Knick supplier in Romania

For Knick we quote high-voltage transducers, isolated signal conditioners, sensor transmitters, Memosens sensors for pH, conductivity and oxygen, and Stratos and Protos transmitters; we need the code from the device and the measuring range.

Founded in 1945 · Headquarters: Berlin, Germany

Request a quote

Who is Knick and what does it make?

Knick, based in Berlin, Germany, has made measuring and signal conditioning instruments since 1945 for two fields: interface technology and process analysis. Interface technology includes high-voltage transducers, isolated signal conditioners, sensor transmitters, signal multipliers and panel indicators. In process analysis, the brand supplies Memosens sensors, fittings, transmitters and automation systems for measuring pH, redox potential, conductivity and oxygen.

The interface technology family starts with isolated conditioners only 6 mm wide, such as A21000, A20100 and some BL models, and extends to high-voltage transducers with isolation of up to 4,800 V, such as P52000 and P45000, the latter in a SIL 2/SIL 3 version (functional safety integrity levels). Sensor transmitters take signals from resistance thermometers, thermocouples, strain gauges and potentiometers, while signal multipliers duplicate speed signals or standard signals for several consumers.

In process analysis, Memosens technology connects the sensor to the transmitter by inductive coupling, without galvanic contact, which makes the connection resistant to moisture and interference. The sensor series cover pH (SE554, SE555, SE515), conductivity (SE603, SE655) and optical oxygen (SE740), and the transmitters include Stratos, Protos, MemoRail and Portavo. What matters for a quotation is the complete code from the device, the input and output signal, the supply voltage and, for sensors, the medium and process temperature.

What do we supply from the Knick range?

ProductDescription
High-voltage transducersThe P41000, P42000, P43000, P45000, P51000 and P52000 series measure current and voltage with high isolation. P52000 covers ranges from 0…±100 V to 0…±4,800 V, with isolation of up to 4,800 V; P45000 is available in a SIL 2/SIL 3 version.
Isolated signal conditionersP27000 offers 480 calibrated, switchable measuring ranges, P15000 has high isolation, and A20400 and P22400 are powered from the current loop, the latter for safety circuits up to SIL 3. Models such as A21000, A20100, BL510 or BL560 have a housing only 6 mm wide.
Sensor transmitters and multipliersP32000 and P32100 take signals from resistance thermometers, thermocouples and resistors, P32200 from strain gauges, and P44000 measures temperature with a Pt100 input and high isolation. P16800 duplicates speed signals, and P16000 conditions pulse frequency signals.
Memosens process analysispH sensors (SE554, SE555, SE515), conductivity sensors (SE603, SE655), oxygen sensors (SE740), Stratos Pro A201 and Protos II 4400 transmitters, SensoGate WA131M retractable fittings and the cCare automatic maintenance system.

Why Knick?

  • High-voltage transducers with isolation of up to 4,800 V — safe galvanic separation between the measuring circuit and the automation
  • SIL 2/SIL 3 versions of the P45000 transducers and P32000 transmitters — they can be used in functional safety circuits
  • Isolated conditioners in a 6 mm housing — they save space in dense automation cabinets
  • Inductive Memosens connection between sensor and transmitter — no contact exposed to moisture or corrosion
  • The same brand covers the cabinet signal and the measurement in the liquid — one manufacturer for both instrumentation tasks

Which Knick codes and series are requested most often?

CodeDescription
P52000High-voltage transducer, ranges up to 0…±4,800 V
P45000High-voltage transducer in a SIL 2/SIL 3 version
P42000Calibrated, switchable transducer, ranges up to 3,600 V
P27000Isolated signal conditioner with 480 measuring ranges
P22400Loop-powered conditioner, for safety circuits up to SIL 3
P32000Isolated sensor transmitter, SIL 2/SIL 3
P44000Temperature transmitter with Pt100 input and high isolation
SE555Memosens pH sensor, sterilisable, for aggressive media
SE603Conductivity sensor with 4 electrodes, corrosion-resistant
SE740Optical oxygen sensor for hygienic environments
Stratos Pro A201Transmitter for pH, redox and conductivity
Protos II 4400Modular multiparameter transmitter
WA131MSensoGate retractable fitting

Where is Knick equipment used?

  • Rail — transducers for measuring voltage and current on vehicles and infrastructure
  • Power generation and storage — isolated measurements on high-voltage circuits
  • Pharmaceutical and biotechnology industry — pH and oxygen sensors with sterilisable versions
  • Chemicals and food and beverages — pH, redox and conductivity in the process
  • Water and wastewater treatment — sensors and transmitters for continuous monitoring

How do we supply Knick in Romania?

We can quote Knick transducers and signal conditioners for automation cabinets, as well as sensors, fittings and transmitters for process analysis. For an accurate quotation, send the complete code from the device or sensor, the input and output signal, the supply voltage and, for sensors, the medium, temperature and process pressure. Knick parts are supplied to order, usually in 1–4 weeks; a part can ship in 24–72 h when the item is in stock, locally or at the supplier. The exact date is given in the quotation.

Codes with suffixes or versions with Ex certification are defined in the quotation, based on the device nameplate and the process data received.

Frequently asked questions about Knick

What are P42000, P52000, SE555 and Stratos Pro A201 at Knick?

P42000 and P52000 are high-voltage transducers, with ranges up to 3,600 V and 4,800 V respectively. SE555 is a sterilisable Memosens pH sensor for aggressive media, and Stratos Pro A201 is a transmitter for pH, redox and conductivity.

How do I choose between a P42000 and a P52000 transducer?

The choice starts from the voltage to be measured and the isolation required. P42000 covers ranges up to 3,600 V, and P52000 up to 4,800 V, with matching isolation. The output signal and the supply also matter. Send us the range and the circuit type, and we identify the suitable version.

Do you supply Knick in Romania, and how quickly?

Knick parts are supplied to order, usually in 1–4 weeks; for configurations with special certification the lead time can be longer. An item can ship in 24–72 h when the item is in stock, locally or at the supplier. The lead time is confirmed in the quotation.

Can I replace a Knick pH sensor with a code from another series?

Yes, if the new sensor matches the medium, the working temperature, the membrane type and the fitting it is mounted in. Series such as SE555 or SE554 differ by application. Send us the code from the sensor and the process conditions, so that we can check compatibility before the quotation.

What data do I send for a P52000 transducer or a P27000 conditioner?

The complete code from the device, the input signal (voltage, current, resistance thermometer, strain gauge), the required output signal, the supply voltage and the isolation level required. If the device works in a safety circuit, add the SIL level required.

How do I request a Knick quotation?

Send the Knick code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote