For Wistro we quote forced-ventilation units for electric motors in the IL, ILI and IL2 series, variants for single-phase, three-phase and 24 V DC voltages, low-temperature variants and fans for explosion-risk zones; the item is identified by motor and size.
Who is Wistro and what does it make?
Wistro makes industrial fans and forced-ventilation units, known in German as Fremdlüfteraggregate. A forced-ventilation unit is a fan with its own motor, fitted on the cover of an electric motor, which cools it independently of its speed. It is a cooling solution for motors where the motor's own fan is no longer sufficient.
The main series are IL, ILI and IL2. The units are usually supplied ready to install and are chosen according to the size of the motor they cool; the ILI and IL2 series together cover motor sizes from 160 to 560. The degree of protection is IP66, the approvals are CE, UKCA and UL, and the declared service life (MTTF) is 40,000 hours. The units can be used and stored between -20 °C and +60 °C, and the low-temperature variants between -40 °C and +60 °C. They can be supplied single-phase at 115 V or 230 V, three-phase at 115 V or 230 V or 400 V and at 24 V DC.
For explosion-risk zones, special fans are used, not the standard units, with an ATEX declaration of conformity and IECEx certificates. The flow rate and noise level data are given for motors with 2 and 4 poles. For a quotation, the motor manufacturer and type, the size, the voltage, the number of poles and the working environment matter.
What do we supply from the Wistro range?
| Product | Description |
|---|---|
| IL and ILI forced-ventilation units | Fan with its own motor, fitted on the electric motor it cools, generally supplied ready to install. Together with IL2, they cover motor sizes from 160 to 560, with IP66 and a declared service life of 40,000 hours. |
| IL2 series | Series of the same family as IL and ILI, with the same general data: IP66, CE, UKCA and UL approvals. The choice is made according to the motor size and the available voltage. |
| Variants for explosion-risk zones | For explosion-risk zones, special fans are used instead of the standard units. There is an ATEX declaration of conformity, IECEx certificates and wiring diagrams for three-phase variants at 230 V. |
| Variants for different voltages and temperatures | Single-phase supply at 115 V or 230 V, three-phase at 115 V, 230 V or 400 V and 24 V DC. The low-temperature variants work between -40 °C and +60 °C, and the standard ones between -20 °C and +60 °C. |
Why Wistro?
- Forced-ventilation units of the IL, ILI and IL2 series — motor cooling with its own fan, fitted on the motor
- Motor sizes from 160 to 560 with the ILI and IL2 series — they suit medium and large power motors
- IP66 degree of protection and declared service life of 40,000 hours — maintenance-free bearings under normal conditions
- Various voltages, including 24 V DC and three-phase 400 V — the same series suits different networks
- Low-temperature variants and variants for explosion-risk zones — for installations with an outdoor environment or with dust and gases
Which Wistro codes and series are requested most often?
| Code | Description |
|---|---|
| IL | Series of forced-ventilation units for electric motors |
| ILI | Series of forced-ventilation units for motor sizes 160–200 and 355–560 |
| IL2 | Series of forced-ventilation units, variant of the IL series |
| Bg 160 IL1 | Motor size 160 in the IL1 series, with characteristic curves |
| Bg 250 IL2 | Motor size 250 in the IL2 series, with characteristic curves |
| Bg 355 IL1 | Motor size 355 in the IL1 series, with characteristic curves |
| 3~400V | Three-phase variant at 400 V, 4 poles |
| 3~230V | Three-phase variant at 230 V, 2 and 4 poles, with ATEX and IECEx versions |
| 1~230V | Single-phase variant at 230 V with capacitor motor or shaded-pole motor |
| 24V DC | 24 V DC variant |
Where is Wistro equipment used?
- Electric motor cooling — units fitted on the motor, generally supplied ready to install
- Installations with electric motors where self-cooling is not enough — fan with its own motor
- Woodworking and coal milling — variants with a dust protection cover
- Environments with fibres — installations where fibres settle on the fan
- Explosion-risk zones — installations with gases or dust, with special variants
How do we supply Wistro in Romania?
We can quote Wistro forced-ventilation units for electric motors, variants for explosion-risk zones and spare parts for existing units. For an accurate quotation, send the motor manufacturer and type, the size (Bg), the number of poles, the voltage and frequency, the Wistro code from the current unit and the environment it works in. A photo of the unit nameplate helps. The units are supplied to order, usually in 1–4 weeks; they can ship in 24–72 h when the item is in stock, locally or at the supplier. Depending on the variant, the lead time may be longer.
For units used in explosion-risk zones we specify in the quotation the variant suited to the zone category, based on the installation data you provide.
Frequently asked questions about Wistro
What is a Wistro forced-ventilation unit?
A fan with its own motor, fitted on an electric motor to cool it independently of its speed. The series are IL, ILI and IL2, with IP66 and a declared service life of 40,000 hours. They suit motors where self-cooling is not enough.
How do I choose the right unit for my motor?
According to the motor size (Bg), the number of poles, the supply voltage and the working environment. Between sizes 160 and 560 the ILI and IL2 series are used, depending on size. Send us the motor manufacturer and the size or the Wistro code from the old unit, and we check the variant.
Do you supply Wistro units in Romania, and how quickly?
The units are ordered and arrive usually in 1–4 weeks. Units can ship in 24–72 h when the item is in stock, locally or at the supplier. For special variants, for example for explosion-risk zones, the lead time may be longer.
Can I replace a Wistro unit fitted on an existing motor?
Yes, if we identify the series. We need the code from the unit nameplate, the motor size, the voltage and the number of poles. On replacement the direction of rotation must be respected, otherwise cooling is considerably reduced. We check the suitable variant in the quotation.
What do I send for a quotation on a forced-ventilation unit?
The motor manufacturer and type, the size (Bg), the number of poles, the voltage and frequency, the ambient temperature and whether the environment contains dust, fibres or explosive gases. If the installation has particular supply features, mention them, so that we can check the variant.
How do I request a Wistro quotation?
Send the Wistro code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.