Pulsar Measurement supplier in Romania

For Pulsar Measurement we quote dB and dBi transducers, dBR and PULSAR REFLECT radar, Ultra 4 and Ultra 5 controllers and AVFM 6.1 and PDFM 6.1 flow meters; we need the medium, the measuring distance, the required outputs and the mounting area.

Founded in 1986 · Headquarters: Malvern, United Kingdom

Request a quote

Who is Pulsar Measurement and what does it make?

Pulsar Measurement is a British manufacturer of level and flow instruments, based in Malvern and active since 1986. The programme starts from ultrasonic and radar transducers, which measure level without contact with the product, and extends to pump controllers and open channel flow meters. Typical applications are pumping stations, sumps, wastewater basins, silos and process tanks.

The dB transducers (from 3 to 40 m) and dBi, with HART output (digital data on the 4–20 mA loop), Modbus or Profibus, use DATEM echo processing (digital adaptive tracking of echo movement), which follows the real echo of the surface and ignores fixed echoes in crowded wells, dusty silos or tanks with agitators; the effective beam angle is usually about 3 degrees. The dBR series and the two-wire PULSAR REFLECT sensor are radar, suited to foam, vapours and high temperatures. IMP is a compact sensor with built-in controller, and IMP I.S. has versions for explosive atmospheres, according to the manufacturer's documentation, with PVDF wetted parts. The Ultra 4 and Ultra 5 controllers (five relays, range from 125 mm to 40 m) handle pump control and volume and flow measurement, while UltraTWIN and DLT 2.0 solve differential level, for example in front of mechanical screens.

For flow, dBMACH3 is the open channel transducer, AVFM 6.1 measures velocity and level with a submerged sensor, and PDFM 6.1 is a portable clamp-on Doppler flow meter, for liquids with solids or bubbles. The Quantum 3, Ultimate and Zenith pump controllers complete the range. The quotation starts from the device code or, for new installations, from the measuring distance, the medium and the required outputs.

What do we supply from the Pulsar Measurement range?

ProductDescription
dB and dBi transducersUltrasonic transducers for liquids and solids, with distances from 3 to 40 m, DATEM processing and options for immersion shields, PVDF or intrinsic safety. The dBi are smart, two-wire, with HART, Modbus or Profibus output and volume conversion for preset tank shapes.
Radar level sensors (dBR, PULSAR REFLECT)dBR is a non-contact FMCW (frequency-modulated continuous wave) radar transducer, for foam, vapours, chemicals and high temperatures. PULSAR REFLECT is a two-wire radar sensor, hermetically sealed, with a 6° beam angle, configuration through a web application and Bluetooth with a settable range up to 36 m.
Ultra, UltraTWIN, DLT 2.0 and pump controllersUltra 4 and Ultra 5 combine pump control, level, volume and flow, with 4 or 5 relays. UltraTWIN and DLT 2.0 work with two sensors for differential level. Quantum 3 is a pump controller for small stations, without PLC programming, and Ultimate and Zenith are other pump controllers.
dBMACH3, AVFM 6.1, PDFM 6.1 and FarSight flow metersdBMACH3 is for open channels, AVFM 6.1 measures velocity and level with a submerged sensor, in pipes from 150 mm, PDFM 6.1 is a portable clamp-on Doppler flow meter, IP67, and FarSight measures velocity at a distance, up to 15 m above the water.

Why Pulsar Measurement?

  • DATEM echo processing — ultrasonic transducers follow the real surface and ignore fixed echoes in wells, silos and tanks with agitators
  • Ultrasonic and radar in the same family — dB and dBi for most liquids and solids, dBR and REFLECT for foam, vapours and high temperatures
  • Industrial interfaces — dBi is available with HART, Modbus or Profibus, and the transducers can be connected to Ultra controllers without changing the system
  • Version for Ex zones — IMP I.S. has ATEX versions according to the manufacturer's documentation, with PVDF wetted parts for aggressive media
  • From level to flow — pump controllers, open channel flow meters and the FarSight velocity sensor, without contact with the water

Which Pulsar Measurement codes and series are requested most often?

CodeDescription
dB3 / dB6Non-contact ultrasonic level transducers
dBi HARTSmart ultrasonic transducer, HART output
dBi ModbusSmart ultrasonic transducer, Modbus output
dBi ProfibusSmart ultrasonic transducer, Profibus output
dBRNon-contact radar level transducer
PULSAR REFLECTRadar level sensor, two-wire
IMPCompact ultrasonic sensor with built-in controller
IMP I.S.IMP sensor in version for explosive atmospheres, 3 to 10 m
IMP LiteIMP sensor for simple level measurement
Ultra 4Multifunction controller with four relays
Ultra 5Multifunction controller with five relays, 125 mm to 40 m
UltraTWINTwo-channel differential level controller
DLT 2.0Differential level transmitter with two sensors
Quantum 3Smart pump controller
dBMACH3Ultrasonic transducer for open channels
AVFM 6.1Velocity-area flow meter with submerged sensor

Where is Pulsar Measurement equipment used?

  • Wastewater and pumping stations — level in wells, pump control, open channels
  • Chemicals and process tanks — radar and ultrasonics for media with vapours or foam
  • Silos and solid materials — level in quarries, mines and dusty silos
  • Energy and pharmaceutical — level and volume in process tanks
  • Environment and hydrology — velocity and flow in open channels and rivers

How do we supply Pulsar Measurement in Romania?

We can quote dB, dBi and dBR transducers, IMP and PULSAR REFLECT sensors, Ultra and pump controllers, and AVFM 6.1 and PDFM 6.1 flow meters and FarSight sensors. We supply to order, usually in 1–4 weeks, and depending on the specification the lead time can be longer for Ex or multi-relay configurations. For a correct quotation, send us the medium and the maximum measuring distance, the temperature, the type of tank or channel, the required outputs (4–20 mA, HART, Modbus, relays) and, if you are replacing a sensor, the name on the label.

The measuring range of a sensor is established from the medium, the obstacles in the beam path and the mounting conditions.

Frequently asked questions about Pulsar Measurement

What does Pulsar Measurement make?

Pulsar Measurement makes ultrasonic and radar level sensors, level and pump controllers, open channel flow meters and portable Doppler flow meters. The company has operated since 1986 and is based in Malvern, in the United Kingdom; the instruments are used in wastewater, chemicals and solid materials.

When do I choose radar and when ultrasonics for level?

Ultrasonics from the dB and dBi series cover most liquids and solids, while dBR or REFLECT radar is chosen for foam, vapours, high temperatures or atmospheric variations. Send us the medium, the maximum distance, the temperature and the presence of foam or condensation, and the suitable technology is confirmed in the quotation, based on the manufacturer's documentation.

Do you supply Pulsar products in Romania, and how fast?

Yes, we supply to order, usually in 1–4 weeks; an item can ship in 24–72 h when the item is in stock, locally or at the supplier. Depending on the specification, the Ex version or one with additional relays can take longer.

Can I replace an old Pulsar sensor with a new series?

Pulsar sensors can be connected to any of the controllers in the same family, but each case is checked against the name on the label, the cable length, the output type and the mechanical connection. Send us the data and a photo of the installation before ordering.

What data do I send for a quotation on a level sensor?

Send the measured medium, the maximum distance from the sensor to the surface, the temperature and pressure, the type of tank or well, the required outputs (4–20 mA, HART, Modbus, relays), the power supply and whether the area is classified Ex. For flow, add the size of the channel or pipe.

How do I request a Pulsar Measurement quotation?

Send the Pulsar Measurement code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Pulsar Measurement (manufacturer documentation)