Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Capacitec supplier in Romania

Non-contact capacitive displacement and clearance measurement sensors

Headquarters: Ayer, Massachusetts, USA

Request a quote

Who is Capacitec and what does it make?

Capacitec is an American company based in Ayer, in the state of Massachusetts, specialising in non-contact capacitive displacement and distance sensors, intended for measurements where a mechanical probe cannot reach or cannot withstand the conditions. Since the second half of the 1980s it has supplied systems for slot die coating, extrusion, aerospace, power generation and semiconductors. Its probes are small, with diameters of the order of 4.75 mm, and can operate in extreme environments: from −272 °C to 1000 °C, in high vacuum, in magnetic fields of up to 5 tesla and under intense radiation.

The electronics family is called Capteura and is modular: amplifiers and racks from the 200, 210 SCP, 508 SW, 516 SW and 520 series, the latter designed for linearity and low noise in displacement, distance and parallelism measurements. The probes are grouped by shape: button, cylindrical, threaded, thin and spring-contact. For portable work there is Gapman, a battery-powered instrument that measures gaps of up to 150–200 micrometres and replaces classic feeler gauges, with a 10,000-point recorder.

It is a range for specific applications: it appears in aircraft turbines and engines, on coating or extrusion lines, in semiconductor equipment and in test laboratories. Requests are almost always for the probe, cable and amplifier together, because the assembly is calibrated as a system and generations are not mixed.

What do we supply from the Capacitec range?

ProductDescription
Capacitive displacement probesNon-contact probes in button, cylindrical, threaded and thin versions, for displacement, distance and clearance measurements in tight spaces or in extreme temperature, vacuum or radiation environments.
Capteura amplifiersSignal conditioning modules in the 200, 210 SCP, 508 SW, 516 SW and 520 series, with modular racks for displacements, distances and parallelism, designed for low noise and stability.
Gapman — portable clearance measurementPortable, battery-powered instrument that measures clearances of up to 150–200 µm, including between conductive parts and composite materials, with 10,000-point recording in the Gen3 version.
Parallelism systems and LiniGageSystems with 3–6 sensors for measuring parallelism and flatness, plus LiniGage, a custom system for realigning the eccentricity of an aircraft engine rotor after rebuilding.

Why Capacitec?

  • Capacitive probes that withstand temperatures from −272 °C to 1000 °C, vacuum, strong magnetic fields and radiation — for environments where other sensors fail
  • Small 4.75 mm probe with a wide measuring range and cables of about 7 m with small calibration variations
  • Modular Capteura electronics — amplifiers and racks from the 200, 210, 508, 516 and 520 series for different configurations
  • Portable Gapman — measures gaps of 150–200 µm without the subjectivity of feeler gauges, with a data recorder
  • Parallelism systems with 3–6 sensors — for plates, wafer holders and work tables

Which Capacitec codes and series are requested most often?

CodeDescription
Capteura 200 SeriesModular amplifier for displacement and distance
210 SCPCapteura 210 SCP amplifier
508 SWCapteura 508 SW amplifier
516 SWCapteura 516 SW amplifier
Capteura 520 SeriesAmplifier for displacement, distance and parallelism
Gapman Gen3Portable clearance measuring instrument, 10,000-point recorder
Gapman Gen4Gen4 generation of the Gapman portable instrument
GapMaster 3Clearance measuring instrument from the Gapman range
LiniGageRotor eccentricity realignment system
BarGrafxDisplay for clearance measuring systems
Button ProbesButton-type capacitive probes
Threaded ProbesThreaded capacitive probes

Where is Capacitec equipment used?

  • Aerospace — blade-to-casing clearance, rotor eccentricity
  • Power generation — measuring turbine clearances
  • Coating and extrusion — die slot control
  • Semiconductors — parallelism and positioning of wafer holders
  • Automotive testing — brake disc wear

How do we supply Capacitec in Romania?

We can take requests for Capacitec probes, amplifiers, cables and Gapman instruments, according to the installed series and configuration. For a correct quotation you need to tell us the probe and amplifier type, the measuring range, the cable length, the working environment (temperature, vacuum, radiation) and the target material. Supply is to order, usually in 1–4 weeks; custom assemblies or those for extreme environments have longer lead times, stated in the quotation. Availability of these items is checked before the quotation.

Calibration and commissioning of Capacitec systems are outside our offer, and compatibility between probes and amplifiers from different generations is checked from the complete configuration.

Frequently asked questions about Capacitec

What does Capacitec make?

Capacitec, from Ayer, makes non-contact capacitive displacement and distance sensors, Capteura modular amplifiers, Gapman portable instruments for measuring clearances and systems for measuring parallelism and flatness, used in aerospace, energy, coatings and semiconductors.

How do I choose a capacitive probe and an amplifier?

The choice starts from the distance to be measured, the displacement range, the cable length and the working environment (temperature, vacuum, magnetic field). The probe and the amplifier are chosen as an assembly, because calibration is tied to that particular pair.

Do you supply Capacitec products in Romania, and within what lead time?

Yes, Capacitec products are supplied to order, and the lead time is usually 1–4 weeks. For probes for extreme environments, custom assemblies or parallelism systems the lead time may be longer and is confirmed in the quotation.

Can I replace an old Capacitec amplifier with a new Capteura series?

It depends on the generation of the amplifier and the probe. Compatibility with the existing probes is checked on the complete configuration, and fits are confirmed only on that basis. Send us the probe and amplifier series, plus the cable length.

What information do you need for a quotation on a clearance measuring system?

We need the measuring range, the minimum clearance to be reached, the target material (conductor, composite), the environment (temperature, vacuum), the output type required and whether you work with a portable instrument or a fixed-mounted system, with the number of channels.

How do I request a Capacitec quotation?

Send the Capacitec code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: Capacitec, Inc. (manufacturer documentation)