For ERIFLEX we quote FLEXIBAR and Flexibar Advanced flexible busbars, IBS and PBC flexible braids, CPI and MBJ earthing braids, ISO insulators and BC, FBC, FC, HCBC and QCC clamps; we need the cross-section and the current.
Who is ERIFLEX and what does it make?
ERIFLEX makes solutions for low-voltage distribution: flexible busbars, braids and shunts, insulators, clamps, DIN profiles, protective covers and installation tools. The FLEXIBAR flexible busbar replaces the rigid conductor or the cable in electrical panels and in the connections between transformer, busbar trunking and cabinets, where space is limited.
The flexible busbar is made of several layers of thin electrolytic copper, insulated with a self-extinguishing PVC compound or with silicone. It bends, folds or twists with a very small bending radius, so the connections come out shorter and more compact, without separate cable lugs. The connection is made by drilling and bolting directly through the copper laminations, by clamps at the end of the busbar or by welding. The range extends from 7 mm² to 1200 mm² and from 125 A to 2800 A. The Flexibar Advanced version, made of tinned copper, has low-smoke, flame-retardant, halogen-free insulation.
The family also includes IBS, IBSB, IBSHY and PBC flexible power braids, CPI, MBJ, MBJYG and BJ earthing and equalising braids, ISO and ISO-TP low-voltage insulators, EB earth and neutral bars, copper busbars, busbar supports, BC, FBC, FC, HCBC and QCC clamps and connectors, DIN profiles, cable sleeves and hydraulic and manual tools for installing the busbars.
What do we supply from the ERIFLEX range?
| Product | Description |
|---|---|
| FLEXIBAR and Flexibar Advanced | Flexible busbars made of thin layers of electrolytic copper, insulated with self-extinguishing PVC or silicone. The Advanced version, made of tinned copper, has halogen-free, low-smoke insulation. They are used between transformer, busbar trunking and cabinets. |
| Flexible power braids and shunts | The IBS, IBSB, IBSHY and PBC families are flexible braids and shunts for electrical connections that move or vibrate. The choice is made by cross-section, length and the type of ends; the data on the drawing or on the old part help with identification. |
| Earthing and equalising braids | The CPI, MBJ, MBJYG and BJ series, plus coiled braids, for earthing and potential equalisation connections in panels and installations. They are chosen by cross-section, length and the type of terminals. |
| Insulators, supports, clamps and connectors | ISO and ISO-TP low-voltage insulators, adjustable, compact, flat and universal busbar supports, EB earth bars and BC, FBC, FC, HCBC and QCC clamps for busbars. They are chosen by the thickness and width of the busbar and by the mounting system. |
Why ERIFLEX?
- Flexible busbars made of insulated copper laminations — they bend with a small radius and shorten the connections in tight panels
- Cross-sections from 7 to 1200 mm² and currents from 125 to 2800 A — the same family covers everything from small branches to transformer connections
- Flexibar Advanced made of tinned copper, with flame-retardant, halogen-free, low-smoke insulation — suited to spaces where fire behaviour matters
- Connection by drilling and direct bolting, by clamps or by welding — without separate cable lugs
- Braids, insulators, clamps and supports from the same family — one quotation for the whole distribution assembly
Which ERIFLEX codes and series are requested most often?
| Code | Description |
|---|---|
| FLEXIBAR | Flexible busbar made of copper laminations insulated with PVC or silicone |
| Flexibar Advanced | Flexible busbar made of tinned copper, with halogen-free, low-smoke insulation |
| IBS | Flexible power braid |
| IBSB | Flexible power braid |
| IBSHY | Flexible power braid |
| PBC | Flexible power braid |
| CPI | Earthing and equalising braid |
| MBJ | Earthing and equalising braid |
| BJ | Earthing and equalising braid |
| ISO | Low-voltage insulator |
| ISO-TP | Low-voltage insulator |
| BC | Clamp for busbars |
| FBC | Clamp for busbars |
| HCBC | Clamp for busbars |
| QCC | Clamp or connector for busbars |
Where is ERIFLEX equipment used?
- Low-voltage electrical panels — flexible busbars and distribution connectors
- Transformer, busbar trunking and cabinet connections — FLEXIBAR and Flexibar Advanced
- Earthing and potential equalisation — CPI, MBJ and BJ braids
- Power distribution in industrial installations — clamps, supports and insulators
How do we supply ERIFLEX in Romania?
We can quote ERIFLEX FLEXIBAR and Flexibar Advanced flexible busbars, braids and shunts, insulators, supports and clamps. For an accurate quotation, send the cross-section needed in mm², the rated current, the length, the type of insulation desired, for example PVC or silicone, and, for an existing assembly, a photo of the connection with the measured dimensions. Items are supplied to order, usually in 1–4 weeks; depending on the specification, the lead time may be longer and is confirmed in the quotation.
Configurations with special lengths and ends are quoted based on the drawing or the old part, and the fit is checked in the quotation before the order.
Frequently asked questions about ERIFLEX
Which product families does ERIFLEX include for low-voltage distribution, from FLEXIBAR to flexible braids?
ERIFLEX makes FLEXIBAR and Flexibar Advanced flexible busbars, flexible and earthing braids, insulators, supports and clamps for busbars, copper busbars, DIN profiles and installation tools, all for low-voltage distribution.
How do I choose a flexible busbar for my connection?
Start from the rated current, the cross-section in mm² and the mounting space. The range runs from 7 to 1200 mm² and from 125 to 2800 A. The insulation also matters: PVC or silicone on FLEXIBAR, halogen-free insulation on Flexibar Advanced. Send these data.
Do you supply ERIFLEX in Romania, and how fast?
Yes. ERIFLEX items can ship in 24–72 h when the item is in stock, locally or at the supplier, and an item supplied to order usually arrives in 1–4 weeks. For special lengths the lead time may be longer; we confirm it in the quotation.
Can I replace a cable or a rigid busbar with FLEXIBAR?
The flexible busbar bends with a small radius and needs less mounting space. We check case by case based on the current, the cross-section and the length between the connection points; send the sketch of the connection and, if there is one, the photo.
How do I request a quotation for braids or shunts from the IBS, PBC, CPI or MBJ series?
The series if you know it, for example IBS, PBC, CPI or MBJ, the cross-section, the length, the type of ends and the current. For earthing braids, the diameter of the holes at the ends also matters; we confirm the suitable version in the quotation.
How do I request a ERIFLEX quotation?
Send the ERIFLEX code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: ERIFLEX (manufacturer documentation)