Orange Research supplier in Romania
For Orange Research we quote 1201, 1303, 1502 and 1831 differential pressure gauges, 2020, 2220 and 2500 flow meters and 1516, 1020 and 1536 cryogenic indicators; we need the series on the dial, the range, the line pressure and the medium.
Founded in 1963 · Headquarters: Milford, Connecticut, USA
Who is Orange Research and what does it make?
Orange Research is an American manufacturer based in Milford, Connecticut, active since 1963, which makes differential pressure gauges, switches and transmitters, magnetic-indicator flow meters and level indicators for cryogenic tanks. The common element is the magnetically coupled sensor: a piston or a diaphragm pushed by the differential pressure moves a magnet, and the magnet moves the indicator pointer through the magnetic coupling, with the sensor separate from the indicator. The same sensor can receive switches, a relay or a transmitter with a 4–20 mA or 0–5 V output.
The devices are chosen by sensor type. The piston series, 1201, 1203 and 1303, are for liquids at high line pressures, with ranges between 0–5 and 0–1000 psid (differential psi). The diaphragm series, 1502, 1516, 1518 and 1831, cover gases and liquids, and the 1831 goes down to 0–5 inches of water column. The 1204, 1504 and 1514 variants have housings for explosive atmospheres, Class I, Division 1. The 1002 and 1020 miniature models are intended for equipment manufacturers (OEM), and the PVC models have no metal parts in contact with the liquid. The flow meters go from the 2020/2021, with a fixed orifice, at 0–4 to 0–40 GPH (gallons per hour), to the 2220, 2320 and 2420 series with variable area, up to 30 GPM (gallons per minute), and to the 2500, with a nozzle and differential pressure gauge, up to 200 GPM.
Typical cases are the monitoring of hydraulic and process filters, level and flow measurement, heat exchangers and bulk cryogenic tanks for liquid nitrogen, oxygen and argon. For a quotation we start from the series and range on the dial or, for new installations, from the line pressure, the medium and the pressure difference to be monitored.
What do we supply from the Orange Research range?
| Product | Description |
|---|---|
| Piston differential pressure gauges (1201, 1203, 1303) | Devices for liquids at high line pressure, with a body machined from a single block. The 1201 has a range of 0–5 to 0–150 psid, the 1203 has a NEMA 4X housing for switches or a transmitter, and the 1303 measures up to 1000 psid. They are used in filtration, hydraulics and heat exchangers. |
| Diaphragm differential pressure gauges (1502, 1516, 1518, 1831) | Devices for gases and liquids. The 1502 has a rolling diaphragm up to 300 psid, the 1516 measures 0–1 psid at a line pressure of 1500 psig, the 1518 is used for compound measurements, and the 1831 reaches 0–5 inches of water column. Each can receive a switch, a relay or a transmitter. |
| Flow meters and flow switches (2020/2021, 2220–2423, 2500) | Flow meters with a magnetic indicator on the dial. The 2020/2021 have a fixed orifice for low flows, the 2220, 2320 and 2420 have variable area for liquids and gases, and the 2500 uses a non-clogging nozzle and a differential pressure gauge for 0–5 to 0–200 GPM. |
| Cryogenic level indicators (1516, 1020, 1536) | Differential pressure gauges for the level in cryogenic liquid tanks. The 1516 has 70–150 mm dials and versions with a switch or a transmitter, the 1020 is the compact version, and the 1536 is designed as a replacement indicator on bulk tanks. |
Why Orange Research?
