Keller HCW supplier in Romania
For Keller HCW we offer CellaTemp PX, PA, PK and PR pyrometers, CellaPort PT and Mikro PV 11; we need the temperature range, the distance and the size of the target, the desired interface and the code on the existing pyrometer.
Headquarters: Ibbenbüren, Germany
Who is Keller HCW and what does it make?
Keller HCW is a German company based in Ibbenbüren, and its pyrometer line serves non-contact temperature measurement in industrial processes. The CellaTemp, CellaPort and Mikro pyrometers cover the range from -30 to 3,500 °C and solve a simple process problem: the temperature of a product or a furnace is read from a distance, without a probe inserted in the material, where direct contact is not possible or not desirable.
The families are chosen by mounting method. The stationary CellaTemp PX (0–3,000 °C, IO-Link digital interface per IEC 61131-9) and PA (0–3,500 °C, USB and RS 485 interface) series have adjustable lenses, with a measuring spot from 0.1 mm, for long distances and small targets. The compact CellaTemp PK (-30 to 2,500 °C, with display and buttons), PKF (separate optical head, with optical fibre, for tight spaces), PKL (with LED aiming light) and PR (0–1,600 °C) series integrate into production lines. CellaPort PT is the portable version, and Mikro PV 11 is an optical intensity comparison pyrometer, from 700 to 3,500 °C, for objects from 0.1 mm.
For applications with special requirements there are dedicated versions, for example CellaCast for liquid metal, CellaCombustion for sooty flames and hot gases in power plants and incinerators, CellaCrystal for the growth of silicon and silicon carbide crystals, CellaWafer for semiconductor wafers. From the Keller HCW range we offer only the pyrometers. For replacements, the quotation starts from the pyrometer code; for new installations, from the material measured, the temperature and the measuring distance.
What do we supply from the Keller HCW range?
| Product | Description |
|---|---|
| CellaTemp PX and PA | Stationary pyrometers with an adjustable lens, spot from 0.1 mm and sighting through the lens or with a pilot laser. PX goes from 0 to 3,000 °C and has an analogue output plus IO-Link, while PA reaches 3,500 °C, in a stainless steel housing, with analogue outputs and a USB or RS 485 interface. |
| CellaTemp PK, PKF, PKL and PR | Compact pyrometers for automated lines. PK covers -30 to 2,500 °C, with display and buttons; PKF has an optical head with fibre for small spaces, PKL has LED aiming, and PR goes from 0 to 1,600 °C, with digital reading through IO-Link. |
| CellaPort PT and Mikro PV 11 | CellaPort PT is a portable single-colour pyrometer from 0 to 3,500 °C, with sighting through the lens or a pilot laser and a USB interface, for quick diagnosis. Mikro PV 11 is an intensity comparison pyrometer, from 700 to 3,500 °C, for filaments and very small samples. |
| Special versions and measuring systems | CellaCast measures liquid metals at casting machines and melting furnaces, CellaCombustion works in combustion chambers, CellaCrystal in crystal furnaces, CellaWafer on semiconductor wafers. A complete system brings together the pyrometer, the mounting assembly and the suitable electrical accessories. |
Why Keller HCW?
- Wide temperature range — from -30 to 3,500 °C, with different series for each interval, from sheet metal to very high temperature furnaces
- Adjustable optics — PX and PA measure small targets, from 0.1 mm, from long distances, with sighting through the lens or a pilot laser
- Mounting in production lines — PK and PR have a compact housing, an IO-Link interface and, on the PK, a local display with parameter buttons
- Versions for difficult processes — CellaCast for liquid metal, CellaCombustion for sooty flames, CellaCrystal for crystal growth
- Complete measuring systems — the pyrometer is supplied together with the mounting assembly and the electrical accessories suited to the application
Which Keller HCW codes and series are requested most often?
