Ebara Ebara 3M
Ebara 3M close-coupled centrifugal pumps in AISI 304 stainless steel, with a 1.1–22 kW motor (single-phase only 1.1–2.2 kW), for clean water and moderately aggressive fluids, up to 10 bar and +90 °C with the standard seal (up to +120 °C with the E seal or the special seals).
The 3M is the close-coupled version of the EBARA 3 series, alongside the 3S (rigid coupling) and 3P (flexible coupling); the EBARA series page describes it as a centrifugal pump conforming to EN 733, with a "back pull-out" design that allows the rotor–motor assembly to be removed without disconnecting the pump casing from the piping. On the 3M, the casing, casing cover and wet part of the shaft are in EN 1.4301 (AISI 304) stainless steel; the impeller is in AISI 304 on sizes 32, 40 and 50 and in cast stainless steel CF8M (EN 1.4408) on size 65. The range covers sizes 32-125 to 65-200, with EN 1092-1 flanges, for clean water and moderately aggressive fluids, at a maximum working pressure of 1 MPa (10 bar). The motor is 2-pole (2,900 rpm), IP 55 protection and insulation class F: three-phase IE3 of 1.1–22 kW or single-phase 230 V IE2 of 1.1–2.2 kW.
The code is read by position: in 3MHS 50-200/11, "3" is the series, "M" the close-coupled version, "HS" the optional seal (H, HS, HW, HSW or E), "50" the nominal discharge diameter, "200" the impeller code, and "11" the power code; an "R" after the power marks the reduced impeller, a final "M" the single-phase motor, and special seals are added at the end (for example Q1AEGG). The version with "L" (3LM) is in AISI 316L. For a quotation, send us the full code from the pump's nameplate or, if it is missing, the required flow and head, the liquid, the temperature and the supply voltage. When the item is in stock, locally or at the supplier, delivery takes 24–72 h; to order, typically 1–4 weeks.
Models and codes
| Code | Note |
|---|---|
| 3M 32-125/1.1 | Three-phase 1.1 kW (also available single-phase, 3M 32-125/1.1 M); 22.5 m at zero flow and 12 m at 20 m³/h; 133 mm impeller; DN50/DN32 flanges. |
| 3M 40-160/3.0 | Three-phase 3 kW; 31 m at zero flow and 17 m at 42 m³/h; 151 mm impeller. |
| 3M 40-200/11 | Three-phase 11 kW; 72 m at zero flow and 59 m at 42 m³/h; 224 mm impeller; 69.6 kg. |
| 3M 50-125/2.2 M | Single-phase 230 V, 2.2 kW (IE2), 12.3 A at rated load, 55 µF capacitor; 19 m at zero flow and 8 m at 60 m³/h. |
| 3M 50-200/11 | Three-phase 11 kW; 59 m at zero flow and 42 m at 72 m³/h; 200 mm impeller; 69.6 kg. |
| 3M 65-160/11 | Three-phase 11 kW; 40.5 m at zero flow and 20 m at 138 m³/h; CF8M 168 mm impeller; 67.4 kg. |
| 3M 65-200/22 | Three-phase 22 kW; 67 m at zero flow and 45 m at 138 m³/h; 212 mm impeller; 136.1 kg. |
Key specifications
| Motor power | 1.1–22 (three-phase, IE3); 1.1–2.2 (single-phase, IE2, only on 32-125, 32-160, 40-125 and 50-125) kW |
|---|---|
| Flow in the selection table | 0–138 m³/h |
| Head at zero flow | 19 (3M 50-125/2.2) – 72 (3M 40-200/11 and 3M 50-200/15) m |
| Maximum working pressure | 1 MPa (10 bar) |
| Liquid temperature | −10…+90 (standard seal); −10…+110 with H, HS, HW, HSW; −20…+120 with E; −10…+120 with the special seals °C |
| Hydraulic materials | casing, cover and shaft (wet end) in EN 1.4301 (AISI 304); impeller AISI 304 on sizes 32–50, CF8M (EN 1.4408) on size 65 |
| Connections | EN 1092-1 flanges: suction DN50 (size 32), DN65 (40 and 50), DN80 (65); discharge DN32–DN65, depending on size |
| Motor | 2-pole, 2,900 rpm, IP 55, class F, 50 Hz; 230 V ±10 % single-phase; 230/400 V ±10 % up to 4 kW, 400/690 V ±10 % from 5.5 kW; overload protection is provided by the user |
| MEI (3M) | ≥ 0.4 (32-125, 50-125); ≥ 0.6 (32-200); ≥ 0.7 (the other sizes) |
The data come from the "3 SERIES" Data Book 50 Hz, Rev.AM (PDF file created on 25.09.2026, 97 pages), published on the 3(L)(4) series page of the EBARA Pumps Europe website; the document covers the 3M, 3S and 3P versions together; the data given are those of the close-coupled 3M version. The series is current.
Frequently asked questions
What do 3M, 3ME, 3MHS and 3LM mean?
"M" marks the close-coupled version of the 3 series (S and P are the versions with rigid and flexible coupling respectively). The letters after M show the optional seal: E has an EPDM elastomer, HS silicon carbide rings and an FPM elastomer, while H, HW and HSW are other material combinations. "L" before M (3LM) means the version in AISI 316L. We confirm designations that do not appear in the current type key, for example "/I", from the pump's nameplate.
Which seal do I choose for hot water or drinking water?
The standard seal (carbon/ceramic/NBR) works between −10 and +90 °C, the H, HS, HW and HSW versions up to +110 °C, and E and the special seals up to +120 °C; with water and FPM elastomers a maximum of 75 °C is recommended, for a longer seal life. For drinking water, the documentation indicates WRAS approval for the 3ME (EPDM version) on sizes 32, 40, 50 and 65 and DM174/2004 (ICIM) approval for the E versions on sizes 32, 40 and 50.
Can 3M pumps work at very low flows?
No: to avoid overheating, the pump should not be used below 10 % of the flow at the maximum efficiency point. The curves in the Data Book, measured with clean water at 20 °C, with tolerances according to ISO 9906:2012 grade 3B, show the recommended working range with a solid line.
Other Ebara series
The duty point is chosen from the curves in the EBARA Data Book for the exact code; we confirm the seal, the impeller material and the motor voltage (single-phase or three-phase) before quotation.
Updated: 2026-11-23