- Magnetically coupled sensor — piston or diaphragm, separate from the indicator, so the same body receives switches, a relay or a transmitter
- High line pressure — the 1203 and 1303 piston series work up to 5000 psig, and the 1204 for Ex areas also up to 5000 psig
- Very low ranges — the 1831 series goes down to 0–5 inches of water column, for filters, level and flow at low pressure
- Housings for Ex areas — 1204, 1504 and 1514 in Class I, Division 1, with NEMA 3, 4X, 7, 9 and 12 protection
- Flow and level from the same family — flow meters with fixed orifice, variable area or nozzle, plus indicators for cryogenic tanks
Which Orange Research codes and series are requested most often?
| Code | Description |
|---|---|
| 1201 | Piston differential pressure gauge, 0–5 to 0–150 psid |
| 1203 | Piston, NEMA 4X housing for switches or a transmitter |
| 1303 | Piston, up to 1000 psid |
| 1502 | Rolling diaphragm, up to 300 psid |
| 1516 | Diaphragm, 0–1 psid at 1500 psig |
| 1518 | Diaphragm, compound differential measurements |
| 1831 | Diaphragm, from 0–5 inches of water column |
| 1204 | Piston in Class I, Division 1 housing, up to 150 psid |
| 1504 | Diaphragm in Class I, Division 1 housing, up to 300 psid |
| 1514 | Diaphragm in Class I, Division 1 housing, 0–1 psid |
| 1002 | Miniature piston model, 1–100 psid |
| 1020 | Miniature diaphragm model, up to 25 inches of water column |
| 2020 / 2021 | Fixed orifice flow meter, 0–4 to 0–40 GPH |
| 2220 / 2320 / 2420 | Variable area flow meters, up to 30 GPM |
| 2500 | Differential nozzle flow meter, up to 200 GPM |
| 1536 | Cryogenic level indicator for bulk tanks |
Where is Orange Research equipment used?
- Hydraulics and filtration — indicating filter clogging at high line pressures
- Industrial gases — level in cryogenic nitrogen, oxygen and argon tanks
- Oil and gas — differential pressure gauges in housings for explosive atmospheres
- Heat exchangers and coolers — monitoring of pressure drop and flow
- Water treatment — PVC models for corrosive liquids, with no metal parts in contact with the medium
How do we supply Orange Research in Romania?
We can quote Orange Research differential pressure gauges, switches and transmitters, magnetic-indicator flow meters and cryogenic level indicators, starting from the series on the dial. We bring in the devices to order, usually in 1–4 weeks, and the versions with Ex housings or with custom configurations may take longer, depending on the specification. For an accurate quotation, send us the series and range from the device or, for a new installation, the line pressure, the temperature, the medium, the pressure difference to be monitored, the ports, the desired signal (switch, 4–20 mA, 0–5 V) and the installation area.
The version with custom ports or dial is established based on the exact series of the device.
Frequently asked questions about Orange Research
What does Orange Research make?
Orange Research makes differential pressure gauges, switches and transmitters, magnetic-indicator flow meters and flow switches, and level indicators for cryogenic tanks. The company has worked since 1963 in Milford, Connecticut, and makes both standard models and custom configurations.
How do I choose between a piston sensor and a diaphragm sensor?
The piston suits liquids at high line pressures, for example the 1203 and 1303 series. The diaphragm is used for gases or liquids at small differences, down to 0–5 inches of water column on the 1831 series. Send us the medium, the line pressure and the expected pressure difference.
Do you supply Orange Research devices in Romania, and how fast?
Orange Research devices are sourced to order, usually in 1–4 weeks. An Orange Research item can ship in 24–72 h when the item is in stock, locally or at the supplier. Ex housings and custom dials may take longer, depending on the specification; the exact lead time is in the quotation.
Can I replace an existing cryogenic indicator with the 1536 model?
The 1536 model is designed as a replacement indicator on bulk cryogenic tanks, and the fit is checked based on the old model, the ports and the range. Send us the data from the dial and a photo of the installation.
What data should I send for a differential pressure gauge quotation?
Send the series and range from the device or, for a new installation, the medium, the line pressure, the temperature, the pressure difference to be monitored, the ports, the desired signal (switch, 4–20 mA or 0–5 V) and whether the area is classified for explosion hazard.
How do I request a Orange Research quotation?
Send the Orange Research code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Orange Research Inc. (manufacturer documentation)