Weight Indicators and Transmitters
The weight indicator takes the weak signal from the load cells, amplifies it, converts it to digital and displays the weighed value. The transmitter does the same without a local display, sending the weight to a programmable controller or a control system through an analogue output or an industrial bus. The choice depends on the number of cells connected, the speed of the process and how the value reaches the operator or the automation system.
Weighing electronics supply the cells with a stable voltage, measure variations of the order of microvolts, filter out noise and apply corrections: tare, zero, calibration with test weights or by calculation and, on some models, multi-point linearisation. Panel, bench or field indicators provide a display, keys and output contacts for setpoints, while transmitters are mounted in boxes or on a rail and communicate with the automation system.
What counts when choosing is the number of cells that can be connected, input sensitivity, conversion rate, digital filters, the type of interfaces and the degree of protection. For fast processes, such as dosing, a high acquisition rate reduces the stopping error. For installations subject to legal metrology, the instrument must have the appropriate approval, and the metrological parameters are secured by a seal or a change counter. For areas with an explosion risk there are versions with suitable protection or intrinsically safe barriers, and for several cells a summing junction box with signal trimming adjustment is used.
How to choose
Number and type of cells connected
Check whether the instrument supplies the number of cells in the system, in the four-wire or six-wire configuration, or whether it connects to a summing junction box.
Conversion rate and filtering
Dynamic processes, such as dosing or filling, require a high acquisition rate; static tank weighing benefits from strong filters against vibration.
Interface to automation
Choose the suitable output: analogue 4–20 mA or 0–10 V, serial port or industrial bus, according to the controller that receives the weight.
Digital inputs and outputs
Contacts for setpoints, dosing start and stop, tare or reset simplify small systems with no dedicated controller.
Calibration and approval
Calibration without test weights is useful on large tanks, where they cannot be applied; for commercial transactions ask for an approved instrument with metrological sealing.
Protection rating and enclosure
Panel front, wall enclosure or stainless steel enclosure are chosen according to the mounting method and the risk of water, dust or washdown.
Classified zone
If the electronics operate in an explosive environment or connect cells in a classified zone, ask for the version with suitable protection or intrinsically safe barriers.
What to send for a quotation
- The number and capacity of the load cells connected
- The application: static weighing, dosing, filling or process control
- The type of output needed: analogue, serial or industrial bus
- The number of digital inputs and outputs
- The mounting method: panel, wall, rail or field
- Whether the system is subject to legal metrology or is in a classified zone
Typical applications
- Platforms and tanks with a local display
- Transmitting weight to controllers
- Dosing and filling processes
- Weighing stations with setpoints and alarms
Maintenance and spare parts
Weighing electronics need little intervention, but installation conditions matter. Periodically check the zero and the calibration with a check weight, make sure the cable shielding is connected correctly and that the enclosure does not take in moisture. After replacing a cell or after mechanical changes, repeat the calibration. Keep a copy of the instrument's parameters, for quick recovery after a fault or a replacement, and note the date of each calibration.
Brands we quote for this product type
Frequently asked questions
What is the difference between a weight indicator and a weight transmitter?
The indicator has a display and keys, so it can be used directly by the operator for reading, taring, calibration and sometimes for simple process commands. The transmitter has no display or only a minimal one and is designed to send the weight to a programmable controller, a regulator or a supervisory system through an analogue output or an industrial bus. In many installations they are used together, the transmitter for automation and a separate indicator for the operator on site.
Can I calibrate a tank weighing system without test weights?
Yes, in many cases. Calibration by calculation uses the rated sensitivity of the cells, stated on the certificate, and the rated load, and the result is sufficient for processes where legal accuracy is not required. The ideal method, when possible, remains calibration with a reference mass or with a quantity of product weighed beforehand on another installation, because it also checks the mechanical structure, not only the electronics. The choice depends on the accuracy wanted and access to the system.
Which interface should I choose for connecting to a programmable controller?
For simple process values the analogue output, 4–20 mA, is sufficient, robust against interference and easy to integrate. If you need weight, status, alarms and tare commands on the same link, an industrial bus or a serial port provides more information with fewer wires. Choose the protocol supported by your controller and check the update rate, which is important in dosing, where delay in the value affects stopping accuracy.
How long does delivery take and what data is needed for a quotation?
If the item is in stock, locally or at the supplier, delivery usually takes 24–72 h; for versions brought in to order, the lead time is usually 1–4 weeks, and depending on brand and specification it can take longer. Send the number of cells and their capacity, the type of application, the interface wanted, the mounting method and, if there is one, the model of the instrument you are replacing.
Updated: 2026-11-20