Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

INFICON supplier in Romania

For INFICON we quote CDG capacitive gauges, PSG Pirani and BAG Bayard-Alpert probes, VGC controllers, LDS3000 and UL1000 Fab leak detectors and ISO-KF vacuum components, on the basis of the probe code, the pressure range and the flange.

Headquarters: Bad Ragaz, Switzerland

Request a quote

Who is INFICON and what does it make?

INFICON is a Swiss company headquartered in Bad Ragaz, listed on the Swiss stock exchange since 2000, which makes instruments and sensors for vacuum, leak detection, gas analysis and process monitoring. Its factories are in Europe, the United States and China. For industry working with vacuum, three areas matter: vacuum gauges and controllers, helium and hydrogen leak detectors, and vacuum components (flanges, seals, feedthroughs, bellows).

The gauges cover a wide pressure range, from atmospheric to ultra-high vacuum. Ceramic-diaphragm capacitive gauges (CDG) are grouped into series such as Porter CDG020D, SKY CDG025D up to CDG200D, Edge with EtherCAT, high-speed Stripe, Cube CDGsci and the Spot miniatures for integration into OEM equipment. Pirani probes (PSG, PGE, PPG), hot-cathode Bayard-Alpert ionisation probes (BAG, BPG, Trigon), Gemini MxG5xx cold-cathode probes and the BCG450, PCG55X and MPG40X combinations complete the range, alongside controllers such as VGC50x, TPG36x and VGD500. For leak detection, the LDS3000, UL6000 Fab, UL3000 Fab, UL1000 Fab series and the Protec P3000 sniffers look for helium or hydrogen leaks.

Such instruments appear in Romania in process vacuum installations, in thin-film coating equipment, in research laboratories and in lines for testing the tightness of parts. For a replacement, the measuring principle, the pressure range, the flange (for example ISO-KF or ISO-CF) and the electrical interface matter, so the request starts from the code on the probe.

What do we supply from the INFICON range?

ProductDescription
CDG capacitive gauges (SKY, Edge, Stripe, Cube)Ceramic-diaphragm gauges, independent of the type of gas: SKY with temperature compensation or control, Edge and Stripe with EtherCAT (Stripe high-speed), Cube CDGsci as a high-accuracy reference standard, without a separate controller.
Pirani, Bayard-Alpert and cold-cathode probesThermal-conductivity probes (PSG, PGE, PPG) for the range from atmospheric to medium vacuum, hot-cathode ionisation probes (Trigon BAG552, BPG400, PBR 260) for high and ultra-high vacuum, and Gemini MxG5xx cold-cathode probes, without a filament.
Helium leak detectors (LDS3000, UL6000 Fab, UL1000 Fab)LDS3000 is a modular detector, easy to integrate into systems; UL6000 Fab is mobile, for large volumes, and UL1000 Fab is a version for industry and semiconductors; XL3000flex also detects hydrogen, and Protec P3000 is a sniffer for production.
Vacuum controllers and switchesVGC50x, TPG36x, PGD500 and VGD500 controllers that read, display and control the vacuum probes, plus VSA100A, VSC150A, VSA200 and VSD200 vacuum switches, used as alarms and safety interlocks when the pressure in the installation goes outside the permitted limits.

Why INFICON?

  • The main vacuum measuring principles: capacitive (CDG), Pirani, hot-cathode ionisation, cold cathode and combinations, from atmospheric pressure to ultra-high vacuum
  • Gas-independent capacitive gauges: the ceramic diaphragm measures pressure regardless of the type of gas, in series from Porter to Cube CDGsci
  • Modern interfaces: Edge and Stripe series with EtherCAT, for direct integration into the equipment network
  • Leak detection with helium and hydrogen: from the modular LDS3000 to the UL6000 Fab for large volumes and the Protec P3000 sniffer
  • Vacuum components in the same quotation: ISO-KF, ISO-K, ISO-F and ISO-CF, with seals, bellows, adapters and feedthroughs

Which INFICON codes and series are requested most often?

CodeDescription
CDG015DCapacitive gauge with 4–20 mA current loop, IP65
Porter CDG020DCompact capacitive gauge with alumina sensor
SKY CDG025DCapacitive gauge with temperature compensation
SKY CDG045DCapacitive gauge with controlled temperature
Edge CDG045D2Capacitive gauge with EtherCAT
Stripe CDG045DhsHigh-speed capacitive gauge with EtherCAT
Cube CDGsciReference gauge with integrated functions
PSG55xPirani probe, range from atmospheric to medium vacuum
PCG55XCombined Pirani and capacitive probe
Trigon BAG552Bayard-Alpert hot-cathode ionisation probe
MPG40XCombined cold-cathode and Pirani probe
VGC50xController for vacuum probes
LDS3000Modular helium leak detector
UL1000 FabHelium leak detector, industrial version
Protec P3000Helium sniffer for production

Where is INFICON equipment used?

  • Process vacuum equipment: gauges and controllers on chambers and lines
  • Thin films and coatings: pressure probes for vacuum processes
  • Research and laboratories: CDGsci reference standards and high-vacuum probes
  • Leak-tightness testing in production: helium and hydrogen detectors, sniffers
  • Semiconductors: UL3000 Fab detectors and vacuum components

How do we supply INFICON in Romania?

We can quote INFICON vacuum gauges and probes, controllers, vacuum switches, helium leak detectors and vacuum components, supplied to order. The lead time is usually 1–4 weeks to order and may be longer for configured detectors or complex systems. For a correct quotation, send us the complete code of the probe or detector, the pressure range, the flange (ISO-KF, ISO-K or ISO-CF), the type of output or interface (analogue, EtherCAT) and the process gas.

A vacuum probe is recommended on the basis of the pressure range and the process gas, and replacements between different measuring principles are discussed separately.

Frequently asked questions about INFICON

What does INFICON make for vacuum technology?

INFICON makes vacuum gauges and probes (capacitive, Pirani, hot-cathode ionisation, cold cathode), vacuum controllers and switches, helium and hydrogen leak detectors and ISO-KF, ISO-K, ISO-F and ISO-CF vacuum components. The company is headquartered in Bad Ragaz, Switzerland.

How do I choose between a capacitive gauge, a Pirani and a Bayard-Alpert?

The capacitive gauge measures pressure independently of the type of gas, the Pirani probe covers the range from atmospheric pressure to medium vacuum, and the hot-cathode ionisation probe works at high and ultra-high vacuum. Send us the pressure range, the process gas and the flange, and we propose the suitable probe or combination.

Do you supply INFICON equipment in Romania and how quickly?

INFICON probes, controllers and detectors are supplied to order, usually in 1–4 weeks. Configured detectors and complex systems may have longer lead times. The exact lead time appears in the quotation, after the complete code of the probe or detector has been checked.

Can I replace an old INFICON probe with one from the current series?

This can be checked on the basis of the code on the probe, the pressure range, the flange and the electrical connector. A direct replacement between different series is confirmed after comparing the output signal and the controller used; send the code of the probe and of the controller.

What data should I send for a quotation on INFICON probes or detectors?

For probes: the code or measuring principle, the pressure range, the flange, the gas and the electrical interface. For leak detectors: the volume tested, the test gas (helium or hydrogen), the method (vacuum or sniffer) and the leak level targeted. Add the quantity and the application.

How do I request a INFICON quotation?

Send the INFICON code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: INFICON (manufacturer documentation)