| Code | Description |
|---|---|
| CellaTemp PX | Stationary pyrometer, 0–3,000 °C, IO-Link |
| CellaTemp PA | Stationary pyrometer, 0–3,500 °C, USB and RS 485 |
| CellaTemp PK | Compact pyrometer with display, -30 to 2,500 °C |
| CellaTemp PKF | Compact pyrometer with separate optical head and optical fibre |
| CellaTemp PKL | Compact pyrometer with LED aiming light |
| CellaTemp PR | Compact pyrometer, 0–1,600 °C, IO-Link |
| CellaPort PT | Portable single-colour pyrometer, 0–3,500 °C, USB |
| Mikro PV 11 | Optical intensity comparison pyrometer, 700–3,500 °C |
| CellaCast PX / PA / PT | Pyrometers for liquid metal, stationary and portable |
| CellaCombustion PK / PX / PA / PT | Spectral pyrometers for combustion processes |
| CellaCrystal PX / PA | Pyrometers for the growth of silicon and silicon carbide crystals |
| CellaFurnace PX / PA | Pyrometers for industrial furnaces |
| CellaWafer PA / PK | Pyrometers for semiconductor wafers |
Where is Keller HCW equipment used?
- Steel industry — rolling mills, continuous annealing and continuous casting lines
- Glass and building materials — glass, cement and lime furnaces
- Foundries and forging — liquid metal, induction heating
- Power plants and incinerators — temperature of flames and hot gases in combustion chambers
- Semiconductors and crystals — growth and heat treatment processes
How do we supply Keller HCW in Romania?
We can quote Keller pyrometers from the CellaTemp PX, PA, PK, PKF, PKL and PR series, CellaPort PT portable pyrometers and the Mikro PV 11 pyrometer, to order. The lead time is usually 1–4 weeks; depending on the specification, the lead time may be longer for special versions or for complete systems with mounting. For a correct quotation, send us the code on the nameplate, for replacements, or the material measured, the temperature range, the distance to the target, the size of the target, the desired interface (analogue, IO-Link, USB, RS 485) and the conditions at the mounting location, that is dust, ambient temperature and vibration.
The suitable series is determined on the basis of the target material, the temperature range and the measuring distance.
Frequently asked questions about Keller HCW
What pyrometers does Keller HCW make?
Keller HCW makes pyrometers for non-contact temperature measurement, between -30 and 3,500 °C: CellaTemp PX, PA, PK, PKF, PKL and PR for fixed mounting, portable CellaPort PT and Mikro PV 11 for very small objects. There are also versions for liquid metal, combustion, crystal growth and semiconductor wafers.
How do I choose between the PX, PA and PK series?
PX and PA have an adjustable lens and are chosen for long distances or small targets, from 0.1 mm; PA reaches 3,500 °C and has USB or RS 485, PX has IO-Link. PK is compact, with display and buttons, for production lines with little space. Send us the temperature, the distance and the size of the target.
Are Keller pyrometers supplied in Romania and how fast?
Yes; supply is to order for Keller HCW items. The pyrometer can ship in 24–72 h when the item is in stock, locally or at the supplier. Special versions and complete systems with mounting may take longer, and the exact lead time is given in the quotation.
Can I replace an older Keller pyrometer with a CellaTemp series?
It can be checked; the equivalence is confirmed on the basis of the technical data. What matters are the temperature range, the optics, the type of aiming, the output (analogue or digital) and the mounting connection. Send the code on the nameplate and a photo of the installation, and we compare the data with the current series.
What do I need to send for a quotation on a pyrometer?
Send the material and the size of the target, the temperature range, the measuring distance, the desired type of sighting (through the lens, laser or LED), the interface (analogue, IO-Link, USB or RS 485), the power supply and the conditions at the mounting. For an existing pyrometer, add the complete code from the nameplate.
How do I request a Keller HCW quotation?
Send the Keller HCW code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Keller HCW GmbH (manufacturer documentation)