Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Ebara Ebara EVMS (EVMSL, EVMSG)

Ebara EVMS vertical multistage centrifugal pumps in AISI 304 stainless steel, EVMSL in AISI 316L and EVMSG with a cast iron base, with nominal flows of 1–90 m³/h, up to 35 bar and −30…+140 °C.

The EVMS is the Ebara vertical multistage centrifugal pump, non-self-priming, with in-line suction and discharge, in ten sizes by nominal flow: 1, 3, 5, 10, 15, 20, 32, 45, 64 and 90 m³/h. The impellers, intermediate chambers and outer sleeve are in AISI 304 on the EVMS and EVMSG (the EVMSG has a cast iron lower casing and base), and in AISI 316L on the EVMSL. The maximum working pressure is 16 or 25 bar on sizes 1–20 and up to 35 bar on sizes 32–90, and the liquid can be at −30…+140 °C; the ranges −30…−15 °C and +120…+140 °C are assessed separately for each application. The reduced axial thrust allows standard IEC motors to be coupled (IM B14 up to 4 kW, IM B5 from 5.5 kW); Ebara motors are 2-pole, IE3 above 0.75 kW and have a PTC sensor from 1.5 kW. The cartridge-type mechanical seal (EN 12756) is replaced without removing the motor support.

The code is read by position: in EVMS5 2F5Q1BEG E/0.37M, "EVMS" is the series (EVMSL = AISI 316L, EVMSG = cast iron), "5" the nominal flow in m³/h, "2" the number of impellers, "F" the round flange (N = oval, LF = loose flange, V = Victaulic, C = clamp), "5" the 50 Hz frequency, "Q1BEG" the seal, "E" the EPDM elastomers (V = FPM), "0.37" the motor power in kW, and "M" the single-phase motor. On sizes 32–90, a code such as EVMS45 1-1F5BQ1EG E/3.0 also indicates the number of reduced-diameter impellers. For a quotation, send us the full code (TYPE) and the article number (P/N°) from the nameplate or, if they are missing, the flow, the head, the liquid, the temperature and the pressure in the installation. When the item is in stock, locally or at the supplier, delivery takes 24–72 h; to order, typically 1–4 weeks.

Models and codes

CodeNote
EVMS1 10/0.550.55 kW, single-phase or three-phase; 59.6 m at zero flow; 1.6 MPa.
EVMS3 12/1.11.1 kW, single-phase or three-phase; 88.5 m at zero flow; 1.6 MPa.
EVMS5 10/2.22.2 kW, single-phase or three-phase; 95 m at zero flow; 1.6 MPa.
EVMS10 5/2.22.2 kW, single-phase or three-phase; 54.5 m at zero flow; 1.6 MPa.
EVMS15 4/4.0Three-phase 4.0 kW; 59 m at zero flow; 1.6 MPa.
EVMS20 6/7.5Three-phase 7.5 kW; 101 m at zero flow; 1.6 MPa.
EVMS45 6-0/22Three-phase 22 kW; 162 m at zero flow; 2.5 MPa.
EVMS45 10-2/37Three-phase 37 kW; 269 m at zero flow; 3.5 MPa.

Key specifications

Nominal flow1, 3, 5, 10, 15, 20, 32, 45, 64, 90 m³/h
Head at zero flow11.9 (EVMS1 2/0.37) – 342 (EVMS45 13-2/45) m
Motor power0.37–45 (three-phase); 0.37–2.2 (single-phase) kW
Maximum working pressure16 / 25 bar (sizes 1–20); 16 / 25 / 30 / 35 bar (sizes 32–90)
Liquid temperature−30…+140 °C
Hydraulic materialsAISI 304 (EVMS); AISI 316L (EVMSL); AISI 304 with cast iron lower casing and base (EVMSG)
Sealcartridge-type mechanical, EN 12756; unbalanced up to 16 bar, balanced up to 25 bar (35 bar on sizes 32–90)
Motor2-pole, IE3 above 0.75 kW; IP55 up to 11 kW, IP56 above 15 kW; class F
Connectionsoval, round or loose flange, Victaulic, clamp (1–20); round or loose flange (32–90)

Data Book EVMS 1-90 50 Hz, Rev. H (file updated in April 2025), is one of the technical documents published on the EVMS(L)(G) series page of the Ebara Pumps Europe website; the series is current.

Frequently asked questions

What is the difference between EVMS, EVMSL and EVMSG?

The EVMS has the impellers, intermediate chambers and outer sleeve in AISI 304 stainless steel, the EVMSL the same parts in AISI 316L, and the EVMSG has AISI 304 hydraulics with a cast iron lower casing and base. All three have the same nominal flow sizes, from 1 to 90 m³/h.

Can I fit a standard IEC motor to an EVMS pump?

Yes. The impellers reduce the axial thrust, so standard IEC motors can be coupled on all models, without reinforced thrust bearings: IM B14 flange up to 4 kW and IM B5 from 5.5 kW. The spacer coupling allows maintenance without removing motors above 5.5 kW.

Which seal do I choose for hot water?

Balanced seals with EPDM elastomers (HQ1BEG, HQgQ1EG) work at −30…+140 °C, up to 25 bar (35 bar on sizes 32–90); Q1BEG and BQ1EG work up to +120 °C and 16 bar, and the FPM versions up to +80 °C.

Other Ebara series

The duty point, the number of impellers and the seal are chosen from the curves in the Ebara documentation for the exact code; we confirm the maximum pressure and the temperature for the given application before quotation.

Updated: 2026-11-23