Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Kobold supplier in Romania

From the Kobold range we offer DUK ultrasonic flow meters, MIM and MIK electromagnetic flow meters, DON-H and DOE oval gear flow meters and NRE radar level sensors; we start from the type code.

Founded in 1980 · Headquarters: Hofheim am Taunus, Germany

Request a quote

Who is Kobold and what does it make?

Kobold Messring is a German manufacturer of industrial instrumentation for measuring and controlling flow, level, pressure and temperature. It develops compact, robust and accurate sensors and transmitters for process applications in chemicals, petrochemicals, pharmaceuticals, food, water treatment and industrial automation.

Kobold describes its activity through three directions: measurement, monitoring and analysis. The range includes variable-area float flow meters (rotameters), ultrasonic and magnetic-inductive flow meters, magnetic float level switches, pressure transducers and temperature sensors.

Kobold offers a wide range of standard configurations plus the possibility of customisation - choice of materials (stainless steel, Hastelloy, PTFE, PVDF), process connections, signal outputs, alarm limits. Integration into industrial control systems is done through 4-20mA, 0-10V, HART, PROFIBUS and Modbus outputs.

What do we supply from the Kobold range?

ProductDescription
Variable-area float flow meters (rotameters)Mechanical flow meters with a tapered tube and float, for liquids and gases. Principle: the fluid flows through the vertical tapered tube and lifts the float until its weight is balanced by the buoyancy force, and the position of the float indicates the flow rate on the graduated scale.
Magnetic float level switchesMagnetic float level switches detect the presence of liquid in tanks, pipes and separators. The float contains a permanent magnet which, when the level reaches a certain point, activates a reed contact inside the sealed tube. The series differ in materials, contact type, mounting, maximum temperature and maximum pressure. Applications: minimum/maximum level alarms, pump control, dry-run protection.
SEN/PAD series pressure transducersKobold pressure transducers are selected by series and model.
NRE series radar level sensorsThe non-contact radar level sensors in the Kobold range are selected by series and model.

Why Kobold?

  • Compact dimensions - exact dimensions are in the data sheet of each model
  • Accuracy depends on the series and is stated in the data sheet of each model
  • Materials: 316L stainless steel, Hastelloy C, titanium, PTFE, PVDF for aggressive media
  • Temperature ranges differ by series and are stated in the data sheet of each model
  • Maximum pressure depends on the series and is stated in the data sheet of each model
  • Variants with ATEX approvals for explosive atmospheres, according to the documentation of each model

Which Kobold codes and series are requested most often?

CodeDescription
DUKultrasonic flow meter with IO-Link, in-line mounting
MIMmagnetic-inductive flow meter, full stainless steel body
MIKmagnetic-inductive flow monitor with IO-Link
DON-Hoval gear positive displacement flow meter for viscous liquids
DOEoval gear positive displacement flow meter, compact range
DUCclamp-on ultrasonic flow meter, no contact with the fluid
PITe/UMF-2insertion-type magnetic-inductive flow meter for large pipes
KECthermal mass flow meter for industrial gases
MAN-SCdigital pressure gauge, battery powered
MAN-LCdigital pressure gauge with IO-Link output
ZOKcounting and batching electronics for production lines
ZOEcounting electronics for industrial processes
TWCOEM temperature sensor for integration into equipment
MMAinsertion-type temperature sensor, with or without transmitter
MWDindustrial resistance thermometer for temperature measurement

Where is Kobold equipment used?

  • Chemicals and petrochemicals - reactors, distillation, storage
  • Pharmaceutical - fermenters, bioreactors, CIP/SIP
  • Food and beverage - mixers, tanks, ingredient dosing
  • Water treatment - filtration, chemical dosing, disinfection
  • Oil and gas - separators, pumping, refineries
  • Energy - thermal power plants, steam, cooling
  • Automotive - paint shops, surface treatments, CIP
  • Pulp and paper - chemical dosing, tank level
  • HVAC - boiler plants, chillers, humidification
  • Environment - emissions monitoring, wastewater treatment

How do we supply Kobold in Romania?

We supply Kobold Messring instruments to order, and actual availability is checked case by case at the supplier. Data on measuring ranges and materials are taken from the manufacturer's technical documentation. As a general rule, typical rotameters and level switches can arrive within 24–72 h when the item is in stock, locally or at the supplier, while special configurations or instruments with rare materials follow the order flow, usually 1–4 weeks. For a correct quotation we need the measured fluid, the flow or pressure range and the type of process connection. Accredited recalibration and the issuing of calibration certificates are handled by the manufacturer's laboratory in Germany.

Availability of each Kobold configuration is checked on request; accredited recalibrations are carried out in specialised laboratories.

Frequently asked questions about Kobold

What is the difference between Kobold DUC and DUK flow meters?

The DUC is a clamp-on ultrasonic flow meter, mounted on the outside of the pipe without contact with the fluid, useful when no intervention on the pipe is wanted. The DUK is mounted in-line and communicates over IO-Link. The choice depends on whether the pipe can be interrupted and on the type of fluid measured.

What flow ranges and maximum pressure does the Kobold MIK magnetic-inductive flow meter have?

The MIK measures conductive liquids, from 0.01-0.5 l/min up to 35-700 l/min, with an accuracy of ±2.0 % of full scale. Maximum pressure is 10 bar and media temperature is -20 ... +80 °C. Connections are G ½ ... G 2¾ male threads. We confirm the exact variant at quotation.

What information do I send for a quotation for a Kobold flow meter?

We need the type of fluid measured (liquid, gas or viscous), the minimum and maximum expected flow rate, the pipe diameter, the working pressure and temperature, plus the desired output type, analogue or IO-Link. For clamp-on mounting, state the material and wall thickness of the pipe, as they directly affect the correct choice of model.

What is a Kobold MMA insertion-type temperature sensor?

The MMA is a sensor inserted directly into the fluid or medium measured, available with or without an integrated signal transmitter, suited to continuous temperature monitoring in pipes or tanks. The choice between the version with a transmitter and the plain one depends on the existing automation system and the type of signal it accepts.

How do I request a Kobold quotation?

Send the Kobold code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Kobold, KOBOLD Messring GmbH, KOBOLD Messring (manufacturer documentation)