Allectra supplier in Romania
Electrical feedthroughs, valves and windows for vacuum
Founded in 2002 · Headquarters: Berlin, Germany
Who is Allectra and what does it make?
Allectra GmbH was founded in Berlin in 2002 to manufacture and supply electrical feedthroughs for vacuum, and over time has come to produce many types of components for high vacuum (HV) and ultra-high vacuum (UHV). The company has two further production units, one in Sussex, in the United Kingdom, and one in Villingen-Schwenningen, in southern Germany, plus sales offices in several European countries. The range includes Sub-D, coaxial, multipin, high-current and thermocouple feedthroughs, connectors and cables, valves, viewports, motion elements and flange accessories.
The distinctive feature is the large number of parts with a fixed code, in which a feedthrough is chosen by the mounting flange and the connector wanted: for example DN100CF with three 9-pin Sub-D connectors (210-D09-C100-3) or DN40CF with a 15-pin Sub-D connector for thermocouples (210-D15-C40-TCN). There are non-magnetic, titanium or high-current variants. Manual or pneumatic angle valves are offered on CF, KF and ISO-K flanges, and the quartz windows have coatings for wavelengths such as 193, 248 or 780 nm.
Requests usually come from laboratories and research institutes, from manufacturers of equipment with a vacuum chamber and from thin-film deposition lines that need a replacement part or a modification. The flange standard (CF, KF, ISO), the nominal diameter, the number of pins, the voltage, the current and the material must be confirmed when ordering, because a small difference makes the part incompatible with the existing chamber.
What do we supply from the Allectra range?
| Product | Description |
|---|---|
| Sub-D electrical feedthroughs | Vacuum feedthroughs with 9-pin or 15-pin Sub-D connectors, mounted on CF flanges from DN40 to DN100, with non-magnetic, titanium or high-current variants. Models with several connectors on the same flange reduce the number of chamber ports. |
| Thermocouple feedthroughs | 15-pin Sub-D feedthroughs intended for thermocouples (for example 210-D15-C40-TCN), together with crimp pins for Sub-D connectors of type J, K, N and T. Used for temperature measurement in vacuum chambers, furnaces and deposition installations. |
| Angle valves for vacuum | Manual or electropneumatically controlled angle valves, with Viton or bellows sealing, on CF, KF and ISO-K flanges. Bodies in stainless steel or aluminium, with position indicator and 24 V solenoid valve options. |
| Motion elements and windows | Rotary drives with O-ring sealing on KF flanges and precision rotary drives on DN40CF (75 or 100 mm), with stepper motor variants, plus quartz windows for DN40CF and DN63CF with optical coatings. |
Why Allectra?
- Fixed codes by flange and connector — feedthroughs are identified by code, which simplifies reordering a part already installed
- Special vacuum variants — non-magnetic, titanium, high-current and thermocouple versions on the same flange
- Several flange standards — CF, KF and ISO-K for valves and accessories, in sizes such as DN16, DN40 and DN63
- Viewports with optical coatings — quartz with treatment for UV and near-infrared wavelengths
- In-house manufacturing at three locations — Berlin, Sussex and Villingen-Schwenningen, with design of parts to order
Which Allectra codes and series are requested most often?
| Code | Description |
|---|---|
| 210-D09-C100-3 | DN100CF with three 9-pin Sub-D feedthroughs |
| 210-D09-C100 | DN100CF with one 9-pin Sub-D feedthrough |
| 210-D09-C40-HC | DN40CF with 9-pin Sub-D feedthrough for high current |
| 210-D09-C40-TI | DN40CF titanium flange, 9-pin Sub-D feedthrough |
| 210-D15-C40-TCN | DN40CF with 15-pin Sub-D feedthrough for thermocouples |
| 213-PINF-K | Crimp pins for type K thermocouples, 5 pairs |
| 241-ADAPT-BNC-SMA | BNC female to SMA male adapter, for use in air |
| 511-AV-C40-V | Manual angle valve DN40CF, Viton sealing |
| 511-AV-C16-V | Manual angle valve DN16CF, Viton sealing |
| 611-PRD-C40-100 | Precision rotary drive on DN40CF, length 100 mm |
| 611-ORD-K16 | Rotary drive with O-ring sealing on 16 KF flange |
Where is Allectra equipment used?
- Scientific research — vacuum installations for physics and materials science
- Vacuum equipment manufacturers — chambers and process lines, OEM
- Thin-film deposition — installations with HV and UHV chambers
- Semiconductors and optics — windows, feedthroughs and valves for process chambers
- Furnaces and test chambers — feedthroughs for thermocouples and sensors
How do we supply Allectra in Romania?
We can quote Allectra vacuum components based on the part code or its full description. Supply is to order; parts with a fixed code usually take 1–4 weeks, and special designs or large quantities may take longer, with the exact lead time confirmed in the quotation. For a correct quotation send us the code or a photo of the existing part, the flange standard (CF, KF or ISO-K) and the nominal diameter, the number of pins and the connector type, the maximum voltage and current, the material (stainless steel, titanium, non-magnetic version) and the working temperature.
The compatibility of a part with an existing vacuum chamber is established from its exact dimensions, and leak or outgassing values are taken from the datasheet.
Frequently asked questions about Allectra
What products does Allectra make?
Allectra, founded in Berlin in 2002, makes components for high and ultra-high vacuum: electrical feedthroughs (Sub-D, coaxial, multipin, for thermocouples), connectors and cables, valves, windows, motion elements and accessories. It has units in Germany and in the United Kingdom and can make parts to order.
How do I choose an Allectra electrical feedthrough for a vacuum chamber?
Start from the chamber flange (for example DN40CF or DN100CF), then the number of pins and the connector type, to which are added the voltage, the current and the material. Non-magnetic or titanium variants are chosen for applications sensitive to magnetic fields. Send us a photo of the flange and the electrical specifications.
Can you supply Allectra components in Romania, and within what lead time?
Yes. Parts with a fixed code are ordered and usually supplied in 1–4 weeks; special designs may take longer. After checking the part code, we send the quotation with the precise lead time.
Can I replace an old electrical feedthrough with an Allectra code?
Equivalence is checked on the flange standard, the diameter, the number of pins, the connector and the electrical data, not on appearance alone. If the old part has a code or a drawing, send them; without them, the exact dimensions and a photo are useful.
What data should I send for a quotation on vacuum valves and windows?
For valves: the flange standard and size (KF, CF, ISO-K), the type of actuation (manual or pneumatic), the body material and the sealing. For windows: the flange, the glass material and the wavelength range for the optical coating, for example 193, 248 or 780 nm.
How do I request a Allectra quotation?
Send the Allectra code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Allectra GmbH (manufacturer documentation)