Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

OVAL Corporation supplier in Romania

Industrial flowmeters for liquids, gases and steam

Founded in 1949

Request a quote

Who is OVAL Corporation and what does it make?

OVAL Corporation is a Japanese manufacturer of industrial flowmeters, founded in 1949 with the launch of the first volumetric flowmeter made in Japan. The range covers six measuring principles — volumetric, Coriolis, vortex, ultrasonic, turbine and thermal mass — for liquids, gases and steam, alongside peripheral electronic instruments and calibration services. For customers in Romania we can bring in individual flowmeters from these families, based on the model and the measuring principle required.

The ULTRA OVAL series (including ULTRA UF-II) is a volumetric flowmeter, optionally available with an automatic temperature compensator and HART communication, used for measuring liquids. For mass flow, ALTIMASS2 Type U applies the Coriolis principle, suited to viscous fluids or mixtures where density varies. The range is completed by MASFLO OVAL2, a thermal mass flowmeter for gases, and EXDELTA ST PAF5, a vortex flowmeter for steam and gases at high temperatures.

For refineries, chemical platforms and utilities in Romania, OVAL Corporation covers situations where the measuring principle must be chosen according to the exact type of fluid — viscosity, gas content or temperature — not just the pipe size.

What do we supply from the OVAL Corporation range?

ProductDescription
ULTRA OVAL / UF-II — volumetric flowmeterOval gear volumetric flowmeter, used for the precise measurement of clean or slightly viscous liquids. The ULTRA UF-II series is optionally available with an automatic temperature compensator and HART communication for integration into automation systems. ULTRA OVAL Types S is a separate model, based on the same volumetric principle. For a quotation, state the nominal pipe diameter, the type of fluid measured and whether a HART output is needed for the existing control system.
ALTIMASS2 Type U — Coriolis flowmeterMass flowmeter based on the Coriolis principle, which measures the mass of the fluid directly, not the volume, eliminating the errors introduced by density variation with temperature or pressure. Suited to viscous fluids, emulsions or mixtures where a volumetric flowmeter would have large errors. To identify the correct size, the maximum and minimum process flow is needed, plus the type of fluid handled.
MASFLO OVAL2 and EXDELTA ST PAF5MASFLO OVAL2, in the FHC-FHD versions, is a thermal mass flowmeter for gases, in an explosion-proof design, intended for hydrogen and most gases (except strongly corrosive ones). EXDELTA ST PAF5 is a vortex flowmeter, suited to liquids, gases and steam, with working temperatures from -30 to +300 °C (optionally up to +460 °C). The choice between the two depends on the type of fluid (clean gas or steam) and on the temperature and pressure conditions in the installation.

Why OVAL Corporation?

  • Six measuring principles available — volumetric, Coriolis, vortex, ultrasonic, turbine and thermal mass
  • Automatic temperature compensator and HART communication available as options on the ULTRA UF-II series
  • ALTIMASS2 Coriolis flowmeter for viscous fluids where density varies over time
  • Over 75 years of flowmeter manufacturing in Japan, since the first volumetric model in 1949

Which OVAL Corporation codes and series are requested most often?

CodeDescription
UC-1Ultrasonic flowmeter
UF-II (ULTRA UF-II)Volumetric; optionally with automatic temperature compensator and HART
ULTRA OVAL Types SVolumetric flowmeter, basic version
ALTIMASS2 Type UCoriolis flowmeter
MASFLO OVAL2 FHC-FHDThermal mass flowmeter for gases
EXDELTA ST PAF5Vortex flowmeter for steam and gases
Debitmetru volumetricCategory of oval gear flowmeters
Debitmetru CoriolisCategory of mass flowmeters
Debitmetru vortexCategory of flowmeters for steam/gases
Debitmetru ultrasonicCategory of non-contact flowmeters
Turbine flowmeterCategory of mechanical flowmeters
Thermal mass flowmeterCategory of flowmeters for gases

Where is OVAL Corporation equipment used?

  • Refineries and petrochemicals — flow measurement of process liquids and gases
  • Chemicals — Coriolis flowmeters for viscous or corrosive fluids
  • Steam production and distribution — vortex flowmeters for steam lines
  • Utilities and energy — monitoring industrial fluid consumption

How do we supply OVAL Corporation in Romania?

We bring in OVAL Corporation flowmeters from the volumetric, Coriolis, vortex and thermal mass ranges to order, usually in 1–4 weeks. We rely on what the manufacturer's technical documentation confirms: we check the model requested or, if it is not known, the measuring principle suited to the fluid, the maximum and minimum process flow and whether a HART output is needed. Each lead time is confirmed separately for your order. State the type of fluid and the temperature/pressure conditions in the installation for a correct quotation.

Hydraulic sizing of the process line is outside our offer; we supply the OVAL Corporation flowmeter configured on the basis of the flow data confirmed by the customer.

Frequently asked questions about OVAL Corporation

What products does OVAL Corporation make?

OVAL Corporation makes industrial flowmeters for liquids, gases and steam, based on six different measuring principles — volumetric, Coriolis, vortex, ultrasonic, turbine and thermal mass — alongside peripheral electronic instruments for integrating them into automation systems.

How do I choose the right type of OVAL Corporation flowmeter for my application?

The choice depends on the type of fluid: for clean or slightly viscous liquids, ULTRA OVAL/UF-II covers the volumetric principle; for fluids with variable density, ALTIMASS2 uses the Coriolis principle; for steam or gases at high temperature, EXDELTA covers the vortex principle.

Does OVAL Corporation supply flowmeters in Romania?

We bring in OVAL Corporation flowmeters to order, usually in 1–4 weeks from confirmation of the model and the process conditions. The exact lead time depends on availability at the manufacturer.

What should I send for an OVAL flowmeter quotation?

The type of fluid measured, the maximum and minimum process flow, the nominal pipe diameter and the temperature and pressure conditions in the installation. This data allows the measuring principle and the correct size to be chosen before the quotation.

How do I request a OVAL Corporation quotation?

Send the OVAL Corporation code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: OVAL Corporation (manufacturer documentation)