Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Multi-Wing supplier in Romania

For Multi-Wing we quote modular axial rotors, C, D, L and R series fans, O-PMAX rotors and DCmax fans, starting from diameter, airflow, static pressure and blade pitch angle.

Founded in 1938 · Headquarters: Vedbæk, Denmark

Request a quote

Who is Multi-Wing and what does it make?

Multi-Wing is a Danish manufacturer of axial fans and axial rotors (propellers) for industrial cooling and ventilation, based in Vedbæk. The range starts with modular rotors, configured from 40 blade profiles and 37 hubs, in diameters from 200 mm, and extends to complete fans with motor and housing: the C, D, L and R series, for cooling, ventilation and drying installations, and the DCmax series, for electric engine cooling on mobile machines.

For modular rotors, the blade profile, number of blades, material, direction of rotation and blade pitch angle are selected so that the duty point required for airflow and pressure is reached with high efficiency and low noise. The five materials (three thermoplastics and two aluminium alloys) cover temperatures between −40 and 400 °C. The C series (AC or EC, 380–480 V) is used on chillers, cooling towers and data centres, the L series, with diameters up to 1,800 mm, on cooling towers and dry coolers, and the D series, with IEC housing and motor, on condensers, evaporators and power generation, with options from −55 °C to +100 °C, variants for gases up to zone 1, according to the manufacturer's documentation, and IP66 protection. The R series has a symmetrical housing and reversible flow for drying rooms.

The one-piece cast rotors O-P1, O-PMAX2, O-PMAX3 and O-PMAX4 cover diameters up to 762 mm for tractors, loaders and small excavators. The offer starts from diameter, airflow, static pressure, air temperature and direction of rotation.

What do we supply from the Multi-Wing range?

ProductDescription
Modular axial rotorsRotors configured from 40 blade profiles and 37 hubs, in diameters of 200–2,746 mm, in five materials, with clockwise or anticlockwise rotation and with options of viscous clutch, flexible blade extensions (EPS) and curved blade tips (winglet).
Axial fans, C, D, L and R seriesC, compact, AC or EC, for low and medium static pressure. D, with robust housing and IEC motor, over 800 configurations. L, EC, with diameters up to 1,800 mm. R, reversible, with symmetrical housing for drying.
Rotors O-P1, O-PMAX2, O-PMAX3 and O-PMAX4One-piece cast rotors, for Tier 4F, Tier 5 and Stage V engines: O-P1 up to 508 mm, O-PMAX2 up to 520 mm, O-PMAX3 up to 600 mm, O-PMAX4 up to 762 mm, compatible with viscous clutches.
DCmax — direct current fansDCmax is the electric direct current fan for cooling propulsion systems, used on mobile machines. For a quotation, what matters is the airflow, the static pressure, the supply voltage available on the machine and the mounting space.

Why Multi-Wing?

  • Modular rotors with 40 blade profiles and 37 hubs — diameters from 200 mm, with blades cut millimetre by millimetre to the required diameter
  • Blades and pitch angle chosen for the duty point — five materials for temperatures between −40 and 400 °C and clockwise or anticlockwise rotation
  • D series with IEC housing and motor — options from −55 °C to +100 °C, ATEX variants according to the manufacturer's documentation for gases up to zone 1, IP66 and anticorrosive protection up to CX
  • L series with EC motors — diameters up to 1,800 mm, fewer fans and fewer motors for the same airflow
  • R series with reversible flow — housing with symmetrical double inlet, for drying rooms, cold stores and brick manufacturing

Which Multi-Wing codes and series are requested most often?

CodeDescription
C-seriesCompact axial fan, AC or EC, low and medium static pressure
D-seriesAxial fan with housing and IEC motor, variants for explosive atmospheres and IP66
L-seriesLarge-diameter EC axial fan, up to 1,800 mm
R-seriesReversible axial fan with symmetrical housing
DCmaxDirect current electric fan for cooling propulsion systems
PMAXHigh-pressure rotors for engine cooling
O-P1One-piece cast rotor, up to 508 mm
O-PMAX2One-piece cast rotor, up to 520 mm
O-PMAX3One-piece cast rotor, up to 600 mm
O-PMAX4One-piece cast rotor, up to 762 mm
RewakeLow-noise blade profile for the R series
OptimiserOptimiser software for selecting axial rotors
FANBASEDatabase and documentation for axial fans

Where is Multi-Wing equipment used?

  • Heating, ventilation and refrigeration — chillers, cooling towers, dry coolers and data centres
  • Cold chain — fans for cold stores and refrigerated transport
  • Underground structures — tunnel ventilation and smoke extraction from car parks
  • Energy — cooling of generators and generating sets, including rotors up to 2,438 mm
  • Mobile machinery — engine cooling for tractors, loaders and excavators

How do we supply Multi-Wing in Romania?

From the Multi-Wing range we can quote axial rotors, C, D, L and R series fans, O-PMAX rotors for engine cooling and DCmax fans. Modular rotors are configured on the duty point, so we handle them as projects. Delivery is to order, usually in 1–4 weeks; for configured rotors, depending on the specification, the lead time can be longer. For a quotation, send the required diameter, airflow and pressure, speed, air temperature, direction of rotation, motor type (AC or EC) and, for replacements, the code on the hub or blades.

Final rotor selection is made on the customer's system curve; verifying that curve on site is outside our offer.

Frequently asked questions about Multi-Wing

What does Multi-Wing make?

Multi-Wing makes modular axial rotors, complete axial fans in the C, D, L and R series, cast rotors for cooling the engines of mobile machines, and DCmax fans. It is based in Vedbæk, Denmark, and the company has operated since 1938.

How do I select an axial rotor for a cooling installation?

Start from the duty point: airflow, static pressure, speed and available diameter. Then select the blade profile, material, pitch angle and direction of rotation. Send this data and the air temperature so the suitable rotor can be checked before the quotation.

Do you supply Multi-Wing fans in Romania and how fast?

Yes. The lead time is 24–72 h when the item is in stock, locally or at the supplier; configured rotors are supplied to order, usually in 1–4 weeks. Depending on the specification, the lead time can be longer for large diameters or special materials; we confirm it in the quotation.

Can I replace an old Multi-Wing rotor with one from the current series?

Compatibility is checked case by case. Diameter, hub, number of blades, pitch angle, direction of rotation and the shaft interface all matter. Send the code engraved on the hub or blades, photos and the motor data, and we check the suitable item before the quotation.

What data do I need to send for a quotation on a D series fan?

We need the diameter, airflow and pressure, the voltage and frequency of the IEC motor, the working temperature, the anticorrosive protection required and whether the location is in an explosive atmosphere zone (ATEX). Also send the mounting position, so the housing length can be determined.

How do I request a Multi-Wing quotation?

Send the Multi-Wing code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote