For Vortice we quote industrial axial fans from the VORTICEL MPC-E, MP, E and A-E series, ATEX-marked fans from the E-ATEX series and NORDIK HVLS Hyperblade ceiling fans; the item is identified by the five-digit code, diameter and supply voltage.
Headquarters: Tribiano (Milan), Italy
Who is Vortice and what does it make?
Vortice has its historic headquarters in Tribiano, near Milan, in Italy, and works through its own subsidiaries in several countries. For industrial installations the relevant products are axial fans, that is, fans that move air along the axis of the rotor, at high flow rates and relatively low pressures. Alongside them there are fans with ATEX protection (the directive for equipment intended for potentially explosive atmospheres) and large-diameter ceiling fans.
The VORTICEL MPC-E series consists of medium-pressure fans with a long casing, for duct mounting, in diameters of 250–400 mm and with flow rates of 1,180–5,200 m³/h. The MPC-E 302 M model, code 42209, has a diameter of 300 mm, a single-phase motor of 220–240 V at 50 Hz and can run continuously in air at temperatures of up to 70 °C. The panel-mounted fans in the VORTICEL E, MP and A-E series cover diameters of 250–630 mm, and flow rates range from 765 m³/h on the compact A-E models to 14,500 m³/h on the MP series.
The E-ATEX series includes models of 250–600 mm, with flow rates of 1,000–6,900 m³/h, marked ATEX II 2G/D for gases and dusts. The model with code 40320 has temperature class T3, that is, surfaces not exceeding 125 °C, a motor with IP65 protection and a permitted ambient temperature between −20 °C and +40 °C. The NORDIK HVLS ceiling fans (high volume, low speed) have an EC motor, an electronically commutated version; on the 7 m model, supplied three-phase at 200–480 V, the motor protection is IP65, and the fan stops automatically on the signal from the fire alarm system.
What do we supply from the Vortice range?
| Product | Description |
|---|---|
| VORTICEL MPC-E, axial fans for ducts | Medium-pressure fans with a long casing, in diameters of 250–400 mm and with flow rates of 1,180–5,200 m³/h. The impeller has six blades of reinforced polypropylene, dynamically balanced, and the motor is single-phase. Code 42209 corresponds to the MPC-E 302 M model, with a diameter of 300 mm. |
| VORTICEL E, MP and A-E, panel-mounted axial fans | The E series is low-pressure, in diameters of 250–600 mm, with flow rates of 1,000–7,700 m³/h. The MP series is medium-pressure, with flow rates of 1,150–14,500 m³/h, and the A-E and A-E ES series are compact, with flow rates starting from 765 m³/h. They are chosen by the flow rate required. |
| E-ATEX, axial fans for explosive atmosphere zones | Panel-mounted fans in diameters of 250–600 mm, with flow rates of 1,000–6,900 m³/h, marked ATEX II 2G/D. Model 40320 has a 230 V single-phase motor, IP65 protection, temperature class T3 and works at ambient temperatures between −20 °C and +40 °C. |
| NORDIK HVLS Hyperblade, ceiling fans | Large-diameter ceiling fans, with anodised aluminium blades fitted with winglets, an EC motor and integrated electronics with an RS485 Modbus interface for building automation systems. Model 61201, with a diameter of 7 m, has a three-phase motor of 200–480 V. |
Why Vortice?
- Series of axial fans for ducts, with a long painted steel casing — suited where air has to be pushed through ductwork, not just exhausted through a wall
- Panel-mounted fans in diameters of 250–630 mm — a diameter and flow step for each pressure level, from the low-pressure E series to the medium-pressure MP series
- E-ATEX series with II 2G/D marking and temperature class T3 — for ventilating spaces where flammable gases or dusts may occur
- HVLS ceiling fans with EC motor and IP65 protection — air circulation over large hall areas, with speed control through a 0–10 V analogue input
- Five-digit code on each model — the item is identified exactly by code, without going through similar trade names
Which Vortice codes and series are requested most often?
| Code | Description |
|---|---|
| MPC-E | Axial fan for ducts, medium pressure, 250–400 mm |
| 42209 | Model MPC-E 302 M, nominal diameter 300 mm, single-phase motor |
| VORTICEL E | Panel-mounted axial fan, low pressure, 250–600 mm |
| VORTICEL MP | Panel-mounted axial fan, medium pressure, 250–600 mm |
| VORTICEL A-E | Compact panel-mounted axial fan, 250–630 mm |
| VORTICEL A-E ES | Compact panel-mounted axial fan, codes 41220–41231 |
| E-ATEX | Axial fan for potentially explosive atmosphere zones, codes 40320–40333 |
| 40320 | Model E 254 M, ATEX II 2G/D, 250 mm, IP65 motor |
| NORDIK HVLS HYPERBLADE | Large-diameter ceiling fan with EC motor, 3–7 m |
| 61201 | Model NORDIK HVLS Hyperblade 700, three-phase motor of 200–480 V |
Where is Vortice equipment used?
- Production and logistics halls — HVLS ceiling fans for mixing air over large areas
- Local and general ventilation of workshops — panel-mounted axial fans for extracting contaminated air
- Installations with air ducts — axial fans for ducts from the MPC-E series
- Zones with flammable gases or dusts — E-ATEX fans with II 2G/D marking
- Technical spaces and machinery rooms — ventilation with versions in diameters of 250–630 mm
How do we supply Vortice in Romania?
From the Vortice industrial range we can quote axial fans for ducts, panel-mounted fans, E-ATEX models and NORDIK HVLS ceiling fans. For an accurate quotation, the useful data are the five-digit code of the model, the diameter, the flow rate and pressure required, the voltage and number of phases of the supply, and the air temperature in the installation. For ATEX models, also send the marking from the nameplate. Products are supplied to order, usually in 1–4 weeks; products can ship in 24–72 h when the item is in stock, locally or at the supplier. The exact lead time is confirmed in the quotation.
For large-diameter ceiling fans, the type of fixing and the stabilising accessories are determined according to the mounting location, based on the data you send.
Frequently asked questions about Vortice
What industrial fans are in the Vortice range?
The industrial range includes axial fans for ducts from the VORTICEL MPC-E series, panel-mounted axial fans from the VORTICEL E, MP and A-E series, E-ATEX fans for potentially explosive atmospheres and large-diameter NORDIK HVLS ceiling fans.
How do I choose between the E series, the MP series and the MPC-E series?
Start from the flow rate and the static pressure in the installation. The E series is low-pressure with flow rates of 1,000–7,700 m³/h, the MP series is medium-pressure and reaches 14,500 m³/h, and the MPC-E is mounted in a duct, in diameters of 250–400 mm. Send us the flow rate, the pressure loss and the duct diameter.
Do you supply Vortice fans in Romania and how fast?
Yes. Industrial models are supplied to order, usually in 1–4 weeks. A model can ship in 24–72 h when the item is in stock, locally or at the supplier. Depending on the model and the specification, the lead time may be longer; we confirm it in the quotation.
Can I replace an existing Vortice fan with one from the E-ATEX series?
The replacement depends on the classified zone and the marking required on site. The E-ATEX series carries the ATEX II 2G/D marking, with temperature class T3. Send us the code and marking of the old fan, and the zone from the explosion protection documentation, and we check the suitable version.
What data do I need to send for a quotation on a NORDIK HVLS ceiling fan?
We need the diameter you want or the area to be covered, the mounting height, the supply voltage available (on the 7 m model, the motor is three-phase, 200–480 V), the type of speed control and whether there is a risk of gusts or vibration, in which case the optional stabilising tie rod is added.
How do I request a Vortice quotation?
Send the Vortice code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.