DVP supplier in Romania

For DVP we quote rotary vane vacuum pumps from the SC, CC, LC, LX and XC series, PA, VB and CPAP claw pumps, RC and DC high-vacuum pumps, vanes, oils and spare parts kits; the item is identified by pump series and flow rate.

Headquarters: San Pietro in Casale, Italy

Request a quote

Who is DVP and what does it make?

DVP Vacuum Technology is an Italian manufacturer of vacuum pumps and compressors, based in San Pietro in Casale, in the province of Bologna. The programme starts with rotary vane pumps, in dry and oil-lubricated versions, and continues with claw, piston and lobe pumps, blowers, high-vacuum pumps, industrial vacuum systems, accessories, filters and spare parts. The equipment is used in packaging, environmental protection and the chemical industry.

Selection starts from the air being drawn in. The dry pumps of the SC and CC series run without oil in the pumping chamber and do not accept air containing traces of moisture, oil or other liquids; at 50 Hz, the series range from SC 5, at 5 m³/h, up to SC 100 and SC 140, at 100–130 m³/h. The lubricated LC pumps start at LC 2 and LC 4, at 2–4 m³/h, and reach LC 205 and LC 305, at 205–305 m³/h, while the LX 550 and LX 650 series reach 550–650 m³/h. The WR versions have a reinforced gas ballast system, for air that may contain moisture.

The PA, VB, VA and CPAP claw pumps run dry, with no contact between the rotors, and cover flow rates between 155 and 750 m³/h at 50 Hz. For very low ultimate pressures there are the RD, RC, DB and DC high-vacuum pumps, with oil sealing, in one or two stages, used in refrigeration and air conditioning, analytical work, metallurgy and chemistry. Vanes, oils and spare parts kits cover the maintenance of pumps already in service. For an accurate quotation, what matters is the series on the nameplate, the flow rate, the motor voltage and the nature of the gas drawn in.

What do we supply from the DVP range?

ProductDescription
SC, CC, SB and CB dry vacuum pumpsRotary vane pumps with no oil in the pumping chamber, from SC 5 (5 m³/h at 50 Hz) up to SC 140 (130 m³/h). They run continuously at atmospheric pressure and under vacuum, do not accept air containing moisture or liquids, and can also be used as compressors.
LC, LX and XC lubricated vacuum pumpsVane pumps with oil, from LC 2 (2 m³/h at 50 Hz) to LC 305 (305 m³/h), then LX 550 and LX 650 (550–650 m³/h) and XC 405–905 (410–915 m³/h). The WR versions have a reinforced gas ballast for humid air.
PA, VB, VA and CPAP claw pumpsPumps with two claw-shaped rotors that turn in the chamber without contact, synchronised by gears. They include PA 155 and PA 315 (155–250 m³/h at 50 Hz), VB 315 (315 m³/h) and CPAP Duplex and Triplex (310–750 m³/h).
RD, RC, DB and DC high-vacuum pumpsRotary vane pumps with oil sealing, in one or two stages, from RD 2D (1.8 m³/h at 50 Hz) to RC 50M (50 m³/h). The exhaust is not filtered, so exhaust filters are fitted separately, depending on the application.

Why DVP?

  • Dry and lubricated vane pumps in the same production family — selected by the air being drawn in, rather than adapting a pump built for a different duty
  • WR versions with reinforced gas ballast — for air with moisture, where an ordinary lubricated pump degrades its oil
  • Claw pumps that run dry with no contact between the rotors — no lubricant in the pumping chamber, with the timing gears lubricated separately
  • RC and DC high-vacuum pumps, in one or two stages — for refrigeration systems, analytical work and metallurgy, where the ultimate pressure matters
  • Vanes, oils and spare parts kits for existing pumps — an older pump can be brought back to working condition without replacing the whole unit

Which DVP codes and series are requested most often?

