For ruck Ventilatoren we quote duct, rectangular duct, roof and casing fans from the ETALINE, KVR, DVN and MPC series, Venturion radial fans, JetFan CPA and CPC and compact units ETA K and ROTO K with heat recovery.
Headquarters: Boxberg, Germany
Who is ruck Ventilatoren and what does it make?
ruck Ventilatoren is a German manufacturer of fans and ventilation units, based in Boxberg. The range covers round duct fans and rectangular duct fans, roof fans, casing fans, Venturion industrial radial fans, AXIALINE axial fans, JetFan for air guidance in garages and compact ventilation units with heat recovery. They are used for ventilating industrial and public buildings, for extracting air and smoke and for cooling machinery.
The round duct fans ETALINE, ETAMASTER, RS and ISOR have flows from 1990 to 23,140 m³/h, and the rectangular duct fans KVR, KVRI, EMKI, ELKI and KVT between 9660 and 14,960 m³/h. DHA, DVA, DHN, DVN, DVNI, DHL and DVL are fitted on the roof, and MPC, MPX, MPC T, MPC TI and MPS in a casing, with flows between 6700 and 22,870 m³/h. Some models are designed for flue gases (classes F300 and F400), and DHN, DVNI, DVN, MPC TI, MPC T and MPS work up to 200 °C.
Venturion is a family of standardised radial fans, in sizes from 250 to 1120 mm, with continuous operation between −20 and 130 °C, made of steel, with variants in aluminium or stainless steel. The compact units ETA K, with a counterflow exchanger, and ROTO K, with a rotary exchanger, recover heat from the exhaust air. ETA K H covers between 410 and 7372 m³/h, and ROTO K H between 1144 and 20,138 m³/h. For a quotation, what matters is the flow, the pressure, the temperature and the installation location.
What do we supply from the ruck Ventilatoren range?
| Product | Description |
|---|---|
| Duct and rectangular duct fans | ETALINE, ETAMASTER, RS and ISOR for round ducts, KVR, KVRI, EMKI, ELKI and KVT for rectangular ducts. |
| Roof and casing fans | DHA, DVA, DHN, DVN and the others are free-standing on the roof, and MPC, MPX and MPS are casing fans. The variants MPC T, MPC TI, DHN and DVNI are for hot air. |
| Venturion and AXIALINE | Venturion is an industrial radial fan in sizes from 250 to 1120 mm, with 2-, 4- or 6-pole motors at 50 and 60 Hz. AXIALINE is an axial fan for underground garages, smoke extraction and industrial ventilation. |
| JetFan and units with heat recovery | JetFan CPA (axial) and CPC (radial) guide the air in garages. ETA K with a counterflow exchanger exceeds 90 % thermal efficiency, and ROTO K with a rotary exchanger exceeds 80 %, in floor or ceiling versions. |
Why ruck Ventilatoren?
- Duct, rectangular duct, roof and casing fans — the same range covers several types of installation
- Some models for flue gases, classes F300 and F400 — can work in smoke extraction installations
- Venturion between 250 and 1120 mm and from −20 to 130 °C — a standardised family for industrial ventilation
- Variants with EC motors in several series — consumption adapts to the flow required
- ETA K and ROTO K units with heat recovery — reduce the heat losses of ventilation
Which ruck Ventilatoren codes and series are requested most often?
| Code | Description |
|---|---|
| ETALINE | Diagonal round duct fan |
| ETAMASTER | Diagonal round duct fan |
| RS | Radial round duct fan |
| KVR | Radial rectangular duct fan |
| DVN | Roof fan, up to 200 °C |
| DHN | Roof fan for hot air |
| MPC | Casing fan |
| MPS | Casing fan, up to 200 °C |
| Venturion | Industrial radial fan, 250–1120 mm |
| AXIALINE | Axial fan for garages and buildings |
| CPA | Axial JetFan, classes F300 and F400 |
| CPC | Radial JetFan |
| ETA K | Compact unit with counterflow exchanger |
| ROTO K | Compact unit with rotary exchanger |
Where is ruck Ventilatoren equipment used?
- Industrial buildings — ventilation with radial and roof fans
- Public buildings — duct, roof and casing fans
- Garages and car parks — JetFan and AXIALINE for air guidance and smoke extraction
- Cooling of machinery and installations — Venturion
- Halls and offices — compact units with heat recovery
How do we supply ruck Ventilatoren in Romania?
We can quote ruck Ventilatoren duct, rectangular duct, roof, casing and Venturion radial fans, as well as compact units ETA K and ROTO K. For a correct quotation, send the series and the size from the nameplate or, for a new installation, the flow, the pressure, the air temperature, the type of installation, the voltage and whether the motor is EC. We order, with a usual lead time of 1–4 weeks. For configured units the lead time can be longer, and the exact date is given in the quotation.
Complete ventilation units are selected based on the flow, pressure and building data, and the configuration is confirmed in the quotation.
Frequently asked questions about ruck Ventilatoren
What are ETALINE, Venturion, AXIALINE and JetFan at ruck Ventilatoren?
ruck Ventilatoren, based in Boxberg, Germany, makes round duct, rectangular duct, roof and casing fans, Venturion radial fans, AXIALINE axial fans, JetFan for garages and compact ventilation units with heat recovery. The range serves industrial and public buildings.
How do I choose between a round duct fan and a rectangular duct fan?
Round duct fans, for example ETALINE or RS, are mounted on round ducts, and rectangular duct fans, for example KVR, on standardised rectangular ducts. Send the duct type or the duct dimensions, the flow and the pressure, and we check the suitable series.
Do you supply ruck Ventilatoren in Romania, and how fast?
Yes. ruck products are supplied to order, with a usual lead time of 1–4 weeks. An item can ship in 24–72 h when the item is in stock, locally or at the supplier. For configured units the lead time can be longer, and the exact date is given in the quotation.
Can I replace an older fan with a ruck series?
It can be checked if you send the nameplate, the mounting dimensions, the flow, the pressure, the voltage and the position of the inlet and discharge openings. Equivalence is confirmed only after the data sent has been analysed; you will find the result in the quotation. For ETA K or ROTO K, add the fresh air flow, the type of installation (floor or ceiling), the heating or cooling need and whether the unit is outdoors.
How do I request a ruck Ventilatoren quotation?
Send the ruck Ventilatoren code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: ruck Ventilatoren GmbH (manufacturer documentation)