Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

ABB Electrical supplier in Romania

Electrical distribution and protection equipment

Founded in 1988 · Headquarters: Zürich, Switzerland

Request a quote

Who is ABB Electrical and what does it make?

ABB Electrification is a major supplier of electrical switchboards and automation, on which a large part of industry relies. Tmax XT circuit breakers are frequently used for protection in industrial environments: the XT series comprises several frame sizes; the rated current and breaking capacity depend on the model and are confirmed from the ABB documentation. Ekip electronic trip units can be fitted with communication modules; the available protocols depend on the version.

ABB AF series contactors are intended for motor control and power circuits; service life depends on the model and is confirmed from the ABB documentation. They are frequently used on automotive production lines running 24/7, where their operating life is appreciated. The coils have a wide voltage range (24-500VAC/DC) and are compatible with electronic modules for soft-start and energy saving. ABB thermal overload relays have ambient temperature compensation; the setting ranges depend on the model and are confirmed from the ABB documentation.

System pro E power modular switchboards allow flexible configurations - high-capacity switchboards (4000A and above, with multiple sections) can be built for applications such as cement plants, using CuAl busbars. To IEC 61439-1&2; the IP degree of protection depends on the configuration and is confirmed from the ABB documentation.

What do we supply from the ABB Electrical range?

ProductDescription
ABB Tmax XT Circuit BreakersThe Tmax XT series is a family of moulded-case circuit breakers to IEC 60947-2; the rated current and breaking capacity depend on the frame size and are confirmed from the ABB documentation. Ekip electronic trip units provide L (long time, overload), S (short time, short circuit with time delay) and I (instantaneous, instantaneous short circuit) protections; measurement functions and communication protocols depend on the Ekip version and are confirmed from the ABB documentation. Programmable trip unit: 4 parameter sets switchable externally for different regimes (day/night/weekend). Configurable trip curves: I²t for selectivity with aM fuses, I⁴t for heavy-duty motor starting. Auxiliary contact with pre-alarm at 90% of rated current. Fixed or withdrawable mounting with truck for maintenance without disconnecting the busbars. Approvals according to the manufacturer's documentation, including marine approvals.
ABB AF ContactorsThe AF range is intended for utilisation categories AC-1 (resistive loads) and AC-3 (motors); rated currents, service lives and other data are confirmed from the ABB documentation for the chosen model. AgSnO2 (silver tin oxide) main contacts with arc chute and 10mm forced separation for short-circuit currents up to 14kA. AC 24-500V, DC 24-250V coils, consumption 5-150VA (AC) or 5-70W (DC), with an integrated economiser module that reduces consumption to 40% after pull-in. Side-mounted auxiliary contact blocks: 2NO+2NC up to 6NO+6NC.
ABB System pro E power Modular SwitchboardsModular system to IEC 61439-1&2 for 63-6300A configurations on the main busbar. Dimensions, busbar materials and degree of protection depend on the configuration and are confirmed from the ABB documentation. Forms of internal separation: form 1 (no separation), form 2b (busbars separated from the apparatus compartment), form 3b (complete separation including terminals), form 4b (total separation including busbars in each compartment).
ABB Thermal Overload RelaysABB thermal overload relays protect motors; the setting range and trip class are confirmed from the ABB documentation for the chosen model (IEC 60947-4-1). Automatic ambient temperature compensation -25°C to +60°C, accuracy ±5% at the set current. Manual function test with STOP button. 1NO+1NC auxiliary contact switching at 6A/250VAC for signalling and circuit control. Manual or automatic reset after trip (front selector). Direct mounting on AF9-AF400 contactors without additional wiring, spring or screw terminal connection. Visual indicator of the trip cause: thermal overload (red), instantaneous short circuit (yellow).

Why ABB Electrical?

  • Tmax XT circuit breakers; breaking capacity and rated voltage depend on the model and are confirmed from the ABB documentation
  • Ekip electronic trip units, with communication options depending on the version
  • AF contactors for motor control (category AC-3); construction details are confirmed from the ABB documentation
  • Modular System pro E power system to IEC 61439, configurations up to 6300A on the main busbar
  • Applicable standards: IEC 61439-1&2, IEC 60947-2 (circuit breakers), IEC 60947-4 (contactors)
  • Switchboard design software offered by the manufacturer; availability and conditions are confirmed with ABB

Which ABB Electrical codes and series are requested most often?

CodeDescription
Emax 3New-generation air circuit breaker
Emax 2Air circuit breaker for currents up to 6300A
FORMULAMoulded-case circuit breaker up to 630A
Tmax TMoulded-case circuit breaker, 320A to 3200A
Tmax XTHigh-performance moulded-case circuit breaker
Tmax PVCircuit breaker for direct current photovoltaic applications
SACE InfinitusSolid-state (semiconductor) circuit breaker for low-voltage DC networks
Ekip UPDigital protection unit for low voltage
SACE EmaxPrevious-generation air circuit breaker
MegamaxAir circuit breaker, previous generation (withdrawn from production); for equipment in service, consumables and spare parts are usually requested; replacement through a retrofit kit

Where is ABB Electrical equipment used?

  • Heavy industry (metallurgy, cement, mining)
  • Oil & Gas (refineries, petrochemicals, offshore platforms)
  • Utilities (power generation, electrical distribution)
  • Automotive (assembly plants, welding robots)
  • Food and beverage industry (food processing, beverages)
  • Pharmaceutical industry (drug manufacturing, clean rooms)
  • Data centres (UPS supply, redundant distribution)
  • Transport (metro, railways, airports)
  • Marine (ships, offshore platforms)
  • Commercial buildings (malls, offices, hospitals)

How do we supply ABB Electrical in Romania?

At Infinitrade we supply switchboards and switchgear to order. For common components, such as contactors or thermal relays, we can sometimes confirm 24–72 h when the item is in stock, locally or at the supplier, while for configured switchboards or more complex switchgear the lead time to order is usually 1–4 weeks, depending on the project. Firm delivery dates are given after a prior check with the supplier. For an accurate quotation, send us the single-line diagram or the switchgear list, the rated currents needed and the desired deadline — we reply with the real availability confirmed before the order.

Availability of circuit breakers and Ekip trip units is checked for each request; advanced configuration and on-site SCADA integration remain the responsibility of the installation integrator, while we supply the equipment.

Frequently asked questions about ABB Electrical

Which ABB circuit breaker should I choose for a high-power industrial switchboard?

The Emax 2 or Emax 3 series covers high currents, up to 6300A, and is the typical choice for the main distribution switchboards of an industrial hall. For secondary circuits with lower currents, a moulded-case circuit breaker from the Tmax T series is enough.

What is the difference between ABB Tmax T and Tmax PV circuit breakers?

Tmax T is the standard series of moulded-case circuit breakers for alternating current circuits. Tmax PV is the version specially adapted for direct current, used for protecting photovoltaic installations, where the electric arc on disconnection behaves differently from alternating current.

What current ratings and breaking capacities does the ABB Tmax XT7 circuit breaker have?

The Tmax XT7 is a moulded case circuit breaker for AC, rated 800, 1000, 1250 or 1600 A, 3 or 4 poles, 690 V, fixed or withdrawable. Its Icu breaking capacity at 415 V is 50 kA (S), 70 kA (H) or 120 kA (L). We confirm the full code with the quotation.

What information should I send for an ABB circuit breaker quotation?

It helps to state the rated current needed, the operating voltage, the type of network (alternating or direct current) and whether an Ekip digital protection unit is needed. These details allow the right choice between the Tmax, Emax or SACE Infinitus series.

What is the ABB Ekip UP digital unit?

It is an electronic protection and monitoring unit for low-voltage circuit breakers, which provides precise current and voltage measurements, as well as communication functions with the building or factory automation system.

How do I request a ABB Electrical quotation?

Send the ABB Electrical code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: ABB, ABB Ltd (manufacturer documentation)