CodeDescription
SC 5Dry rotary vane vacuum pump, 5 m³/h at 50 Hz
SC 60 / SC 80Dry rotary vane vacuum pump, 60–80 m³/h at 50 Hz
SC 100 / SC 140Dry rotary vane vacuum pump, 100–130 m³/h at 50 Hz
CC 60 / CC 80Dry rotary vane vacuum pump, 60–80 m³/h at 50 Hz
LC 4BLubricated vane pump for low vacuum, 4 m³/h at 50 Hz
LC 41 / LC 61Lubricated vane pump, 40–60 m³/h at 50 Hz, with the LC 41WR and LC 61WR versions
LC 205 / LC 305Lubricated vane pump, 205–305 m³/h at 50 Hz
LX 550 / LX 650Lubricated vane pump, 550–650 m³/h at 50 Hz
PA 155 / PA 315Claw pump, 155–250 m³/h at 50 Hz
VB 315Claw pump, 315 m³/h at 50 Hz
CPAP Duplex / TriplexClaw pump, 310–750 m³/h at 50 Hz
RC 4M / RC 8MHigh-vacuum vane pump, oil sealing

Where is DVP equipment used?

  • Packaging — vacuum pumps for packaging lines
  • Environmental protection — vacuum applications in environmental plants
  • Chemical industry — claw pumps and high-vacuum pumps for processes with dry suction
  • Refrigeration and air conditioning — high-vacuum pumps for refrigeration systems
  • Metallurgy and analytical work — RC and DC high-vacuum pumps for metallurgical applications and analytical instruments

How do we supply DVP in Romania?

For DVP we can quote vane vacuum pumps, dry or lubricated, claw pumps, high-vacuum pumps, accessories and spare parts, namely vanes, oils and kits. To identify the item quickly, send the series from the nameplate, for example LC 61 or SC 80, the rated flow rate, the motor voltage and the gas or air drawn in, with any moisture. For parts, the approximate age of the pump also helps. Pumps are supplied to order, usually in 1–4 weeks; vanes and oils can ship in 24–72 h when the item is in stock, locally or at the supplier. The exact lead time is confirmed in the quotation.

For lubricated pumps, we define the oil version and the exhaust configuration in the quotation, based on the nameplate data and the gas drawn in.

Frequently asked questions about DVP

Which DVP families exist besides the SC, CC and LC vane pumps: claw, piston, lobe, blowers?

DVP Vacuum Technology, from San Pietro in Casale, makes dry and lubricated rotary vane pumps, claw, piston and lobe pumps, blowers, high-vacuum pumps, industrial vacuum systems, filters and spare parts. We can quote by family, depending on the application.

How do I choose between a dry SC pump and a lubricated LC pump?

Dry SC and CC pumps have no oil in the pumping chamber, but they do not accept air containing moisture, oil or liquids. Lubricated LC pumps have sealing oil, and the WR versions have a reinforced gas ballast for humid air. Send us the gas being drawn in and the flow rate required.

What flow and power do DVP LC 41 and LC 61 pumps have at 50 Hz?

At 50 Hz, the LC 41 has a nominal flow of 40 m³/h and a 1.1 kW motor, while the LC 61 has 60 m³/h and 1.5 kW. Both reach an ultimate pressure of 0.1 mbar (abs.) and succeed the LC 40 and LC 60 respectively, with the same installation dimensions. We confirm the exact variant with the quotation.

Can I replace the vanes of an older DVP pump?

As a rule, yes. Vanes are selected by pump series, for example LC 41 or SC 60, and the spare parts kits by the same series. We need the series from the nameplate and, if you have one, a photo of the nameplate, so that we can confirm the correct item in the quotation.

What application details are needed for a PA, VB or CPAP claw pump?

The series you want or the flow rate required in m³/h, the ultimate pressure required, the supply voltage, and whether the pump works with clean air or with vapours. For PA, VB or CPAP, also state the installation location, so that we can choose the suitable version.

How do I request a DVP quotation?

Send the DVP code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: DVP Vacuum Technology S.p.A. (manufacturer documentation)