InstruTech supplier in Romania
Vacuum gauges and vacuum controllers
Founded in 2002 · Headquarters: Longmont, Colorado, USA
Who is InstruTech and what does it make?
InstruTech was founded in 2002 in Longmont, Colorado, near the national metrology institute NIST and the University of Colorado, and designs and manufactures vacuum measurement and control instruments. Its vacuum gauges cover, taken together, pressures from 2×10⁻¹¹ Torr up to 1,000 Torr, through four technologies: convection-enhanced Pirani, Bayard-Alpert hot-cathode ionisation, inverted-magnetron cold-cathode ionisation and capacitance diaphragm. They are used in semiconductors, flat panel displays, solar cells, thin-film deposition, analytical equipment and research, that is, in processes where the pressure has to be read and controlled continuously.
The range is organised by sensor type. In ionisation there are IGM401 (hot cathode, from 10⁻⁹ to 5×10⁻² Torr), CCM502 (cold cathode) and the CC605/CC606 and BA600, BA601/602/603 models; in the Pirani and convection range, CVM201, CVM211, CVG101 and PCM301 (capacitive Pirani, gas-independent above 7.6 Torr). For the wide range there are IGM402 and WGM701, and for precise absolute pressure, CDM900 with a capacitance diaphragm. The controllers are VGC301, AGC302 and multichannel models for rack or panel, with RS232 and RS485 communication.
InstruTech is found on replacement vacuum gauges for vacuum installations and in new laboratory projects. In a replacement, what matters is the flange, the output (analogue or serial), the pressure range, the gas measured and the existing controller. A sensor cannot be swapped on technology alone, because the cables and the electronics differ between families.
What do we supply from the InstruTech range?
| Product | Description |
|---|---|
| Ionisation vacuum gauges (IGM401, CCM502, BA600) | IGM401 and IGM402 are Hornet hot-cathode sensors, with setpoint relays and RS485. CCM502 is the cold-cathode version. The BA600, BA601–603 and CC605/CC606 families cover ranges from 2×10⁻¹¹ to 5×10⁻² Torr. |
| Pirani and convection vacuum gauges (CVM201, CVM211, CVG101, PCM301) | Sensors from 10⁻⁴ to 1,000 Torr, with enhanced convection, and PCM301 with capacitive Pirani from 3.8×10⁻⁵ to 1,125 Torr, with gas-independent measurement above 7.6 Torr. Usual range from medium vacuum up to atmospheric pressure. |
| Diaphragm and full-range vacuum gauges (CDM900, WGM701) | CDM900 is a capacitance diaphragm sensor for absolute pressure from 5×10⁻³ to 1,000 Torr. WGM701 combines cold cathode and Pirani from 7.6×10⁻¹⁰ to 760 Torr. |
| VGC301, AGC302 and rack/panel controllers | VGC301 serves a single CVG101 sensor, AGC302 operates active InstruTech sensors such as WGM701, CCM502, PCM301 or CDM900. The rack or panel models control one ionisation sensor and up to two convection sensors. |
Why InstruTech?
- Four sensor technologies in the same range — convection Pirani, hot-cathode ionisation, cold-cathode ionisation and capacitance diaphragm
- Ranges covered from 2×10⁻¹¹ to 1,000 Torr — composite sensors for the whole interval or dedicated sensors can be chosen
- Combined sensors — IGM402 covers from 10⁻⁹ to 1,000 Torr together with two external convection gauges, and WGM701 combines the cold cathode with Pirani
- Serial communication — RS232 and RS485 on the controllers and setpoint relays on some models, for integration into a PLC
- Controllers for several configurations — from a single channel for active gauges to a multichannel rack with up to three sensors
Which InstruTech codes and series are requested most often?
| Code | Description |
|---|---|
| IGM401 | Hornet hot-cathode sensor, 1×10⁻⁹ to 5×10⁻² Torr |
| IGM402 | Hornet hot-cathode module that controls two external convection gauges; combined range 1×10⁻⁹ to 1,000 Torr |
| CCM502 | Hornet cold-cathode sensor, 7.6×10⁻¹⁰ to 7.6×10⁻³ Torr |
| CC605 / CC606 | Cold-cathode sensors, 7.5×10⁻¹¹ to 3.75×10⁻³ Torr |
| BA600 | Mini IG hot-cathode sensor |
| BA601 / BA602 / BA603 | Bayard-Alpert sensors, bare and glass-envelope types |
| CVM201 | Super Bee convection sensor, 1×10⁻⁴ to 1,000 Torr |
| CVM211 | Stinger convection sensor |
| CVG101 | Worker Bee convection sensor |
| PCM301 | Busy Bee capacitive Pirani sensor, 3.8×10⁻⁵ to 1,125 Torr |
| CDM900 | Micro Bee capacitance diaphragm sensor |
| WGM701 | Wasp cold-cathode and Pirani sensor |
| VGC301 | Single-channel controller for the CVG101 sensor |
| AGC302 | Single-channel controller for active InstruTech sensors |
Where is InstruTech equipment used?
- Semiconductors — pressure monitoring in process chambers
- Thin-film deposition — vacuum gauges for PVD installations
- Flat panels and solar cells — vacuum control on production lines
- Analytical equipment — vacuum gauges on spectrometers and laboratory instruments
- Research — measurement in high and ultra-high vacuum
How do we supply InstruTech in Romania?
We can quote InstruTech vacuum gauges and controllers based on the code on the sensor, for example IGM401, CVM201 or CDM900. Supplied to order, usually in 1–4 weeks for standard models; for configurations with special cables or different flanges the lead time can be longer and is confirmed in the quotation. For a replacement send us the full code, the flange type, the pressure range wanted, the output needed (analogue or RS232/RS485), the gas measured and the model of the controller the sensor connects to.
A sensor is confirmed as a replacement for another manufacturer's model only after analysing the datasheet and the wiring and after a test on the existing controller.
Frequently asked questions about InstruTech
What products does InstruTech make?
InstruTech, founded in 2002 in Colorado, makes vacuum gauges and vacuum controllers: convection Pirani sensors, ionisation sensors (hot or cold cathode) and capacitance diaphragm sensors, plus controllers for one or more sensors, with a total range from 2×10⁻¹¹ to 1,000 Torr.
How do I choose between an ionisation, a Pirani and a capacitance sensor?
Ionisation (for example IGM401 or CCM502) is for high and ultra-high vacuum, convection Pirani (CVM201) for medium vacuum up to atmosphere, and the capacitance diaphragm (CDM900) for gas-independent absolute pressure. Send us the pressure range and the process gas.
Do you supply InstruTech vacuum gauges in Romania and how long does it take?
Yes, supplied to order. Standard models usually take 1–4 weeks; configurations with special cables or flanges can take longer. You receive the exact lead time in the quotation, after the code on the sensor has been checked.
Can I use an InstruTech sensor with my existing controller?
The AGC302 controller, for example, operates the active sensors WGM701, CCM502, PCM301 and CDM900, and is compatible with CVM201, CVM211, CCM501, IGM401 and IGM402. For other controllers the match is confirmed on the basis of the wiring and the datasheet; send the model of the controller.
What data do I need to send for a quotation on a replacement vacuum gauge?
The code on the sensor, the flange type, the pressure range, the output required (analogue or serial), the cable length, the gas measured and the model of the controller. A photo of the nameplate or of the label helps to identify the family exactly.
How do I request a InstruTech quotation?
Send the InstruTech code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: InstruTech, Inc. (manufacturer documentation)