Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

TDK RF Solutions supplier in Romania

For TDK RF Solutions we quote semi-anechoic chambers, the CAC-S compact chamber, IB, IP and IS series absorbers, HLP, PBA and MBA antennas and TDK Lab software; for a quotation we need the standards, the frequency band and the space available.

Founded in 1987 · Headquarters: Cedar Park, Texas, USA

Request a quote

Who is TDK RF Solutions and what does it make?

TDK RF Solutions is an American manufacturer based in Cedar Park, Texas, founded in 1987, specialising in equipment for electromagnetic compatibility (EMC) testing and for antenna measurement. A new product reaching the European market must pass radiated emission and immunity tests; for them a semi-anechoic chamber, absorbers, calibrated antennas and control software are needed. The company offers exactly these elements.

The chambers include 3 and 10 metre semi-anechoic variants, designed for radiated emissions and radiated immunity, chambers for antenna evaluation and the CAC-S compact chamber, measuring 7.5 × 4.0 × 3.0 m, for measurements between 26 MHz and 18 GHz, which can be built in many industrial or office buildings. The absorbers are made in ferrite-based or carbon-based series: IB, IP, IP-BX, ITF, IS, IS-SM (for oblique incidence) and IS-V.

The test antennas include the PBA-2030 and MBA-2060 (biconical), the high-power HBA-2030, the hybrid log-periodic HLP-2601 (26 MHz–1 GHz) and HLP-2603 (26 MHz–3 GHz) and the broadband antenna HPBA-2510 for immunity. The TDK Emissions Lab, Radiated Immunity Lab, Conducted Immunity Lab and Antenna Lab software controls the measurements. In Romania, the range is of interest to EMC test laboratories, to electronic equipment manufacturers and to the automotive industry.

What do we supply from the TDK RF Solutions range?

ProductDescription
Semi-anechoic and antenna EMC chambers3 m and 10 m semi-anechoic chambers for radiated emissions and immunity, chambers for evaluating wireless antennas and the CAC-S compact chamber, 7.5 m long, 4.0 m wide and 3.0 m high, for 26 MHz–18 GHz.
Radio-frequency absorbersSeries of absorbing tiles and pyramids: IB and IP use the magnetic losses of ferrite, IS and IS-SM use the ohmic losses of carbon, and ITF, IP-BX and IS-V are composite absorbers, based on polystyrene or foamed polyethylene.
PBA-2030, MBA-2060, HLP-2601, HLP-2603 and HPBA-2510 test antennasAntennas for emissions and immunity: biconical PBA-2030 (20–300 MHz) and MBA-2060 (20–600 MHz), hybrid log-periodic HLP-2601 (26 MHz–1 GHz) and HLP-2603 (26 MHz–3 GHz) and the HPBA-2510 power antenna for high field (25–100 MHz).
TDK Lab softwareControl packages for EMC tests: Emissions Lab for emissions in a shielded chamber, in an anechoic chamber or on an open area test site, Radiated Immunity Lab for anechoic chambers, TEM or GTEM cells, Conducted Immunity Lab and Antenna Lab.

Why TDK RF Solutions?

  • 3 and 10 metre semi-anechoic chambers — radiated emissions and radiated immunity in a controlled environment
  • CAC-S compact chamber of 7.5 × 4.0 × 3.0 m for 26 MHz–18 GHz — can be built in an industrial or office building
  • Absorbers based on ferrite, carbon or combinations (IB, IP, ITF, IS-V) — the lining is matched to the frequency band of the chamber
  • HLP-2603 hybrid log-periodic antennas for 26 MHz–3 GHz — wide coverage for emissions and immunity with a single antenna
  • Emissions Lab and Radiated Immunity Lab software — control from the same family for emissions, immunity and antennas

Which TDK RF Solutions codes and series are requested most often?

CodeDescription
CAC-SCompact semi-anechoic EMC chamber, 26 MHz–18 GHz
3 m semi-anechoic3 metre semi-anechoic chamber
10 m semi-anechoic10 metre semi-anechoic chamber
IBFerrite absorber
IPPolystyrene and ferrite based absorber
IP-BXCarbon and ferrite composite absorber
ITFComposite absorber with resistive film and ferrite
ISFoamed polyethylene and carbon based absorber
IS-SMAbsorber for oblique incidence
IS-VCarbon and ferrite composite absorber
PBA-2030Precision biconical antenna, 20–300 MHz
MBA-2060Metrology biconical antenna, 20–600 MHz
HBA-2030High-power biconical antenna
HLP-2601Hybrid log-periodic antenna, 26 MHz–1 GHz
HLP-2603Hybrid log-periodic antenna, 26 MHz–3 GHz
HPBA-2510High-power broadband antenna, 25–100 MHz

Where is TDK RF Solutions equipment used?

  • EMC test laboratories — radiated emissions and radiated immunity
  • Electronics manufacturers — pre-compliance in an in-house chamber
  • Automotive industry — immunity tests to an electromagnetic field
  • Telecommunications — characterisation of antennas and wireless devices

How do we supply TDK RF Solutions in Romania?

We can quote TDK RF Solutions EMC chambers, absorbers, test antennas and software, after the test standards are clarified. These are systems designed to order, so depending on the specification the lead time may be longer, and we set the date in the quotation. For catalogue antennas and accessories we supply to order, usually 1–4 weeks. For a correct request we need the applicable standards, the frequency range, the size of the object under test, the space available in the building and, for antennas, the model code.

The size of the chamber needed for a given product depends on the standard, on the measurement distance and on the object under test, and is established from this data.

Frequently asked questions about TDK RF Solutions

What does TDK RF Solutions make?

TDK RF Solutions makes in Texas anechoic and semi-anechoic chambers for EMC, radio-frequency absorbers, test antennas, electric field generators, stripline systems, monitoring equipment and control software for emission, immunity and antenna measurement tests.

How do I choose between a 3 m and a 10 m chamber?

The measurement distance required by the emissions standard and the size of the product under test set the size of the chamber. The 3 m chamber is usual for small products and the 10 m one for large equipment. Send us the standard, the size of the object and the space available.

Do you supply TDK RF Solutions equipment in Romania and in what time?

Yes, TDK RF Solutions equipment is supplied to order. The chambers are systems designed to order, and the lead time may be longer. For catalogue antennas the lead time is usually 1–4 weeks, with the exact date in the quotation.

Can I replace degraded absorbers in an existing chamber?

Yes, absorbers are replaced by zones. To identify the series, send us the type and size of the existing tiles, the frequency band of the chamber and photos of the tiles, so we can check which current series fits, with compatibility confirmed case by case.

What data do I send for a test antenna quotation?

Specify the frequency band, the type of test (emissions or immunity), the power required for immunity, the standard and the existing antenna, if you have one. Based on these we propose from among the biconical antennas, the hybrid log-periodic ones and the power ones, together with the cables and supports needed for mounting in the chamber.

How do I request a TDK RF Solutions quotation?

Send the TDK RF Solutions code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: TDK RF Solutions Inc. (manufacturer documentation)