Rheonik supplier in Romania
Coriolis mass flowmeters with Omega tubes
Headquarters: Odelzhausen, Germany
Who is Rheonik and what does it make?
Rheonik is a German maker of Coriolis mass flowmeters, with its headquarters and factory at Odelzhausen, in Bavaria. The company has worked on Coriolis measurement since 1983 and designs its sensors in its own "Omega" technology: two measuring tubes, set in oscillation by two electromagnetic coils, in which the Coriolis force slightly deflects the tubes when liquid or gas flows through them. The torsional oscillation design allows thicker pipe walls and robust bodies.
The manufacturing programme is organised around the RHM series sensors, from RHM 015 to RHM 160, sized by nominal mass flow, and the RHE transmitters with "Assurance Factor", a measurement status indicator: RHE 21 and 42 for field mounting in Ex zones, RHE 26, 27 and 28 for panel, DIN rail or universal mounting, RHE 45 and 49 in a compact integral version. RHM 06, for example, is offered in 316L, Super Duplex, Alloy C22 or tantalum and covers temperatures from -196 to +350 °C. For high pressures there are measuring versions for up to 1722 bar (chemical injection and liquefied gas applications).
Rheonik is found in inhibitor injection in the oil and gas industry, at hydrogen refuelling stations, in resin or adhesive dosing installations and on ship loading lines. Quoting needs exact process data: fluid, flow, pressure, temperature, wetted material, Ex zone and the outputs required, because the sensor and the transmitter are chosen together.
What do we supply from the Rheonik range?
| Product | Description |
|---|---|
| RHM sensors | Family of Coriolis sensors with Omega tubes, from RHM 015 to RHM 160, over increasing mass flow ranges, in materials from 316L stainless steel to tantalum or Alloy C22. |
| RHE transmitters | Transmitters with Assurance Factor (RHE 21, 26, 27, 28, 42, 45, 46, 49) for field, panel, DIN rail or compact integral mounting, with pulse, frequency and status outputs. |
| High-pressure Coriolis | Versions for chemical injection, hydrogen and CNG, with measurement stated for up to 1722 bar, used at wells and refuelling stations. |
| Very low flows | Small sensors for fast filling and precise dosing, for example refrigerant in the manufacture of HVAC installations. |
Why Rheonik?
- Omega tube technology — two tubes with torsional oscillation, as the basis for thick walls and high pressures
- Pressure of up to 1722 bar — for chemical injection and liquefied gases
- Temperatures from -196 to +350 °C — range stated for the RHM 06 sensor, with wetted materials such as tantalum or Super Duplex
- Transmitters with Assurance Factor — RHE 21–49, for field, panel or integral mounting, with versions for Zone 2 and Ex
- API volume corrections and net crude oil calculation available — on the RHE 28 transmitter, for oil transfer
Which Rheonik codes and series are requested most often?
| Code | Description |
|---|---|
| RHM 015 | Small sensor from the RHM series (< 1.2 kg/min) |
| RHM 02 | Small Coriolis sensor |
| RHM 03 | Small Coriolis sensor |
| RHM 06 | Coriolis sensor, -196 to +350 °C, several wetted materials |
| RHM 10 | Coriolis sensor for medium flows |
| RHM 15 | Coriolis sensor for medium flows |
| RHM 40 | Coriolis sensor for high flows |
| RHM 160 | Coriolis sensor for very high flows |
| RHE 21 | Ex d transmitter for field mounting |
| RHE 26 | Transmitter for panel or DIN rail |
| RHE 27 | Transmitter for panel mounting |
| RHE 28 | Universal transmitter, IP67, Zone 2 |
| RHE 42 | Ex de transmitter for field mounting |
| RHE 45 | Compact integral transmitter |
Where is Rheonik equipment used?
- Oil and gas — chemical injection, well control, custody transfer
- Hydrogen and energy — refuelling stations and H2 production
- Marine — measurement of fuel loaded and consumed
- Plastics and chemicals — dosing of viscous or abrasive liquids
- Food and automotive — dosing, filling and refuelling racks
How do we supply Rheonik in Romania?
We can quote Rheonik RHM sensors, RHE transmitters and connecting cables for replacements or new projects. The equipment is supplied to order, usually in 1–4 weeks; configured systems with special materials or high pressures can take longer. For a quotation, the full code on the sensor and transmitter nameplates, the fluid, the minimum and maximum flow, the working pressure and temperature, the wetted material and the zone classification are useful. The exact lead time is confirmed in the quotation.
The sensor is recommended from the real process data, and custody transfer certifications are confirmed separately, for each model.
Frequently asked questions about Rheonik
What products does Rheonik make?
Rheonik, from Odelzhausen (Bavaria), makes Coriolis mass flowmeters with Omega tubes: RHM series sensors and RHE transmitters with Assurance Factor. They are used in chemical injection, hydrogen, oil transfer, dosing and food.
How do I choose the size of the RHM sensor?
The RHM designation indicates the size, and each model has a nominal mass flow range. The choice is made by the maximum flow and the pressure loss accepted. Send us the fluid, the minimum and maximum flow and the pressure.
Do you supply Rheonik flowmeters in Romania, and in what time?
Yes. Sensors and transmitters are supplied to order. To order, usually 1–4 weeks, sometimes longer when special materials, high pressures or certifications are involved; a quotation with the exact lead time follows after the code is checked.
Can I change the transmitter without changing the sensor?
Often yes, but it depends on the sensor generation and the original transmitter. Compatibility is confirmed only after checking. Send the full sensor code, the transmitter model and the outputs used.
What do I need to send for a quotation on a Rheonik Coriolis flowmeter?
The code on the nameplate (for a replacement), or, for a new project, the fluid, density and viscosity, minimum and maximum flow, pressure, temperature, wetted material, Ex zone and the electrical outputs required.
How do I request a Rheonik quotation?
Send the Rheonik code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Rheonik Messtechnik GmbH (manufacturer documentation)

