Sampling, gas conditioning and odorization

Founded in 1954 · Headquarters: Sugar Land, Texas, USA

Request a quote

Who is Welker and what does it make?

Welker is an American company from Sugar Land, Texas, founded in 1954, which started by inventing and building devices for the oil and gas industry. Today it designs, machines and tests its products in the same factory and holds over 90 American patents. The range has three main directions: sampling (natural gas, crude oil and light liquids), gas conditioning for analyzers and instruments, and natural gas odorization.

For sampling, the solutions range from composite and spot samplers for natural gas to constant-pressure cylinders (for example CP-2, which keeps the sample at line pressure from collection to the laboratory), probes, inFlow crude oil samplers and containers. Conditioning includes the LE-5 liquid eliminator, the IRM probe regulator with manual insertion, the SCHS-3 heated system for analyzer protection and the CleanFlow system, which delivers clean, dry pipeline gas to pneumatic instruments, emergency shutdown valves and control valves. For odorization, the ECOsystem with pumpless vapor injection doses the odorant in proportion to the flow, including for biomethane.

Products of this type appear at gas custody transfer and regulating stations, at compressor stations, in refineries and at metering stations, that is, wherever a wrong sample or a pneumatic instrument fed with wet gas affects billing or safety. They are ordered on the basis of process conditions and code.

What do we supply from the Welker range?

ProductDescription
Composite and spot samplers for natural gasEquipment that collects either successive samples over a time or flow interval (composite) or a sample at a given moment (spot), with measures to reduce the risk of liquid carry-over.
Constant-pressure cylinders (CP-2)Cylinders for collecting, transporting and keeping samples of natural gas and light liquid hydrocarbons at line pressure, for laboratory analysis.
Analyzer conditioning (LE-5, IRM, SCHS-3)Liquid eliminator, probe regulator with manual insertion and heated pressure and temperature conditioning system, to protect chromatographs and analyzers from free liquids and condensate.
ECOsystem and CleanFlowECOsystem is a pumpless vapor-injection odorization system, proportional to the flow; CleanFlow conditions pipeline gas for pneumatic instruments and process valves.

Why Welker?

  • Sample kept at line pressure — CP-2 constant-pressure cylinders, from collection to laboratory analysis
  • Complete conditioning chain — LE-5 for liquids, IRM for sample pressure, SCHS-3 for heating, ahead of the chromatograph
  • CleanFlow for instrument gas — cleaning and drying of pipeline gas for shutdown and control valves, compressor stations, refineries
  • ECOsystem for odorization — pumpless dosing in proportion to the flow, for small, large or variable flows
  • Complete manufacture in Texas — design, machining and testing at a single manufacturer, with over 90 American patents

Which Welker codes and series are requested most often?

CodeDescription
CP-2Constant-pressure cylinder for samples of gas and light liquid hydrocarbons
LE-5Liquid eliminator for conditioning the gas sample
IRMProbe regulator with manual insertion for analyzers
SCHS-3Compact heated sample conditioning system
ECOsystemPumpless vapor-injection odorization system
CleanFlowNatural gas system for pneumatic instruments
inFlowCrude oil sampler for pipelines
inFlow ACECrude oil sampler for collecting samples in a composite system

Where is Welker equipment used?

  • Natural gas distribution — odorization at custody transfer stations and networks
  • Gas transmission — sampling and conditioning at metering stations
  • Refineries and process plants — clean, dry instrument gas
  • Crude oil production and transport — crude oil samplers and containers
  • Biomethane and biogas — odorization and gas analysis

How do we supply Welker in Romania?

We can quote Welker equipment for sampling, sample conditioning and odorization, as well as parts for existing systems. Supply is to order; usually 1–4 weeks for replacement items, while configured systems (odorization skids, instrument gas systems) may have a longer lead time. For a correct quotation we need: the composition of the gas or liquid, the working pressure and temperature, the minimum and maximum flow, the pipe diameter and connections, the required standards (for example CRN, ATEX) and, for odorization, the type of odorant and the gas flow. The exact lead time is confirmed in the quotation.

Parts for older models are checked separately, by code, before the quotation.

Frequently asked questions about Welker

What product range does Welker have?

Welker, a company from Sugar Land (Texas) founded in 1954, makes equipment for sampling natural gas, crude oil and light liquids, conditioning systems for analyzers, CleanFlow instrument gas systems and odorization equipment (ECOsystem). It holds over 90 American patents.

How do I choose between a spot and a composite sampling system?

The spot sampler takes a sample at a given moment, useful for routine checks; the composite one gathers samples over a time or flow interval, so it reflects a gas whose composition changes. The choice depends on the standard being followed and on the variation of the gas. Tell us the measuring point and the pressure.

Can you supply Welker equipment in Romania, and in what lead time?

Yes, Welker equipment is supplied to order. For parts and accessories the usual lead time is 1–4 weeks; configured systems, such as odorization systems, may have a longer lead time, confirmed in the quotation after the configuration is checked.

Can I replace an existing regulator or liquid eliminator?

It can be checked, case by case: the connection, the inlet pressure, the sample flow and the materials matter. Send the code from the existing part (for example LE-5 or IRM), the working pressure and the type of analyzer, and we confirm the suitable version.

What data do you need for a quotation for an ECOsystem odorization system?

Send the minimum and maximum gas flow, the pressure at the station, the type of odorant and the required dosage, the type of station (custody transfer station, network, industrial consumer, biomethane), the available power supply and the Ex zone requirements. With this data we identify the suitable configuration.

How do I request a Welker quotation?

Send the Welker code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.