Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Ebara Ebara 3D

Ebara 3D centrifugal pumps standardised to EN 733, with cast iron casing and stainless steel impeller (AISI 304 on sizes 32, 40 and 50, AISI 316 on 65), 2-pole motor of 1.1–22 kW (single-phase only 1.1–2.2 kW), for clean water up to 10 bar and from −5 to +90 °C with the standard seal (up to +110 °C with the H, HS, HW, HSW seals and up to +120 °C with E).

The EBARA 3D series is a centrifugal pump standardised to EN 733, with a cast iron casing (EN-GJL-250), axial suction and radial discharge, with a "back pull-out" design that allows the motor, coupling, support and impeller to be removed without disconnecting the pump casing from the piping. The impeller is in stainless steel: AISI 304 on sizes 32, 40 and 50 and investment-cast AISI 316 on size 65. The EBARA series page presents it in three versions: 3D (close-coupled, with extended shaft), 3DS (rigid coupling and standard IEC motor) and 3DP (flexible coupling and standard IEC motor). The range in the 2-pole Data Book covers sizes 32-125 to 65-200, with a three-phase motor of 1.1–22 kW (single-phase of 1.1–2.2 kW only on the 3D version), for clean water, at a maximum working pressure of 1 MPa (10 bar).

The type key is read by position, following the example in the Data Book: in "3D S H 65-200/22 M U3U3EGG", "3D" is the series, "S" the version (S for the version coupled directly to the standard motor, with rigid coupling; P for the version with its own bearings and flexible coupling; on the 3D without this letter), "H" the optional seal (H, HS, HW, HSW or E), "65" the discharge diameter (32, 40, 50 or 65), "200" the impeller code (125, 160 or 200), "22" the power code in kW, "M" the single-phase motor (without M, the motor is three-phase), and "U3U3EGG" a special seal. Thus, in frequently requested codes, 3D 40-160/4.0 is the pump with discharge 40, impeller code 160 (166 mm impeller) and a 4.0 kW motor, while 3D 40-125/1.5 has discharge 40, impeller code 125 (125 mm impeller) and a 1.5 kW motor. For a quotation, send us the full code from the pump's nameplate or, if it is missing, the required flow and head, the liquid, the temperature and the supply voltage. When the item is in stock, locally or at the supplier, delivery takes 24–72 h; to order, typically 1–4 weeks.

Models and codes

CodeNote
3D 32-125/1.11.1 kW, three-phase (also available single-phase, 3D 32-125/1.1 M); 23 m at zero flow and 12.5 m at 20 m³/h; 133 mm impeller; DN50/DN32 flanges.
3D 40-125/1.51.5 kW, three-phase (also available single-phase, 3D 40-125/1.5 M); 19 m at zero flow and 14.8 m at 24 m³/h; 125 mm impeller; DN65/DN40 flanges.
3D 40-160/3.03.0 kW, three-phase; 31 m at zero flow and 25.8 m at 24 m³/h; 151 mm impeller; DN65/DN40 flanges.
3D 40-160/4.04.0 kW, three-phase; 38.8 m at zero flow and 33.8 m at 24 m³/h (27 m at 42 m³/h); 166 mm impeller; DN65/DN40 flanges.
3D 50-200/1515 kW, three-phase; 71 m at zero flow and 56 m at 72 m³/h; 224 mm impeller, with reinforced laser welding; DN65/DN50 flanges.
3D 65-125/4.04.0 kW, three-phase; 22 m at zero flow and 6 m at 114 m³/h; 128 mm investment-cast AISI 316 impeller; DN80/DN65 flanges.
3D 65-200/2222 kW, three-phase; 68 m at zero flow and 42.5 m at 138 m³/h; 212 mm investment-cast AISI 316 impeller; DN80/DN65 flanges.

Key specifications

Motor power1.1–22 (three-phase); 1.1–2.2 (single-phase, only on the 3D version) kW
Sizes in the selection table (2-pole, 50 Hz)31 types, from 32-125/1.1 to 65-200/22
Flow in the selection table0–138 m³/h
Head at zero flow19 (3D 40-125/1.5) – 71 (3D 40-200/11 and 3D 50-200/15) m
Maximum working pressure1 MPa (10 bar)
Liquid temperature−5 … +90 °C with the standard seal; −5 … +110 °C with H, HS, HW, HSW (for water with FPM elastomers a maximum of 75 °C is recommended); −5 … +120 °C with E and with the special seals
Materialscast iron casing EN-GJL-250; casing cover EN 1.4301 (AISI 304); impeller AISI 304 on sizes 32, 40, 50 and investment-cast AISI 316 on 65; shaft AISI 304 (wet extension); standard seal ceramic/carbon/NBR
ConnectionsEN 1092-2 flanges: suction DN50, DN65 or DN80, discharge DN32, DN40, DN50 or DN65, depending on size
Motor (2-pole version)2-pole, approx. 2,900 rpm, IP 55, insulation class F, 50 Hz; 230 V ±10 % single-phase; 230/400 V ±10 % up to 4 kW and 400/690 V ±10 % from 5.5 kW (three-phase); overload protection is provided by the user

The data come from the "3D SERIES" Data Book 50 Hz, Rev.W (PDF file created on 11.06.2026, 53 pages), published on the 3D(4) series page of the EBARA Pumps Europe website, which lists it among the technical documents of the series; the series is current. The 4-pole version has a separate Data Book (Rev. M).

Frequently asked questions

How do I read a type code such as 3D 40-160/4.0?

The Data Book breaks the code down by position: the series "3D", then (optionally) the version letter S or P, then the optional seal H, HS, HW, HSW or E, the discharge diameter (32, 40, 50 or 65), the impeller code (125, 160 or 200), the power code in kW, "M" for a single-phase motor and, at the end, the code of a special seal. Accordingly, 3D 40-160/4.0 has discharge 40, impeller code 160 (166 mm impeller) and a 4.0 kW motor, while 3D 40-125/1.5 has discharge 40, impeller code 125 (125 mm impeller) and a 1.5 kW motor.

What distinguishes the 3D from the 3DS and 3DP?

The 3D is close-coupled, with extended shaft; the 3DS has a rigid coupling and a standard IEC motor; the 3DP has a flexible coupling and a standard IEC motor. The single-phase motor is available only on the 3D (1.1–2.2 kW). For 4 poles (approx. 1,400 rpm, three-phase, 0.25–3 kW) EBARA publishes a separate Data Book, "3D SERIES 4 Poles"; the models and values listed are those of the 2-pole version.

Which seal do I choose for hot water?

The standard seal (ceramic/carbon/NBR) works between −5 and +90 °C; the H, HS, HW and HSW versions (with FPM elastomers) between −5 and +110 °C, and E (EPDM) and the special seals U3U3EGG, U3CEGG, Q1Q1EGG, Q1U3EGG and Q1AEGG between −5 and +120 °C. For water with FPM elastomers, the Data Book recommends a maximum of 75 °C, for a longer seal life. The pump should not be used below 10 % of the flow at the maximum efficiency point, to avoid overheating.

Other Ebara series

The duty point is chosen from the curves in the EBARA Data Book for the exact code; we confirm the version (3D, 3DS or 3DP), the number of poles, the seal, the impeller material and the motor voltage (single-phase or three-phase) before quotation.

Updated: 2026-11-23