Pressure Gauges and Indicators
A pressure gauge is the instrument that displays the pressure of a fluid in an installation locally, mechanically through a pointer on a dial or digitally through an electronic display. It is used for direct reading by the operator, where an electrical signal sent to a control system is not necessarily needed.
The mechanical pressure gauge works on the principle of the Bourdon tube, the diaphragm or the capsule, which deforms in proportion to the pressure and moves a pointer on the dial; the digital pressure gauge uses a pressure sensor and shows the value on a screen, sometimes with an additional electrical output for remote transmission. Versions with a glycerine-filled case reduce pointer vibration and extend service life in installations with pressure pulsations, such as those near compressors or piston pumps.
A good pressure gauge for industrial use is recognised by its stated accuracy class, the material of the wetted parts (stainless steel for aggressive fluids, brass for general applications), a dial diameter suited to the reading distance and a case protection class against moisture and dust. For viscous fluids or fluids with particles a diaphragm seal is recommended, and for explosive atmospheres, ATEX 2014/34/EU certification of the digital version; the reference standard for construction is EN 837.
How to choose
Pressure range to be measured
It is chosen so that the normal working pressure falls in the lower half of the scale, not near its end, to protect the mechanism and read correctly with accuracy.
Accuracy class required
For indicative reading a usual class is enough; for processes where pressure directly affects product quality a higher accuracy class is chosen.
Material compatibility with the fluid
Stainless steel resists aggressive or food-grade fluids, brass is enough for air and non-corrosive water; the wrong choice leads to rapid corrosion of the wetted parts of the instrument.
Presence of pulsations or vibrations
Near piston compressors or pumps with pulsating flow, a pressure gauge without damping fails quickly; the liquid-filled case version lasts much longer.
Connection type and mounting position
The threaded connection must match the installation port exactly, and the mounting position (radial, axial) affects the reading angle for the operator.
Need for a transmitted electrical signal
If the value must also be sent to a control system, not just read locally, a pressure transmitter or a digital pressure gauge with an electrical output is needed, not a purely mechanical one.
What to send for a quotation
- The pressure range to be measured and the fluid handled
- The desired material for the wetted parts, depending on how aggressive the fluid is
- The type and size of the threaded connection
- Dial diameter and mounting position (radial or axial)
- Presence of vibrations or pressure pulsations at the installation point
- Quantity and desired deadline
Typical applications
- Industrial installations
- Compressors
- Hydraulic systems
- Field monitoring
- Pumping stations
Maintenance and spare parts
The most stressed component is the internal mechanism (the Bourdon tube or the diaphragm), which tires over time under pulsating pressures or repeated peaks above the nominal range. Periodic accuracy checks against a reference standard are recommended, together with watching for any fogging in the dial (a sign of leakage) and replacing pressure gauges that do not return to zero after the pressure is released.
Brands we quote for this product type
- AEP transducers
- Afriso
- AMETEK U.S. Gauge
- ARMANO Messtechnik
- Asahi Gauge
- Ashcroft
- Badotherm
- Dwyer
- Esders
- Fairchild
- Fantinelli
- Greisinger
- Kimo Instruments
- Labom
- Marsh Bellofram
- Nagano Keiki
- NOSHOK
- Nuova Fima
- Orange Research
- Palmer Wahl Instrumentation
- Reotemp Instruments
- Rixen Messtechnik
- Sensys (Sensor System Technology)
- SUKU
- Teledyne Hastings Instruments
- Testo
- Trerice (H.O. Trerice)
- Webtec
- Weiss Instruments
- WIKA
- Winters Instruments
- Wöhler
Frequently asked questions
What is the difference between a mechanical pressure gauge and a pressure transmitter?
The mechanical pressure gauge displays the pressure locally on a dial, for reading by the operator, without an electrical signal; the pressure transmitter converts the pressure into an electrical signal sent to a PLC or a SCADA system, with no display of its own in the basic versions. Many installations use both, one for reading, the other for automation.
How do I choose the pressure range of an industrial pressure gauge?
Start from the maximum working pressure of the installation and choose a range so that the normal operating value falls in the lower half of the scale. Choosing a range too close to the actual pressure shortens the life of the internal mechanism.
What must be sent for a quotation for industrial pressure gauges, and how long does delivery take?
We need the pressure range, the fluid handled, the connection type and the desired material. Delivery is to order, typically 1–4 weeks, depending on the manufacturer, and shorter for standard versions already produced in series.
Can standard pressure gauges be used on installations with strong vibrations?
It is not recommended; a pressure gauge without glycerine or other liquid damping fails quickly because of the continuous oscillation of the pointer. For such installations, liquid-filled case versions are chosen, designed specially for vibrating environments.
Updated: 2026-11-12