Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Rosemount supplier in Romania

Rosemount makes pressure transmitters and process instrumentation for heavy industries

Founded in 1956 · Headquarters: Shakopee, USA

Request a quote

Who is Rosemount and what does it make?

Rosemount was founded in 1956 near Minneapolis and is today a brand for industrial process measurement instrumentation — pressure, temperature and level — with the current headquarters of the product line in Shakopee, Minnesota. From the range we can quote the 4051S, 3051S, 3051 and 2051 series pressure transmitters, the Rosemount wireless pressure gauge, non-contact radar level transmitters (3408), guided wave radar (3308) and the wireless vibrating level detector (2160), plus the 3144P temperature transmitter.

What sets the Rosemount lines apart is precision matched to position in the range: the 4051S series has a reference accuracy of up to 0.025%, while the basic 3051 has 0.04% accuracy — the customer chooses the performance level according to how critical the measurement loop is. All pressure transmitters cover 4-20 mA HART, WirelessHART, Foundation Fieldbus or PROFIBUS protocols, depending on the model, which makes integration into an existing automation system easier, regardless of the supplier.

For installations in Romania, Rosemount means access to the exact equivalent of a transmitter already fitted on a process loop, or to a wireless solution where running cable would be costly.

What do we supply from the Rosemount range?

ProductDescription
4051S and 3051S Series Pressure TransmittersDifferential, gauge or absolute pressure transmitters, with a reference accuracy of up to 0.025% and a 20-year warranty (4051S), or 15-year (3051S). The protocols differ by model (4051S: HART and Bluetooth; 3051S: HART, WirelessHART and Foundation Fieldbus), with process-alert diagnostics and loop/line integrity verification. Typical application: pressure and flow measurement via a differential pressure element on critical control loops.
3051 and 2051 Series Pressure TransmittersBasic variants of the pressure family, with a reference accuracy of up to 0.04% (3051) or 0.05% (2051), suitable where the performance of the S series is not required. They cover the same measurement types — gauge, absolute and differential. Typical application: pressure monitoring on utilities and auxiliary circuits without extreme accuracy requirements.
3408 and 3308 Radar Level Transmitters3408 is a non-contact level radar, while 3308 uses guided wave radar technology (direct contact through a probe), both for continuous level measurement in liquids, solids or slurries. They are complemented by the 2160 wireless vibrating detector for level alarm points, without additional cabling. Typical application: level monitoring on process or storage tanks.
3144P Temperature TransmitterTemperature transmitter with a dual-compartment housing, compatible with thermocouples and resistance thermometers, with a sensor-transmitter matching function that improves the accuracy of the final measurement. It is used for critical temperature control and in safety applications in industries such as food, mining and refining.

Why Rosemount?

  • Reference accuracy of up to 0.025% on the 4051S series, with a 20-year warranty
  • Multiple communication protocols — HART, WirelessHART, Foundation Fieldbus or PROFIBUS, depending on the model
  • Non-contact measurement on the radar level transmitters — 3408 and 3308
  • Built-in diagnostics — process alerts and signal line integrity verification on most models
  • Wireless installation — the wireless pressure gauge and the 2160 level detector remove the need for cabling

Which Rosemount codes and series are requested most often?

CodeDescription
4051SPressure transmitter, 0.025% accuracy, 20-year warranty
3051SPressure transmitter, 0.025% accuracy, 15-year warranty
3051Pressure transmitter, 0.04% accuracy, 5-year warranty
2051Pressure transmitter, 0.05% accuracy
Wireless Pressure GaugeWireless pressure gauge for remote monitoring
2160Wireless level detector, vibrating fork technology
3408Non-contact radar level transmitter
3308Wireless level transmitter, guided wave radar
3051SALWireless level transmitter
3144PTemperature transmitter with sensor-transmitter matching

Where is Rosemount equipment used?

  • Chemicals and processing — pressure and level measurement on reactors and columns
  • Oil and gas, refining — pressure transmitters on critical process lines
  • Water treatment — level and pressure monitoring in treatment plants
  • Food and pharmaceutical industry — temperature transmitters for critical control
  • Power generation and marine applications — process instrumentation on auxiliary circuits

How do we supply Rosemount in Romania?

Rosemount instrumentation is not kept on our shelf, so we work from the manufacturer's public data and state in advance what we can confirm for the requested code. We bring in Rosemount transmitters, on order, typically in 1–4 weeks. For an accurate quotation we need the full model code (for example 3051CD or 2051TG), the measurement type — gauge, differential, level or temperature — and the communication protocol required by your automation system. We do not keep the range on our own shelf, and the lead time can be longer, depending on the brand and on the specifications.

HART or Fieldbus parameterisation of a Rosemount transmitter, specific to the customer's system, is established on the basis of the documentation of the existing automation loop.

Frequently asked questions about Rosemount

What products does Rosemount deal with?

Rosemount, a process instrumentation brand, makes pressure, level (radar or vibrating technology) and temperature transmitters, used for monitoring and control in industrial automation loops in chemicals, oil and gas, energy and the food industry.

How do I choose the right Rosemount pressure transmitter?

The choice depends on the measurement type — gauge, absolute or differential —, on the accuracy required by the loop and on the communication protocol of your system (HART, WirelessHART, Foundation Fieldbus or PROFIBUS); send the existing model code so we can verify the equivalent.

What is the difference between the Rosemount 3051S and 3051 series?

The 3051S series offers a reference accuracy of up to 0.025%, with advanced diagnostics, while the basic 3051 has an accuracy of 0.04%; the choice depends on how critical the measurement loop is for your process.

Do you supply Rosemount transmitters in Romania and in what time?

We bring in Rosemount transmitters on order, typically in 1–4 weeks from confirmation; we do not keep the range on our own shelf, and the exact lead time depends on the availability confirmed by the manufacturer for the model requested.

What information do you need for a Rosemount transmitter quotation?

Send the full code of the existing model or, for a new installation, the measurement type desired, the pressure or level range and the communication protocol required, so that we can confirm the suitable Rosemount variant for the order.

How do I request a Rosemount quotation?

Send the Rosemount code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Emerson, Wikipedia (manufacturer documentation)