For celduc we quote single-phase, three-phase, DC and four-channel solid state relays (SMQR series), magnetic proximity sensors from the PT, PL, PTI or PXS series and reed relays; items are identified by series and voltage.

Headquarters: Sorbiers, France

Request a quote

Who is celduc and what does it make?

celduc relais is a French maker of solid state relays and magnetic proximity sensors, based in Sorbiers, France. The range has three main families: solid state relays (SSR) and power controllers, magnetic proximity sensors, and reed relays with reed switches. Integrated power electronics solutions and products produced to order are added to these.

The solid state relays cover single-phase outputs (series SO7, SO8, SO9, SK, XK and others), two-phase (SIB, SOB5–SOB9), three-phase (SMB, SMT, SGT, SHT) and four-channel (SCQ, SMQR9). For direct current there are relays up to 1700 V DC and 0–150 A, for batteries, heating resistors and DC motors. There are also power versions with diagnostics (SILD, SOD, SOI) and relays for motor control (SMR, SGR).

The SMQR series combines four independent solid state relays with AC output in a single housing, with four 25 A power elements, switching voltage 24–600 V AC and control 10–30 V DC. It suits resistive loads, for example heating elements in ovens or in plastics injection moulding machines. The magnetic sensors form the series PAA, PB, PC, PD, PH, PL, PMG, PSA, PSS, PT, PTF, PTI and PXS, for presence, speed, level and safety. For a quotation, the series, the switching voltage and the load current matter.

What do we supply from the celduc range?

ProductDescription
Single-phase and two-phase solid state relaysSingle-phase series SO7, SO8, SO9, SK, XK, SU9 and two-phase series SOB5–SOB9, with zero-crossing or random switching. Switching voltages range from 110–120 V AC up to 600 V AC.
Three-phase and motor solid state relaysSeries SMB, SMT, SGT and SHT for three-phase loads, plus SMR and SGR for motor control.
DC solid state relays and SMQRDC relays up to 1700 V DC and 0–150 A, for batteries, heating and DC motors. SMQR series with four channels of 25 A each, 24–600 V AC, with a status LED on each input and spring terminals.
Magnetic sensors and reed relaysMagnetic sensors PT, PL, PTI, PTF, PXS and others, with normally open, normally closed or changeover contact, for presence, speed and level. Reed relays in DIP and SIP housings, reed switches and high-voltage relays.

Why celduc?

  • Single-phase, two-phase, three-phase and DC solid state relays — the same family covers loads from heating resistors to motors
  • SMQR series with four channels in one housing — reduces wiring in panels with several heating zones
  • Diagnostic versions on some power relays (SILD, SOD, SOI) — a load fault can be signalled to the controller
  • Magnetic sensors for presence, speed, level and safety, including ATEX versions — they detect without mechanical contact
  • Reed relays in DIP and SIP housings and reed switches — for small signals, at high component density

Which celduc codes and series are requested most often?

CodeDescription
SO7Single-phase solid state relay
SO8Single-phase solid state relay
SO9Single-phase solid state relay
SOB5Two-phase solid state relay
SMTThree-phase solid state relay
SGTThree-phase solid state relay
SHTThree-phase solid state relay
SMQR9Four-channel solid state relay, AC output
SILDPower solid state relay with diagnostics
SMRSolid state relay for motor control
PTSeries of magnetic proximity sensors
PLSeries of magnetic proximity sensors
PTISeries of magnetic proximity sensors
PXSSeries of magnetic proximity sensors

Where is celduc equipment used?

  • Industrial automation — switching of resistive loads and motors with solid state relays
  • Plastics injection moulding machines — control of heating elements with SMQR relays
  • Ovens and heating equipment — precise switching of resistors with solid state relays
  • Lifts — magnetic sensors for car position and door opening control
  • Equipment with ATEX requirements — magnetic sensors for explosive atmospheres

How do we supply celduc in Romania?

We can quote celduc solid state relays, magnetic proximity sensors and reed relays, as well as relays to replace those already installed. For an accurate quotation, send the series or code on the relay, the voltage and load current, the control voltage, the load type (resistive, inductive, motor) and the mounting method. For sensors we need the series, the housing shape and the contact required. We bring items in to order, usually in 1–4 weeks, and an existing relay or sensor can ship in 24–72 h when the item is in stock, locally or at the supplier. The exact lead time is confirmed in the quotation.

The real current of a solid state relay depends on cooling and on the temperature in the panel, so we set the exact series in the quotation according to the mounting conditions you describe.

Frequently asked questions about celduc

What are the SO7, SMT and PT series in the celduc range?

SO7 is a single-phase solid state relay, SMT a three-phase solid state relay, and PT a series of magnetic proximity sensors. celduc relais makes solid state relays and power controllers, magnetic proximity sensors, reed relays and reed switches, as well as power electronics modules produced to order. The company is based in Sorbiers, France. The same families are found in automation, heating and equipment with magnetic sensors.

How do I choose a celduc solid state relay for a load?

What matters is the load type (resistive, inductive or motor), the switching voltage, the current at the panel temperature and the control voltage. The series is then chosen among the single-phase, three-phase or DC ones. With these data we check the suitable series.

Do you supply celduc relays in Romania, and how quickly?

Yes. celduc relays and sensors are brought in to order, usually in 1–4 weeks. A relay or sensor can ship in 24–72 h when the item is in stock, locally or at the supplier. For special series the lead time may be longer and is confirmed in the quotation.

Can I replace an existing celduc relay?

Yes, if we can read the code on the relay. We need the full series (for example SO8 or SMQR), the rated voltage and current, the control voltage and the housing dimensions. We check the current version of the series and the mounting compatibility before the quotation.

How do I specify a request for a PT or PXS series magnetic sensor?

For a PT or PXS series sensor, send the series or code on the sensor, the housing shape (threaded, tubular, for printed circuit), the contact type (normally open, normally closed or changeover), the maximum switching voltage and current and, if applicable, the ATEX requirement. Add the required operating distance.

How do I request a celduc quotation?

Send the celduc code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: celduc relais (manufacturer documentation)