PAC supplier in Romania
For PAC we quote the ElemeNtS and NSure sulphur and nitrogen analysers, the OptiDist 2 distillation unit, the Icon process analysers for distillation and flash point and the ViscoPro 2000 viscometer, depending on the test standard and the product analysed.
Headquarters: Houston, Texas, USA
Who is PAC and what does it make?
PAC is an American manufacturer of laboratory and process analysers for petroleum, petroleum products and petrochemicals, headquartered in Houston, Texas. The range is grouped by the properties that refineries and control laboratories require: total sulphur and nitrogen, distillation, flash point, cold properties (pour point, cloud point and freezing point), viscosity, density and electrical conductivity of fuels, to which are added detectors for gas chromatography.
For sulphur and nitrogen, ElemeNtS is the modular laboratory analyser, with ultraviolet fluorescence (UVF) and chemiluminescence (CLD), in a vertical or horizontal configuration for solid, liquid, gas and LPG samples, and NSure continuously measures total sulphur and nitrogen in gas, LPG and liquid streams, at blending, in refineries, in petrochemicals and in the monitoring of wastewater and emissions. SeNSe² is the chemiluminescence detector for chromatographs. For distillation, OptiDist 2 complies with ASTM D86, EN ISO 3405 and IP 123, and the Icon process analyser works between 0 and 430 °C on 20 mL samples. The Icon flash point analyser works in an explosion-proof enclosure, according to the manufacturer's documentation, and ViscoPro 2000 measures viscosity online. Emcee 1152 measures the conductivity of fuels according to ASTM D2624.
Such instruments work at refineries, at petroleum product depots and blending stations, in fuel quality control laboratories, for renewable fuels and in petrochemical process streams. The choice depends on the test standard, the product analysed and the way of working, laboratory or online, which is why a quotation starts from the required method and the existing instrument.
What do we supply from the PAC range?
| Product | Description |
|---|---|
| ElemeNtS and NSure | Total sulphur and total nitrogen analysers: ElemeNtS for the laboratory, with UVF and CLD detection, for solid, liquid, gas and LPG samples, and NSure for continuous online measurement in gas, LPG and liquid streams, for refineries and petrochemicals. |
| OptiDist 2 and the Icon distillation analyser | OptiDist 2 is the atmospheric laboratory distillation unit with thermosiphon cooling, and the Icon analyser performs small-scale distillation in the process, between 0 and 430 °C, with up to 128 new results every 10–20 minutes. |
| Flash point and cold properties analysers | Icon Flash Point Analyzer, in an explosion-proof enclosure, for process; OptiFlash Pensky-Martens, for the laboratory, up to 400 °C; OptiCPP for cloud point and pour point, down to −95 °C, fully automatic. |
| ViscoPro 2000 and Emcee 1152 | ViscoPro 2000 is the process viscometer with proportional-integral control and RS232 and RS485 ports; Emcee 1152 is a portable, intrinsically safe conductivity meter for hydrocarbon fuels, according to ASTM D2624. |
Why PAC?
- Total sulphur and nitrogen on the same technical platform — ElemeNtS for the laboratory and NSure for the process use UV fluorescence and chemiluminescence
- Flash point analyser in an explosion-proof enclosure — according to the manufacturer's documentation, with internal chambers for following the spark without opening the enclosure
- Distillation to common standards — OptiDist 2 covers ASTM D86, D1078, D850, EN ISO 3405, ISO 918 and IP 123, among others
- Process distillation at 0–430 °C — the Icon analyser works on 20 mL samples and reaches the final boiling point in 10–15 minutes
- Adjustable online viscosity — ViscoPro 2000 has 13 standard measuring ranges, a memory of 1,000 points and up to 40 fluid settings
Which PAC codes and series are requested most often?
| Code | Description |
|---|---|
| ElemeNtS | Laboratory analyser for total sulphur and nitrogen |
| NSure | Online analyser for total sulphur and nitrogen |
| SeNSe² | Chemiluminescence detector for chromatographs |
| OptiDist 2 | Atmospheric laboratory distillation unit |
| Icon Distillation Analyzer | Process distillation analyser, 0–430 °C |
| Icon Flash Point Analyzer | Flash point analyser in an explosion-proof enclosure |
| Icon Pour Point Analyzer | Pour point analyser for process |
| Icon Viscosity Analyzer | Viscosity and viscosity index analyser |
| Icon Cetane Number Analyzer | Cetane number analyser |
| OptiFlash Pensky-Martens | Laboratory flash point analyser |
| OptiCPP | Cloud point and pour point, automatic |
| ViscoPro 2000 | Process viscometer with control |
| Emcee 1152 | Portable conductivity meter for fuels |
| Emcee 1140 | Micro-separometer for fuels |
| 70Xe Series | Cold properties and flow analysers |
Where is PAC equipment used?
- Refineries and petrochemicals — sulphur, nitrogen, distillation and flash point in process streams
- Petroleum product depots and blending stations — continuous control when blending fuels
- Quality control laboratories — distillation, cold properties and viscosity by standardised methods
- Renewable fuels — biodiesel, renewable diesel and sustainable aviation fuel
- Environment — total sulphur and nitrogen in wastewater and in emissions
How do we supply PAC in Romania?
We can quote PAC laboratory and process analysers for sulphur and nitrogen, distillation, flash point, cold properties and viscosity. We supply the equipment to order; the lead time is usually 1–4 weeks, and depending on the specification it can be longer. For a correct quotation, send us the test standard required (ASTM, EN ISO or IP), the product analysed, the measuring range, whether the instrument is for the laboratory or for the process, the installation area (with or without explosion hazard) and the model of the existing instrument. The exact lead time is confirmed in the quotation.
The laboratory or process version is decided only after the test standard and the product analysed are known.
Frequently asked questions about PAC
What does PAC make?
PAC makes, from its base in Houston, laboratory and process analysers for petroleum products: total sulphur and nitrogen, distillation, flash point, cold properties, viscosity, conductivity and detectors for gas chromatography. The range is aimed at refineries, petrochemicals, fuel depots and control laboratories.
When do I choose online NSure instead of laboratory ElemeNtS for sulphur and nitrogen?
NSure is chosen when sulphur and nitrogen are followed continuously in the gas, LPG or liquid stream, for process control, and ElemeNtS when samples reach the laboratory, including solids and heavy liquids. Tell us the product, the concentration range and the reference method to identify the version.
How long does delivery of a PAC analyser to Romania take?
The analysers are supplied to order, usually in 1–4 weeks; depending on the specification, the lead time can be longer, especially for process analysers in an explosion-proof enclosure. The exact lead time is confirmed in the quotation.
How do you check whether a newer PAC analyser can replace an old one?
We start from the model and series of the existing instrument, the test standard, the product analysed and the process or laboratory connections. Equivalence is confirmed once these data have been compared; a photograph of the nameplate and the method used speed up the check.
What data do I send for a quotation on a flash point analyser?
Send the product tested, the standard (for example Pensky-Martens or Cleveland), the temperature range, whether the instrument is for the laboratory or for the process and the classification of the installation area. For the Icon process analyser, the ATEX or IECEx requirement of the installation also matters.
How do I request a PAC quotation?
Send the PAC code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: PAC L.P. (manufacturer documentation)

