Gavardo Caldaie supplier in Romania

For Gavardo Caldaie we quote FB and OMG steam generators, OMD and OMDV thermal oil heaters and containerised boiler plants; for a quotation we need the steam output or the power, the pressure, the fuel and the series from the nameplate.

Request a quote

Who is Gavardo Caldaie and what does it make?

Gavardo Caldaie is an Italian manufacturer of saturated steam generators and forced-circulation thermal (diathermic) oil heaters, used for thermal energy in industrial processes. The range includes the FB vertical and OMG horizontal steam generators, the OMD horizontal and OMDV vertical thermal oil heaters and the heating plants mounted in containers. All work with gas, LPG or diesel burners, with an integrated IP65 electrical panel and two-stage or modulating operation; for FB, OMG and OMD there is also a progressive version.

The design principle is forced circulation: softened water or thermal oil circulates through a coil of variable cross-section, heated by the flame and the flue gases of the burner. The small water content of the coil reduces the risk of explosion, and the coil can be replaced, so the unit can be returned to working order after damage. FB is compact, with two gas passes, 88% efficiency and a steam output of 125–700 kg/h. OMG has three gas passes, 90% efficiency and 200–3000 kg/h. The OMD thermal oil heaters cover 116–3489 kW, and OMDV 116–1163 kW, both with three gas passes and 86% efficiency. The ISO container versions, for OMG generators and OMD heaters, reduce civil works.

Saturated steam is used directly, in contact with the product, or indirectly, as an energy-carrying fluid. Such equipment matters in industrial laundries, the textile, food, chemical and dairy industries and in oil and gas.

What do we supply from the Gavardo Caldaie range?

ProductDescription
FB vertical steam generatorForced-circulation saturated steam generator, vertical version, compact, monobloc, with two gas passes and 88% efficiency. It produces 125–700 kg/h, with a gas, LPG or diesel burner and an integrated IP65 electrical panel.
OMG horizontal steam generatorForced-circulation saturated steam generator, horizontal version, of solid construction, with three gas passes and 90% efficiency. Steam output is 200–3000 kg/h, with two-stage, progressive or modulating operation.
OMD and OMDV thermal oil heatersForced-circulation (coil) diathermic oil heaters: OMD horizontal, 116–3489 kW, and OMDV vertical, compact, 116–1163 kW. They have three gas passes, 86% efficiency and gas, LPG or diesel burners.
Containerised heating plantsComplete heating plants mounted in ISO containers, with an OMG steam generator or an OMD thermal oil heater. The solution simplifies civil works and frees covered space for other activities.

Why Gavardo Caldaie?

  • Forced circulation through a coil — a generator with a small water reserve
  • Replaceable coil — the unit can be returned to working order after damage, without replacing the whole generator
  • Two steam generator versions — FB vertical, compact, 125–700 kg/h, and OMG horizontal, 200–3000 kg/h, with efficiencies of 88% and 90%
  • OMD and OMDV thermal oil heaters — 116–3489 kW and 116–1163 kW respectively, for high-temperature processes
  • Heating plants in ISO containers — for OMG generators and OMD heaters, with reduced civil works

Which Gavardo Caldaie codes and series are requested most often?

CodeDescription
FBVertical steam generator, 125–700 kg/h, 88% efficiency
OMGHorizontal steam generator, 200–3000 kg/h, 90% efficiency
OMDHorizontal thermal oil heater, 116–3489 kW
OMDVVertical thermal oil heater, 116–1163 kW
OMG containerContainerised heating plant with OMG generator
OMD containerContainerised heating plant with OMD heater
NFxxxxSerial format on the nameplate of steam generators
xxxxxSerial format on the nameplate of thermal oil heaters

Where is Gavardo Caldaie equipment used?

  • Industrial laundries and ironing — FB and OMG compact steam generators
  • Textile industry — saturated steam for industrial processes
  • Chemical industry — steam or thermal oil for heating processes
  • Food industry — process steam at a temperature set by pressure
  • Oil and gas — thermal oil heaters and steam generators

How do we supply Gavardo Caldaie in Romania?

We can quote FB and OMG steam generators, OMD and OMDV thermal oil heaters, containerised heating plants, spare parts and coils. For a quotation we need the steam output or the thermal power, the working pressure and temperature, the fuel available, the installation space and, for an existing unit, the serial number from the nameplate: NF followed by four digits on steam generators, five digits on thermal oil heaters. Supplied to order; usually 1–4 weeks for parts, and depending on the specification the lead time may be longer for complete generators. The exact lead time is confirmed in the quotation.

Parts for an older generator are identified from the series on the nameplate and the exact model of the unit.

Frequently asked questions about Gavardo Caldaie

What does Gavardo Caldaie make?

Gavardo Caldaie makes forced-circulation saturated steam generators (FB vertical and OMG horizontal), forced-circulation thermal oil heaters (OMD horizontal and OMDV vertical) and complete heating plants in containers, with gas, LPG or diesel burners.

How do I choose between an FB and an OMG generator?

FB is vertical, compact, with two gas passes and a steam output of 125–700 kg/h, suited to small spaces. OMG is horizontal, with three gas passes and 200–3000 kg/h. Send us the steam output, the working pressure and the space available.

Can you supply Gavardo Caldaie equipment to Romania, and how fast?

Yes, the units are supplied to order. Parts usually arrive in 1–4 weeks, while complete generators and containerised plants have a longer lead time, confirmed in the quotation once the power, the pressure and the fuel are set.

Where do I find the unit's serial number to request parts?

The serial is on the machine's nameplate. On steam generators it has the form NF followed by four digits, for example NF6415, and on thermal oil heaters it has five digits. Send us the serial and the unit type and we check the parts needed.

What data is needed for a containerised heating plant?

We need the unit type (OMG steam generator or OMD oil heater), the power or the steam output, the pressure and the temperature, the fuel and the siting conditions. With them we prepare the quotation for a complete plant, mounted in an ISO container.

How do I request a Gavardo Caldaie quotation?

Send the Gavardo Caldaie code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: Gavardo Caldaie (manufacturer documentation)