Edwards Vacuum supplier in Romania

For Edwards we quote iXM, iXH and iXL dry pumps for semiconductors, mXDS and nXDS scroll pumps, nEXT turbomolecular pumps and RV and nES rotary vane pumps; for a quotation we use the full code from the nameplate.

Founded in 1919 · Headquarters: Burgess Hill, United Kingdom

Request a quote

Who is Edwards Vacuum and what does it make?

Edwards Vacuum is a British manufacturer of vacuum pumps and exhaust gas abatement systems, founded in 1919 in London and now headquartered in Burgess Hill. Technical vacuum appears wherever a process requires pressure below atmospheric: semiconductor production, research laboratories, power generation, metallurgy, freeze-drying or space simulation.

The programme starts with dry pumps for semiconductors in the iXM, iXH and iXL series, passes through the mXDS, nXDS and XDS scroll pumps, with no oil in the pumping chamber, and reaches the nEXT mechanical turbomolecular pumps, offered in sizes of 55, 85, 240, 300, 400, 730, 925 and 1250 l/s for nitrogen. Alongside are oil-sealed rotary vane pumps: the two-stage RV series, with speeds of 3–12 m³/h, and the single-stage nES series. nXDS pumps run between 6 and 20 m³/h, with a noise level of 52 dB(A) and service intervals of up to five years.

In maintenance, the usual interest is roughing pumps for existing installations and turbopumps in laboratories and analysis lines. For a quotation we use the full nameplate code (for example RV8 or nXDS6i), the supply voltage and, for turbomolecular pumps, the inlet flange. For maintenance there are vacuum pump oils and parts kits.

What do we supply from the Edwards Vacuum range?

ProductDescription
iXM, iXH, iXLDry pumps for semiconductors. iXM saves energy and resists corrosion better, iXH is for severe processes with deposits, and iXL covers light duties such as wafer handling, PVD and metrology, with compact sizes and low noise.
mXDS, nXDS and XDSDry scroll pumps, with no oil to change or dispose of. mXDS3 has 3 m³/h and an ultimate vacuum of 0.1 mbar, while nXDS runs between 6 and 20 m³/h, with manual controls and speed-control functions in standby mode.
nEXTMechanical turbopumps with hybrid bearings and an integrated controller. The series includes the compact nEXT55 and nEXT85, nEXT240, nEXT300 and nEXT400 for research and analysis, and nEXT730, nEXT930 and nEXT1230 for high flow rates and harsh industrial applications.
RV and nESOil-sealed rotary vane pumps for roughing vacuum. RV has two stages and the robustness for continuous production, nES is the single-stage version; both have gas ballast for water vapour.

Why Edwards Vacuum?

  • nXDS scroll pumps without oil and with service intervals of up to five years — suitable where oil would contaminate the process
  • nEXT turbomolecular pumps in eight sizes, from 55 to 1250 l/s for nitrogen — from analysis to industrial processes
  • iXM series with an energy-efficient Roots mechanism — dry pumps for etching and other processes with powders
  • RV series two-stage rotary vane pumps — a robust roughing pump, 3–12 m³/h
  • Compact, quiet iXL versions for wafer handling and light-duty measurements

Which Edwards Vacuum codes and series are requested most often?

CodeDescription
iXMLow-energy dry pumps for semiconductors
iXH / iXH Mk2Dry pumps for severe processes
iXL600 / iXL1000Compact dry pumps for light duty
iXL900RLoad-lock pump for flat panel display (FPD) applications
mXDS3Dry scroll, 3 m³/h
nXDS6iDry scroll, nXDS family 6–20 m³/h
nEXT55 / nEXT85Compact turbopumps, 55 and 85 l/s
nEXT240 / 300 / 400Turbopumps for research, UHV and analysis
nEXT730 / 930 / 1230High-capacity turbopumps
RV8Two-stage rotary vane pump
nES65 / nES100Single-stage rotary vane pumps

Where is Edwards Vacuum equipment used?

  • Semiconductors and electronics — dry pumps for etching, PVD and deposition
  • Laboratories and analysis — turbopumps for mass spectrometry and microscopy
  • Energy and research — vacuum for accelerators and experimental installations
  • Metallurgy and vacuum coatings — roughing and Roots pumps
  • Pharmaceutical and food industry — freeze-drying with oil-free scroll pumps

How do we supply Edwards Vacuum in Romania?

You can request Edwards vacuum pumps from the RV, nES, nXDS, mXDS and nEXT series from us, based on the full nameplate code. Parts and pumps are supplied to order, usually 1–4 weeks; the lead time is 24–72 h when the item is in stock, locally or at the supplier. Dry pumps for semiconductors are configured systems, so the lead time may be longer. It helps us to receive the voltage and frequency, pumping speed, required ultimate vacuum, pumped gas and inlet flange.

Factory repairs and abatement of exhaust gases from semiconductor fabs are outside our offer, and some configurations for process lines are confirmed with the technical datasheet of the installation.

Frequently asked questions about Edwards Vacuum

What types of vacuum pumps does Edwards make?

Edwards makes dry pumps for semiconductors (iXM, iXH, iXL), dry scroll pumps (mXDS, nXDS, XDS), nEXT mechanical turbopumps and oil-sealed rotary vane pumps, namely the RV and nES series. They are equipment for roughing vacuum, high vacuum and process lines.

How do I size the turbopump and the roughing pump?

The turbopump works in the molecular regime and needs a suitable roughing pump, for example an nXDS or a diaphragm pump. Start from the required pumping speed, the ultimate vacuum and the pumped gas. With these data and the flange in the installation we check the available combinations.

Do you supply Edwards pumps in Romania, and within what lead time?

Yes, Edwards pumps supplied to order reach Romania. For the usual series the lead time is 1–4 weeks, and parts can ship in 24–72 h when the item is in stock, locally or at the supplier. Large process pumps need a longer interval.

Can I replace an old RV pump with a current model?

It depends on the series and the electrical version. Send us the pump nameplate (for example RV8), the voltage, the motor type and the connections. We check whether the current model can fit the same mounting position; equivalence is confirmed on the basis of these data.

What information should a request for nXDS or nEXT contain?

For nXDS we ask for the exact model, the supply voltage and the accessories needed (exhaust filter, valve). For nEXT, state the size, the flange, the controller type and whether the pump works in any orientation. For a parts request, also add the kit code.

How do I request a Edwards Vacuum quotation?

Send the Edwards Vacuum code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.