Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Danfoss Danfoss VLT® AutomationDrive FC 302

Danfoss VLT® AutomationDrive FC 302 frequency converters for three-phase supply 200–690 V, from 0.25 kW (at 200–240 V) to 710 kW, with Safe Torque Off as standard and 0–590 Hz output.

FC 302 is part of the VLT® AutomationDrive FC 301/302 range, frequency converters for controlling the speed of motors on industrial machines and production lines. It controls asynchronous motors, permanent magnet motors (SPM and IPM), synchronous reluctance motors (SynRM) and PMaSynRM. It covers three-phase networks of 200–240 V, 380–500 V, 525–600 V and 525–690 V, with an output frequency of 0–590 Hz. Safe Torque Off (STO) and Safe Stop SS1 are included as standard, and the SLS, SMS and SSM functions, the fieldbuses and the encoder interfaces are added through plug-and-play options. The converter has integrated condition-based monitoring (CBM, without PLC and without a cloud connection) and the integrated motion controller (IMC) for positioning and synchronisation. Compared with FC 301 from the same family, FC 302 has more inputs and outputs (6 digital inputs, 2 pulse/encoder inputs, 2 relays), analogue inputs of −10…+10 V and a longer motor cable, of up to 150 m screened.

The type code is read by position; for example, in a code composed according to the Danfoss order key, FC-302P7K5T5E20H1, “302” is the application, “P7K5” the 7.5 kW power, “T5” the 3 × 380–500 V AC network, “E20” the IP20 enclosure, and “H1” the RFI filter class A1/B (C1); these are followed by the brake and safety, the LCP panel, the board coating, the network options, the hardware options, the software version, the panel language and options A, B, C and D. For a quotation, send us the full type code from the converter nameplate; if you do not have it, the motor power and current, the mains voltage, the protection rating required and the options needed (fieldbus, encoder, brake). When the item is in stock, locally or at the supplier, delivery takes 24–72 h; to order, typically 1–4 weeks.

Models and codes

CodeNote
FC-302PK37T50.37 kW, 3 × 380–500 V; 1.3 A continuous (380–440 V); enclosure A2 (IP20/IP21) or A4/A5 (IP55/IP66) — the start of the type code.
FC-302P1K5T51.5 kW, 3 × 380–500 V; 4.1 A continuous, 6.6 A intermittent (60 s); enclosure A2 or A4/A5.
FC-302P4K0T54 kW, 3 × 380–500 V; 10 A continuous (380–440 V); enclosure A2 or A4/A5.
FC-302P7K5T57.5 kW, 3 × 380–500 V; 16 A continuous, 25.6 A intermittent (60 s); enclosure A3 (IP20/IP21) or A5 (IP55/IP66).
FC-302P15KT515 kW at high overload (160 %), 18.5 kW at normal overload (110 %); 32 A continuous at high overload (37.5 A at normal overload); enclosure B3 (IP20) or B1 (IP21/IP55/IP66).
FC-302P37KT537 kW at high overload, 45 kW at normal overload; 73 A continuous at high overload (90 A at normal overload); enclosure C3 (IP20) or C1 (IP21/IP55/IP66).
FC-302P75KT575 kW at high overload, 90 kW at normal overload; 147 A continuous (high overload); enclosure C4 (IP20) or C2 (IP21/IP55/IP66).

Key specifications

Power0.25–150 kW (3 × 200–240 V); 0.37–500 kW (3 × 380–480/500 V); 0.75–75 kW (3 × 525–600 V); 1.1–710 kW (3 × 525–690 V)
Supply voltage3 × 200–240 V, 380–500 V, 525–600 V, 525–690 V, ±10 %, 50/60 Hz
Output frequency0–590 Hz
Overload160 % for 1 min in 10 min (high overload) or 110 % (normal overload)
Protection ratingIP00, IP20, IP21, IP54, IP55, IP66, depending on model
Safety functionsSTO and SS1 as standard; SLS, SMS, SSM through options
Basic inputs/outputs6 digital inputs (2 configurable as outputs), 2 analogue inputs −10…+10 V or 0/4–20 mA, 2 pulse/encoder inputs, 1 analogue output 0/4–20 mA, 2 relays
Motor cable length150 m ecranat / 300 m neecranat
Ambient temperatureup to 50 °C without power reduction

The Danfoss data sheet “VLT® AutomationDrive FC 301/302” (AM444854290489en-020202, July 2026) is published on the official document server assets.danfoss.com, together with the selection guide AD444858538496en-010201 (November 2024).

Frequently asked questions

What is the difference between FC 301 and FC 302?

Both are part of the VLT® AutomationDrive range. FC 301 is supplied at 3 × 200–240 V or 3 × 380–480 V, while FC 302 also covers 525–600 V and 525–690 V and much higher powers. FC 302 also has more inputs and outputs (2 pulse/encoder inputs and 2 relays, versus 1 and 1), analogue inputs of −10…+10 V and a motor cable of up to 150 m screened, versus 50 m.

What do high overload and normal overload mean?

The same power code has two ratings: at high overload (160 % for 1 minute in 10 minutes) and at normal overload (110 %). For example, FC-302P75KT5 is given for 75 kW at high overload and 90 kW at normal overload.

Can FC 302 control a permanent magnet motor?

Yes. The converter controls asynchronous motors, permanent magnet motors (SPM and IPM), synchronous reluctance motors (SynRM) and PMaSynRM.

Other Danfoss series

The currents and enclosures given are taken from the tables of the selection guide for enclosures A, B and C (up to 75/90 kW); for higher powers (enclosures D, E and F) and for the exact combination of options, we confirm the data from the Danfoss documentation for the full type code, before the quotation.

Updated: 2026-11-23