For Alphasense we quote O2-A2, O2-A2-GLF and LFO2-A1 oxygen sensors, A and B electrochemical sensors for toxic gases, PIDX detectors and OPC-N3 particle counters; we need the code, the gas and the range.
Headquarters: Great Notley, Essex, United Kingdom
Who is Alphasense and what does it make?
Alphasense is a British manufacturer of gas and particle sensors, based at Great Notley, in Essex. The sensors are intended for manufacturers of portable or fixed gas detection instruments, flue gas analysers and environmental monitoring instruments, but they also appear as spare parts in existing instruments. The technologies are electrochemical, catalytic, optical (NDIR and PID) and spectroscopic, and the mechanical formats are A, B, C, D, G and H, which allows one sensor to be replaced with another of the same format.
For oxygen, the lead-free galvanic family O2-A2-GLF and O2-A2S-GLF has a service life of 2 years, two pins and zero bias, as a direct replacement for the O2-A2. The LFO2-A1 (0–30 %), LFO2-AL (up to 95 %) and LFO2-AH (0–2 %) are amperometric sensors with a service life of 5 years, with three pins. The classic models O2-A1, O2-A2, O2-A3, O2-C2 (for combustion) and O2-G2 (half height) remain in many installed instruments. For toxic gases, the A and B series offer more than 50 models for NH3, CO, Cl2, H2S, NO, NO2, SO2, HCN, HCl, H2 and others; the A+ and B+ series include integrated memory and a temperature sensor, with calibration data in the sensor. PIDX-A-020, -040, -200, -04K and -10K measure volatile organic compounds down to ppb level, and OPC-N3 and OPC-R2 count PM1, PM2.5 and PM10 particles.
The choice starts from the gas measured, the range, the mechanical format of the sensor, the service life and the type of power supply. For a quotation, the code on the sensor or the model of the instrument it is fitted into is needed.
What do we supply from the Alphasense range?
| Product | Description |
|---|---|
| Oxygen sensors | Lead-free galvanic O2-A2-GLF and O2-A2S-GLF, long-life amperometric LFO2-A1, LFO2-AL and LFO2-AH and the galvanic sensors with lead O2-A1, O2-A2, O2-A3, O2-C2 and O2-G2. The C2 has a carbon cloth filter for combustion measurement. |
| Electrochemical sensors for toxic gases | The A and B series, in the A+ and B+ version with integrated memory, for NH3, CO, Cl2, HCN, HCl, H2, H2S, NO, NO2, O3, PH3 and SO2. The D, G and H series are compact, for body-worn instruments. |
| NDIR, catalytic and PID sensors | NDIR sensors for carbon dioxide and methane, catalytic sensors for the lower explosive limit, and the PIDX-A-020, -040, -200, -04K and -10K photoionisation detectors for volatile organic compounds, with ranges from 0–20 ppm to 0–10,000 ppm. |
| Particle counters and support circuits | The OPC-N3 (0.35–40 μm, 24 size classes) and OPC-R2 (0.30–12.4 μm, 16 classes) optical particle counters, plus individual sensor boards, analogue circuits (AFE), boards with 4–20 mA output and caps for gas connection. |
Why Alphasense?
- Standard mechanical formats A, B, C, D, G, H — the sensor is identified by the letter and can be changed in an existing instrument
- Lead-free oxygen — the O2-A2-GLF has two pins and zero bias, as a direct replacement for the O2-A2
- More than 50 A and B electrochemical models — for ammonia, carbon monoxide, chlorine, hydrogen sulphide, nitrogen oxides and many other gases
- A+ and B+ sensors with memory — calibration data and temperature are stored in the sensor for plug-and-play fitting
- PID sensors and particle counters — PIDX for VOCs at ppb level, OPC-N3 and OPC-R2 for PM1, PM2.5 and PM10
Which Alphasense codes and series are requested most often?
| Code | Description |
|---|---|
| O2-A1 | Galvanic oxygen sensor, A format |
| O2-A2 | Galvanic oxygen sensor, A format |
| O2-A3 | Galvanic oxygen sensor, A format |
| O2-C2 | Oxygen sensor for combustion, with carbon filter |
| O2-G2 | Half-height oxygen sensor |
| O2-A2-GLF | Lead-free oxygen sensor, 2 years, zero bias |
| LFO2-A1 | Long-life oxygen sensor, 0–30 % |
| LFO2-AL | Long-life oxygen sensor, up to 95 % |
| LFO2-AH | Long-life oxygen sensor, 0–2 % |
| PIDX-A-020 | PID sensor, 0–20 ppm |
| PIDX-A-200 | PID sensor, 0–200 ppm |
| PIDX-A-10K | PID sensor, 0–10,000 ppm |
| PID-AH2 | Previous PID sensor, 0–40 ppm |
| PID-A15 | Previous PID sensor, 0–4000 ppm |
| OPC-N3 | Optical particle counter, 0.35–40 μm |
| OPC-R2 | Optical particle counter, 0.30–12.4 μm |
Where is Alphasense equipment used?
- Portable gas detectors — A, D and H sensors for confined spaces
- Fixed gas detection — A and B sensors in refineries, chemicals and utilities
- Flue gas analysers — C sensors for CO and O2
- Environmental monitoring — PIDX and OPC particle counters
- Semiconductors and manufacturing — sensors for toxic gases and oxygen
How do we supply Alphasense in Romania?
We can quote Alphasense gas sensors: oxygen, toxic gases, NDIR, catalytic and PID, as well as support boards and particle counters. We supply them to order; the lead time is usually 1–4 weeks, and for special ranges or versions it may be longer. For a correct quotation send the code on the sensor (for example O2-A2 or PIDX-A-040), the gas and the measuring range, the format and the model of the instrument it is fitted into. The exact lead time is confirmed in the quotation.
The compatibility of a sensor with a particular instrument depends on the format, the pins and the bias voltage, so it is confirmed after seeing the instrument model.
Frequently asked questions about Alphasense
What does Alphasense make?
Alphasense, from Great Notley (United Kingdom), makes electrochemical, catalytic, NDIR and PID gas sensors and optical particle counters, intended for manufacturers of detection instruments, flue gas analysers and environmental monitoring instruments. The sensors are also used as spare parts.
How do I choose an Alphasense oxygen sensor for an existing instrument?
We start from the sensor fitted: the O2-A2 can be replaced directly with the lead-free O2-A2-GLF, with the same A size and zero bias, but only after the instrument has been checked. If the instrument works with 3 pins and bias, the choice is made from the LFO2 series. Send the old code and the instrument model.
Do you supply Alphasense sensors in Romania, and how long does it take?
Yes, to order, usually in 1–4 weeks. Sensors can ship in 24–72 h when the item is in stock, locally or at the supplier. Special ranges or small series may take longer, and the exact lead time appears in the quotation.
What data should I send for a replacement toxic gas sensor?
Send the code on the sensor, the gas, the measuring range, the format (A, B, D, G or H) and the instrument model. For A+ and B+, the integrated memory also matters. A replacement with a different code is confirmed after comparing the format, the pins and the sensitivity.
Can I order a PID sensor for measuring VOCs at ppb level?
Yes, the PIDX series has five ranges, from 0–20 ppm (PIDX-A-020) to 0–10,000 ppm (PIDX-A-10K). For low levels the first ranges are used, for safety the large ones. Tell us the reference gas, the range and the instrument it is fitted into, and we identify the suitable code.
How do I request a Alphasense quotation?
Send the Alphasense code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.