Ebara Ebara DWC
Ebara DWC centrifugal pumps with closed impeller and AISI 304 stainless steel hydraulics, three-phase 1.1–3 kW, with Victaulic or G 2 threaded connection, for moderately aggressive liquids, glycol solutions and washing installations, from −15 °C to +120 °C.
The DWC is the Ebara centrifugal pump with a single closed impeller, with the casing, impeller, casing cover and shaft (wet end) in EN 1.4301 (AISI 304) stainless steel, with an aluminium motor support and a standard ceramic/carbon/EPDM mechanical seal. The documentation describes it for moderately aggressive liquids, glycol solutions, liquids with impurities and liquids for industrial washing equipment, not for clean water; the maximum working pressure is 0.8 MPa (8 bar). It is supplied with a Victaulic Ø 2″ (60.3 mm) connection, the DWC-V version, or with a G 2 thread, the DWC-N version. The motor is three-phase, enclosed and fan-cooled, 2-pole (2,800 rpm), insulation class F, IP 55 protection and IE3 efficiency, for 230/400 V ±10 %; overload protection is provided by the user.
The code is read by position: in DWC H-V 500/3.0 Q1AVGG, "H" marks the optional seal (H, HS, HW or HSW), "V" the Victaulic connection (N for the threaded one), "500" the hydraulic series (300 or 500), "3.0" the power in kW, and the last group the special seal. For a quotation, send us the full code from the pump's nameplate or, if it is missing, the required flow and head, the liquid and its temperature, the type of connection and the supply voltage. When the item is in stock, locally or at the supplier, delivery takes 24–72 h; to order, typically 1–4 weeks.
Models and codes
| Code | Note |
|---|---|
| DWC 300/1,1 | 1.1 kW (IE3); 21.0 m at zero flow and 8.5 m at 24 m³/h; 133 mm impeller. |
| DWC 300/1,5 | 1.5 kW; 24.5 m at zero flow and 12.0 m at 24 m³/h; 148 mm impeller. |
| DWC 500/1,5 | 1.5 kW; 18.5 m at zero flow and 6.2 m at 45 m³/h; 125 mm impeller. |
| DWC 500/2,2 | 2.2 kW; 24.5 m at zero flow and 11.5 m at 45 m³/h; 140 mm impeller. |
| DWC 500/3,0 | 3 kW (4 HP); 26.3 m at zero flow and 13.6 m at 45 m³/h; 148 mm impeller. |
Key specifications
| Motor power | 1.1–3 (three-phase, IE3) kW |
|---|---|
| Flow in the selection table | 0–45 (DWC 300 up to 24) m³/h |
| Head at zero flow | 18.5 (DWC 500/1,5) – 26.3 (DWC 500/3,0) m |
| Maximum working pressure | 0.8 MPa (8 bar) |
| Liquid temperature | −15…+120 (standard seal); −15…+110 with H, HS, HW, HSW and Q1AVGG; −15…+120 with AQ1EGG, VAEGG, Q1U3EGG, U3BEGG °C |
| Materials | casing, impeller, cover and shaft (wet end) in AISI 304 (EN 1.4301); aluminium motor support |
| Connections | DWC-V: Victaulic Ø 2″ (60.3 mm); DWC-N: G 2 |
| Motor | 2-pole, 2,800 rpm, IP 55, class F; 230/400 V ±10 %, 50 Hz |
| Noise (LpA at 1 m) | below 70 (tolerance ±2.5) dB(A) |
Data Book DWC 50 Hz, Rev. K (colophon 04/24), is one of the technical documents published on the DWC series page of the Ebara Pumps Europe website; the series is current.
Frequently asked questions
What do V and N mean in the DWC code?
V marks the Victaulic Ø 2″ (60.3 mm) connection, N the G 2 threaded connection; suction and discharge have the same type of connection. The pump weighs 15.4–22.3 kg, depending on the model.
Which seal do I choose for high temperatures?
The standard seal (ceramic/carbon/EPDM) works between −15 and +120 °C, the H, HS, HW and HSW versions between −15 and +110 °C, and the special seals AQ1EGG, VAEGG, Q1U3EGG and U3BEGG between −15 and +120 °C (Q1AVGG: up to +110 °C). For water with FPM elastomers, a maximum of 75 °C is recommended, for a longer seal life.
Can the DWC work with clean water?
The Ebara documentation indicates the DWC for moderately aggressive liquids, glycol solutions, liquids with impurities and liquids for industrial washing equipment, and states that the pump is not suitable for clean water. For other industrial liquids we confirm compatibility on the exact code. The pump should not be used below 10 % of the flow at the maximum efficiency point.
Other Ebara series
The duty point is chosen from the performance curves in the Ebara documentation for the exact code; we confirm the liquid, the temperature, the seal, the type of connection and the motor voltage before quotation.