals of a module with a different variant letter (A, B or D) are established on the basis of the full code on the label of the installed module.
Frequently asked questions about PR electronics
What does PR electronics make?
PR electronics makes signal conditioning modules in Denmark: HART, PROFIBUS PA and analogue temperature transmitters, intrinsically safe barriers from the 9000 series, isolators and universal converters from the 3000 and 4000 series, communication interfaces and displays.
How do I choose between a 5437 and a 6437 transmitter?
Both are two-wire transmitters with HART 7, a universal input and the option of two real sensor inputs. The difference lies in the variant and the approvals: the letter A, B or D in the code indicates the certification. Send us the installation area and the Ex requirement, and we choose the suitable variant.
What is the lead time for a PR electronics module?
Modules can ship in 24–72 h when the item is in stock, locally or at the supplier, and the others we supply to order, usually in 1–4 weeks. For large quantities of barriers or rare variants, depending on the specification, the lead time may be longer.
Which PR electronics module replaces an old transmitter in the panel?
We start from the code on the old module, the sensor type, the range and the output, plus the mounting (sensor head or rail). If the module is no longer made, we check which current variant from the 5000, 6000 or 3100 series has the same inputs, outputs and approvals, before proposing it.
What data do I send for a quotation on PR electronics intrinsically safe barriers?
The type of field signal (4–20 mA with HART, temperature, pulses, solenoid valve control), the number of channels, the Ex area and the gas group, the supply voltage of the panel and whether you need configuration through 4510 or 4511.
How do I request a PR electronics quotation?
Send the PR electronics code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: PR electronics (manufacturer documentation)